Home Inverter, Inverter, Power Inverter manufacturer / supplier in China, offering Pure Sine Wave Inverter Home Inverter Power Inverter with UPS Function for TV, Light, AC, Fan, Bulb and Fridge Use, 220V 230V 240V Digital LCD Online UPS System 1k - 3kVA for Home and Office Use, High Frequency Online UPS Power 6kVA - 10kVA with Three Level Inverter Tech and 94% Efficiency and so on.

1
    YRS
General Supplier
Supplier Homepage Electrical & Electronics Power Supply & Distribution UPS Transformerless High Frequency Online UPS 10K - 80kVA with IGBT Tech

Transformerless High Frequency Online UPS 10K - 80kVA with IGBT Tech

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $500.00/ Piece
Local Area: Shenzhen, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Brand: Upsen
Phase: Three Phase
Type: On-line
Protection: Overvoltage

Transformerless High Frequency online UPS 10K- 80KVA with IGBT TechQuick View
1: China UPS with good quality and low price, same quality like APC, Eaton, MGE UPS.
2: 3 Phase UPS with 50Hz / 60Hz Frequency and 380V / 400V / 415VAC Input and output
3: Triphase UPS withEmergency power off function (EPO)
3: UPS with SNMP , USB , RS232 Ports
4: UPS with Parallel Redundancy Function
UPS Key Features True double-conversion.DSP technology guarantees high performance.Output power factor 0.8.Active power factor correction in all phases.50Hz/60Hz frequency converter mode.Accepts dual-mains inputs.Generator compatible.SNMP+USB+RS-232 multiple communications.3-stage extendable charging design for optimized battery performance.Adjustable battery numbers.Maintenance bypass available.Optional N+X parallel redundancy.
Technical SpecificationModel33Q10KL33Q 20KL33Q 30KL33Q 40KL33Q 60KL33Q 80KLCommentsInputInput voltageRated voltage380VAC/220VAC380VACPhasethree phase with groundTurn on voltage range(120±5~274±5)VAC(207±9~475±9)VACBypass voltage range(60±5~300±5)VAC(105±9~518±9)VACCould be adjusted by software.Bypass
low loss60VAC~220VAC(default 60VAC)105VAC~380VAC
(default 105VAC)Bypass low comebackLow loss +5VACLow loss +17VACBypass high loss220VAC~300VAC(default 300VAC)380VAC~475VAC
(default 475VAC)Bypass high comebackHigh loss -5VACHigh loss -17VACLine low loss
/comeback(120±5) VAC /(140±5) VAC(207±9) VAC /(242±9)VACload≤50%(140±5) VAC /(160±5) VAC(242±9) VAC /(276±9)VAC50%<load ≤90%(160±5) VAC /(175±5) VAC(276±9) VAC /(302±9)VACload>90%Line high loss/comeback(275±5)VAC/(260±5)VAC(475±9)VAC/(449±9)VACInput frequencyRated frequency50HzFrequency
low loss(40~49) ±0.2Hz(default:46Hz)Could be adjusted by software.Frequency
low comebackFrequency low loss +0.5HzFrequency
high loss(51~60)±0.2Hz(default:54Hz)Frequency high comebackFrequency high loss -0.5HzInput power factorInput power factor> 0.9933Q 10-40KL:220VAC,full R load
33Q 60-80KL: 380VAC,full R loadGeneratorSupport generator inputGenerator rating≥2*UPS ratingInput currentRated current14A28A42A67A80A105AInput THDI<= 10%Output protectionRating protection32A
Breaker50A
Breaker60A
Breaker80A
Breaker100A
Breaker125A
BreakerOutput powerVA/watt10KVA/8KW20KVA/16KW30KVA/24KW40KVA/32KW60KVA/
48KW80KVA/
64KWRated voltage220VAC380VACSine waveVoltage range200/208/220/230/240VAC345/359/380/397/415 VAC33Q 10-40KL: Could be adjusted by software. 10% derating for 208VAC/200VAC.
33Q 60-80KL: Could be adjusted by software. 10% derating for 345VAC/359VAC.Voltage regulation±1%Voltage distortion≤5%≤10%Full RCD load≤3%Full R loadDC offset≤200mVTransient response≤9%R load0%~100%~0%≤6%R load 20%~100%~20%Transient recovery≤60ms voltage recovery to 90%Full RCD loadBypass output
before turn-onYESCrest ration3:1Output frequency rangeNormal mode1,Same as input frequency(46Hz~54Hz)
2,50Hz(Input frequency>54Hz or Input frequency<46Hz)Battery mode(50±0.1) HzSlew rate1 Hz/SecEfficiencyNormal mode> 93%> 90%Battery mode> 90%> 90%OverloadNormal mode
/battery modeOverload warning only105%±5%≤load1min,then transfer to bypass and alarm.105%±5%30S,then transfer to bypass and alarm.125%±5%300mS, then transfer to bypass and alarm.load>150%±5%Automatically retransferYESShort protectionNormal/
battery modeYESTransfer timeNormal to battery mode0mSBattery to normal mode0mSNormal to bypass mode<4mS0mSBypass to normal mode<4mS0mSBattery and chargerBatteryRated voltage192VDC240VDC192VDC*2192VDC*2480VDCType/RatingBattery quantity162016*216*240Backup timeProtectionLow alarm voltage /comebackvoltage(180.8V±4V)/ (188.8V±4V)(226V±4V)/ (236V±4V)(180.8V±4V)/ (188.8V±4V)(226V±4V)/ (236V±4V)(452V±4V)/ (472V±4V)33Q 30KL use twoShutdown voltage/ comeback voltage160V±4V/168V±4V(200V±4V)/ (210V±4V)160V±4V/
168V±4V(200V±4V)/ (210V±4V)(400V±4V)/ (420V±4V)DC protectionOvercharge protection/ comeback voltage(249.6V±4V)/
(216V±4V)(312V±4V) (270V±4V)(249.6V±4V)/ (216V±4V)(312V±4V) (270V±4V)(624V±4V) (540V±4V)Leakage current< 500uAOver discharge protection14.5hCould be set by softwareBattery testBattery weakYESBattery faultYESChargerOutput voltage(219.2±3)VDC(277±3)VDC(219.2±3)VDC(277±3)VDC(554±3)VDCCharge timeDepends on the external battery capacityCharge current7.5A6A5A4A10AInterfaceAlarm silenceYESDC power
turn-onYESAutomatically retransferYESAudio alarmBattery modeBeep/4sBattery low/
charger faultBeep/1sUPS faultContinue beepOverloadBeep/1sBypass modeBeep/2MinL/N inverseBeep/2MinCommunicationRS232 interfaceYESIntelligent slotYESMonitor softwareAppending with UPSCoolingForce air coolingDisplayLCD/LED displays UPS statusEnvironmentWork temperature0ºC~40ºCAltitude<1000mAudible noise≤60dBStorage temperature-15ºC~45ºCWork humidity20%~95%StandardEMSESDIEC61000-4-2Level4RSIEC61000-4-3Level3EFTIEC61000-4-4Level4SurgeIEC61000-4-5Level4EMIConductedEN55022Class ARadiatedEN55022Class ASafetySafetyGB4943-2001/IEC62040-1Machinery featuresSizeOutline dimension and net weightL*W*H (mm)710*260*717840*515*1135Net weight(Kg)45/9350/98195208Optional functions60HzOptionalSet by softwareConverter modeOptionalSet by softwareECOOptionalOptionalAvailable and set by softwareEPOOptionalOptional*Specification is subject to change without further notice