Automatic Transfer Switch, ATS, Change Over Switch manufacturer / supplier in China, offering PC Class ATS Change-Over Switch 16-3200A Automatic Transfer Switch for Generator, Sq5 Manual Changeover Switch ATS Electrical Changeover Switch, 20ka-40ka DC500V Solar DC Surge Protector and so on.
Min. Order / Reference FOB Price | |
---|---|
1 Piece | US $1.50/ Piece |
Local Area: | Wenzhou, Zhejiang, China |
---|---|
R&D Capacity: | OEM, ODM, Other |
Payment Terms: | LC, T/T, PayPal, WesternUnion, Small-amountpayment |
Brand: | Suntree/OEM |
---|---|
Breaking Capacity: | Low Voltage Circuit Breakers |
Operation: | Electric Type |
Speed: | Normal Type Circuit Breaker |
Technical DataIEC 898Standards1P/2P/3P / 4PPolesCMagnetic tripping characteristics6 10 16 20 25 32,40,50,63ARated current(A)6kARated short-circuit capacity(Icn):DC250V DC550V DC750V DC800V DC1000V DC1200VRated voltage6kVRated withstand voltage (Uimp):1000Rated insulation voltage(Ui):YesContact position indication3Energy limiting class:>2000Electrical Life:>1500Mechanical Life:Screw terminalConnection terminal:Pillar terminal with clamp
1~16mmConnection capacity:Symmetrical DIN rail 35mmInstallation:Panel mounting
OF: Auxiliary contactAccessories:FB: Auxiliary alarm
QY: under/over volage protector
FL: Shunt release
TestTypeCurrentStart StateTrip / Not-trip
Time LimitExpected
ResultNoteac1.05 lnColdt ≥1hNot-trip
bc1.30 lnFoollows test at<1hTripThe current will rise to expected value within 5Scc7 lnColdt ≥0.1sNot-trip
dc15lnColdt<0.1sTrip
Operating Voltage (Ue)1P=125V DC or 250V DC, 2P=550V DC or 800V DC
3P=750V DC or 800V DC, 4P=1000 V DC or 1200V DCRated insulation voltage (Ui)12V-1200 VDCBreaking capacity (Icu)10 kAImpulse voltage (Uimp)6 kAElectrical connectionBy the bottom for In and OutNumber of poles1P, 2P, 3P, 4PStandardsIEC 60947-2
EN 60947-2
SAA
CE
TUV
Rated service breaking capacity (Ics)100 % of the IcuEndurance (O-C)Electrical1,500 cycles (where L/R=2 ms)Mechanical20, 000 cycles Mechanical20, 000 cyclesDegree of pollution2CategoryA (no delay in accordance with IEC / EN 60947-2 standards)Degree of protection
(IEC 60529)IP40TropicalisationRelative humidity: 95 % at 55°C in accordance with
IEC 60068-2 and GB 14048.2 standardsTemperatureOperating-25°C to 70 °CStorage-40°C to 85°C
TypeDZ47 C45, C45NNumber of poles1P, 2P, 3P, 4PRated Current(A)1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63ABreaking Capacity(A)6000/ 4500Rated Voltage(V)230/400VRated Frequency(Hz)50/60HzEndurance≥4000Circumstance Temp.(°C)-5°C ~ +40°CElectrical Life≥6000Mechanical Life≥20000Terminal protectionIP20
C65 DPN circuit breaker MCBApplication:TypeC65-DPNNumber of poles1PRated Current(A)1, 2, 3, 4, 6, 10, 16, 20, 25, 32ABreaking Capacity(A)4500Rated Voltage(V)220/ 240VRated Frequency(Hz)50/60HzEndurance≥4000Tripping characteristicsB 3In ~ 5In; C 5In ~ 10In
C65 or C60 circuit breaker MCBApplication:TypeC65 C60Number of poles1P, 2P, 3P, 4PRated Current(A)1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63ABreaking Capacity(A)6000/ 4500Rated Voltage(V)230/400VRated Frequency(Hz)50/60HzEndurance≥4000Circumstance Temp.(°C)-5°C ~ +40°CElectrical Life≥6000Mechanical Life≥20000Terminal protectionIP20
NC100 circuit breaker MCBApplication:TypeNC100Number of poles1P, 2P, 3P, 4PRated Current(A)32, 40, 50, 63, 80, 100, 125ABreaking Capacity(A)10000Rated Voltage(V)230/400VRated Frequency(Hz)50/60HzEndurance≥4000Circumstance Temp.(°C)-5°C ~ +40°CElectrical Life≥6000Mechanical Life≥20000Terminal protectionIP20
DRNL RCD 32A 30mA 1p+N rcbo residual current breaker 4.5KA 6KAair reaches the highest temperature +40°C ,
the average minimum temperature when it is the wettest can not exceed 25°C Relative humidity not exceeding 90%.Installation conditions:Magnetic field outsid the installation place can not exceed 5 timesof the site of terrestrial magnetism in all
directions.Normally speaking,RCBO should be mounted vertically .If the operation handle puts through power source upward,there should
be no notable impact and vibration in the installation place.LeakAge protection function of RCBO is tested and adjusted by the manufacture,users can not open the products at random during usage.
After using RCBO for a certain time(normally one month) , test button should be pressed noce in a state of making thecircuit to check
whether the function of RCBO is normal and reliable(press test button once, the RCBO can break off noce) . If abnormal, it should beunloaded and sent to the manufacturer to repair.RCBO can not be wetted or soaked by rain,snow or water during the course ortransportation storage and usage.
Technical DataDRNL 1P+NStandardsAS/NZS 61009 - 1Magnetic tripping characteristicsB,CResidual tripping characteristicsA , ACRated current(A)6, 10, 16, 25, 32Rated residual current10mA, 30 mA, 100mACalibration temperature30°CRated voltage 1P240VFrequency50/60Maximum service voltage264Tripping Duration:Instaneous<0.1sPower supplyTop or bottomSelectivity class3Residual making and breaking capacity2000AShort circuit capacity6000A/4500AIsolation application (IEC 60947-2)YesInsulation resistance (Mohm)1,000Insulation voltage (V)500Dielectric rigidity (V)2,500Vibration resistance1.5gEndurance (operations) electrical>6,000mechanical>20,000Protection degree outsideIP20inside enclosureIP40Self extinguishing degree (UL 94)V2Tropicalisation (IEC 60068-2)+55°C/95% RHOperating temperature-5/+55°CStorage temperature-25/+70°CTerminal capacity (top & bottom) min / max1-16mmTerminal torque (top / bottom)3Busbar systemsYesAccessoriesNoDimensions (mm)72(H)82(L)18(W)Weight (g)105
TypeSL7Number of poles1P, 2P, 3P, 4PRated Current(A)1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63ABreaking Capacity(Icu)6KA/ 10KABreaking capacity of rated operating short circuit(Ics)7500ARated Voltage(V)230/400VRated Frequency(Hz)50/60HzCircumstance Temp.(°C)-5°C ~ +40°CElectrical Life≥8000Mechanical Life≥20000Type and tripping current scope of instantaneous releaseB 3In ~ 5In; C 5In ~ 10In; D 10In ~ 50InTerminal protectionIP20