Intelligent Dry Type Transformer Monitor is designed for the safe operation of dry transformer. It can automatically operates the fan's relay according to the temperature.By comparing current temperature with pre-selected temperature,monitor operates the alarm,trip relays to keep the transformer safe operation. Technical index:
Rail transit fiber optic temperature controllerFluorescent fiber optic sensing probeAmbient temperature:-20ºC~+55ºCMaterial:No metal material, quartz fiberAmbient humidity:< 95% (25ºC)Probe size:3mm in diameter;
Standard equipped with 3M(Customizable length)Working voltage:AC 220V (+10%,-15%)Immune electromagnetic interference
Withstand power frequency voltage 100KVWorking frequency rate:50Hz OR 60Hz(±2Hz)Range of measurements:-40.0ºC~200.0ºCMeasurement accuracy:±1%FSResolution ratio:0.1ºCFan output total capacity:9A/250VACControl output capacity:5A/250VAC;5A/30VDC(resistivity)
Standard of Execution:
Production standardsJB/T7631-2005"Electronic temperature controller for Transformers"Industry standardsAdoption of accreditation standards:ISO9001:2008International Quality Management System CertificationPass the test standard:IEC61000-4:1995 International standardGB/T17626-2008"Electromagnetic compatibility test and measurement techniques"standard Special temperature controller for rail transit1.Monitor up to three dry-type transformer windings;2.Built-in fan control, fan exerciser;3.Each temperature sensor has temperature compensation function4.When the monitor is turned off, the temperature value can be saved.5.LCD liquid crystal display, LED display lamp, operation button;6.Clock function;7.Alarm function for transformer door cabinet opening;8.1 pair of over-temperature alarm terminals (1 normally open, 1 normally closed);9.3 sets of over-temperature trip terminals (3 normally open and 3 normally closed) are provided;10.1 set of fan remote transmission nodes (1 normally open, 1 normally closed);11.1 set of temperature controller power off alarm contacts (1 normally open, 1 normally closed);12.1 set of temperature controller fault alarm contacts (1 normally open, 1 normally closed);13. RS485 communication function, MODBUS-RTU protocol;Custom function1.According to customer demand, provide 4 channel 4~20mA analog current output function;2.According to customer requirements, provide fan fault judgment function, provide two fan fault alarm contacts ;3.1-8channel optical fiber temperature measurement4.Many kinds of communication: industrial networking module, ethernet communication, profibus communication module and so on.5.According to customer needs,provide alarm function for winding and iron core temperature rise rate.
Product Features:Optical Fiber Temperature Controller for Rail Transit
Embedded installation
ModelNumber:SR-TL series
Outline dimension:442x558x140(mm)
Front view lateral view