Extinguishant Control System, Extinguish Fire System, Extinguish Control Panel manufacturer / supplier in China, offering Fire Fighting Fire Alarm System with Fire Extinguishant Control Panel, AC220V Combustible Gas Detector Gas Alarm for Home Kitchen Using, Standalone Town Gas Detector LPG Leakage Gas Alarm Coal Gas Leakage Detector and so on.

1
    YRS
General Supplier
Supplier Homepage Instruments & Meters Detector Fire Alarm & Smoke Detector China Alarm System Fire Alarm Control Panel Addressable Fire Alarm System

China Alarm System Fire Alarm Control Panel Addressable Fire Alarm System

Get Latest Price
Min. Order / Reference FOB Price
1 Pieces US $450.00/ Pieces
Local Area: Shenzhen, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Type: Smoke Detectors
Anti-theft Alarm System Approach: Active
Anti-Theft Alarm System Type: Sound and Light Alarm
Installation and Operation MaLifting Equipment nualFW6000 Fire Alarm Control Panel
FW6000 Intelligent Fire Alarm Control Panel (FACP) Oscillator is the new-generation fire alarm control unit designed by our company for applications in small and medium projects. It is wall-mounted type and has the advantages of powerful function, high reliability and flexible configuration. The panel is equipped with a LCD monitor to display all the information on fire alarms, faults and various operations, which can be printed out by the built-in printer. FW6000 is a one-loop control panel with maximum 240 points, which can work together with all FW 3 series field devices. Note: COM port needs grounding
1,(Monitoring Start Output)HJ: Active NO terminal to Fire alarm routing device (use jumper to switch
between passive and active), which will close to connect +24V output after started (each points with a
max output current of 100mA)
2,(Monitoring Start Output)SG: Active NO terminal to Sounder Strobe (Both active and passive modes,
use jumper to switch between passive and active), which will close to connect +24V output after
started (with max output current of 100mA for each direct-start point)
3,BUS: Non-polarity two-wire bus terminal
4,linkage power supply output: 24VDC(Max output current 1A)
5,Main board power supAlarm & Security Systems ply input: 220VAC
6,Grounding Terminal: Grounding
2.4 Technical Specifications
2.4.1 Power SupplyIndustrial Humidifier & Dehumidifier :
AC power: Nominal operation voltage 220VAC (187VAC ~ 242VAC)
Standby Battery: 2 x 12V/12AH
2.4.2 Operating Environment:
Temperature: 0ºC~+40ºC
Relative Humidity: ≤95%, non-condensing
2.4.3 Capacity: One loop with maximum 240 devices
2.4.4 Display: LCD 128x64 lattice graphic
2.4.5 Dimension: (LenResistor & Potentiometer gth xWidth xHeight):330.0mmx130.0mmx400.0mm
2.4.6 Wiring requirement
1,Recommend to use RVS2x1.0MM2 or RVS2x1.5MMtwisted wire for CAN communication wire and bus
wire, while use RVSP2x1.0mm2 at the high interference environment.
2,Not allowed to lay CAN communication wire and telephone line together with bus wire inside the same
multi-core cable.