Business Type:
Manufacturer/Factory
Establishment:
2012
R&D Capacity:
ODM, OEM, Other
OEM/ODM Service
Sample Available

Extinguishant Control System, Extinguish Fire System, Extinguish Control Panel manufacturer / supplier in China, offering Fire Fighting Fire Alarm System with Fire Extinguishant Control Panel, AC220V Combustible Gas Detector Gas Alarm for Home Kitchen Using, Standalone Town Gas Detector LPG Leakage Gas Alarm Coal Gas Leakage Detector and so on.

1
    YRS
General Supplier
Supplier Homepage Security & Protection Fire Control Fire Extinguisher China Extinguishant Control System Fire Suppression Systems Fire Fighting Panel

China Extinguishant Control System Fire Suppression Systems Fire Fighting Panel

Get Latest Price
Min. Order / Reference FOB Price
1 Pieces US $170.00/ Pieces
Local Area: Shenzhen, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Type: Fire Alarm Host
Function: Networked
Usage: Auto, Fire, Smoke

The automatic extinguisher control panel is designed in accordance with European standards EN54-2 and EN54-4 Fire Detection and Fire Alarm systems - Control and Indicating Equipment and EN12094-1 Fixed firefighting systems - Components for gas extinguishing systems - Part 1: Requirements and test methods for electrical automatic control and delay devices.
The control equipment is a combined fire alarm control panel and extinguishing system and has four detection zones, any or all of which are capable of contributing to the extinguishant release decision.
Control panels have an integral, mains powered battery charger and power supply designed in accordance with the requirements of EN54-4.In addition to the requirements of EN54-2 the control panel has the following facilities:
to allow the automatic resetting of zones in alarm for testing purposes. EN54-2 Section 10 option with requirementsof fire alarm devices (sounders) so that an alarm may be verified before a premises is evacuated. EN54-2 Section 7.11 option with requirements.
to enable an audible warning to be sounded throughout premises upon the detection of a fire condition or the operation of a manual call point. EN54-2 Section 7.8 option with requirementsIn addition to the requirements of EN54-2, all control panels have voltage free relay contacts for fire and local fire which operate upon a fire condition. These are to be used for local control and signaling.In addition to the requirements of EN12094-1 the control panel has the following facilities:
of up to 75seconds. EN12094-1 Section 4.17 option with requirements.to indicate the released condition. EN12094-1 Section 4.18 option with requirements.by way of a low pressure switch input. EN12094-1 Section 4.19 option with requirements.
to enable the extinguishant delay time to be extended. EN12094-1 Section 4.20 option with requirements.to deactivate the releasing output after a set period of time. EN12094-1 Section 4.21 option with requirements.to disable the release of extinguishant via automatic detection devices. EN12094-1 Section 4.23 option with requirements.Triggering of equipment outside the system by way of first and second stage contacts, extract fan output etc. EN12094-1 Section 4.26 option with requirementsActivation of alarm devices with different signals to indicate pre-discharge and released warnings using different sounds. EN12094-1 Section 4.30 option with requirements.2. Safety
Suppliers of articles for use at work are required under section 6 of the Health and Safety at Work act 1974 to ensure as reasonably as is practical that the article will be safe and without risk to health when properly used.
An article is not regarded as properly used if it is used 'without regard to any relevant information or advice' relating to its use made available by the supplier.
This product should be installed, commissioned and maintained by trained service personnel in accordance with the following:(i) IEE regulations for electrical equipment in buildings
(ii) Codes of practice
(iii) Statutory reqPneumatic Tools uirements
Industrial Customized Service (iv) Any instructions specifically advised by the manufacturerAccording to the provisions of the Act you are therefore requested to take such steps as are necessary to ensure that you make any appropriate information about this product available to anyone concerned with its use.
This equipment is designed to operate from 230V/50Hz mains supplies and is of class 1 construction. As such it mustbe connected to a protectivPower Transmission & Transformer e earthing conductor in the fixed wiring of the installation and a readily accessible double pole disconnect device meeting the requirements of EN60950/IEC950 which disconnects live and neutral simultaneously shall be incorporated in the fixed wiring.
Switch disconnect devices such as MK Sentry 63A or similar are suitable for this.
Failure to ensure that all conductive accessible parts of this equipment are adequately bonded to the protective earth will render the equipment unsafe.
This control panel is environmental class A and is designed for indoor use only at temperatures between -50ºC(+/- 3) and +400ºC(+/- 2) and with a maximum relative humidity of 95%.
The IP rating for the enclosure is IP30.
Operation outside of these limits may render the equipment unsafe.

Conventional Fire Fighting Panel

Key Specifications/Special Features

Four Style B (Class B) Initiating Device Circuits (IDCs).All zones accept two-wire smoke detectors and any normally-open contact devices.One built-in Fire Fighting Ouput.24-volt operation.Resettable four-wire smoke detector power @ 500 mA.Non-resettable power @ 500 mA.One-man walk-test programmable for silent or audible test.Disable/Enable control per IDC.Reverse polarity protection.
tallic-Processing-Machinery-p3747/">metallic Processing Machinery