Business Type:
Manufacturer/Factory
Business Range:
MCCB, Contactor, Circuit Breaker
Establishment:
2007
R&D Capacity:
OwnBrand, ODM, OEM
Terms of Payment:
LC, T/T, PayPal, WesternUnion, Small-amountpayment
Main Markets:
Europe, Southeast Asia, Middle East, Australia
OEM/ODM Service
Sample Available

Automatic Transfer Switch, ATS, Change Over Switch manufacturer / supplier in China, offering PC Class ATS Change-Over Switch 16-3200A Automatic Transfer Switch for Generator, Sq5 Manual Changeover Switch ATS Electrical Changeover Switch, 20ka-40ka DC500V Solar DC Surge Protector and so on.

1
    YRS
General Supplier
Supplier Homepage Electrical & Electronics Breaker & Protector Circuit Breaker China Acti9 IC65n 63 AMP Circuit Breaker Mini Circuit Breaker MCB

China Acti9 IC65n 63 AMP Circuit Breaker Mini Circuit Breaker MCB

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $1.50/ Piece
Local Area: Wenzhou, Zhejiang, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal, WesternUnion, Small-amountpayment
Brand: Suntree/OEM
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Speed: Normal Type Circuit Breaker
SL7-63 Mini Circuit Breaker AC MCB 1 pole 2 pole 3 pole SAA TUV
DC1200V 63A DC Circuit breaker for solar switch has passed IEC, TUV, CE certificate
DC circuit breaker's Application
SL7-63 Series DC1200V 63A DC Circuit breaker, apply to rating current 63A or less,
It is mainly used for the overloading and short circuit protection in DC distribution system
equipment and electric equipment. It can be widely used in electric, post, traffic, mining
enterprise and different kinds of fields. In present China, our products in the case grade rating
voltage is highest compared to the same products.
Standard
Products according IEC60947, GB14048.2, IEC60898.2 AS/NZS60898.1, AS/NZS60898.2, AS/NZ61009
Standard.

Technical DataIEC 898Standards1P/2P/3P / 4PPolesCMagnetic tripping characteristics6 10 16 20 25 32,40,50,63ARated current(A)6kARated short-circuit capacity(Icn):DC250V DC550V DC750V DC800V DC1000V DC1200VRated voltage6kVRated withstand voltage (Uimp):1000Rated insulation voltage(Ui):YesContact position indication3Energy limiting class:>2000Electrical Life:>1500Mechanical Life:Screw terminalConnection terminal:Pillar terminal with clamp
1~16mmConnection capacity:Symmetrical DIN rail 35mmInstallation:Panel mounting
OF: Auxiliary contactAccessories:FB: Auxiliary alarm
QY: under/over volage protector
FL: Shunt release


Overload Characteristic

TestTypeCurrentStart StateTrip / Not-trip
Time LimitExpected
ResultNoteac1.05 lnColdt ≥1hNot-trip
bc1.30 lnFoollows test at<1hTripThe current will rise to expected value within 5Scc7 lnColdt ≥0.1sNot-trip
dc15lnColdt<0.1sTrip


The SL7-63 is a DC circuit breaker
dedicated to multi string photovoltaic nstallations.
This circuit breaker is designed to protect the cables located between each string
of photovoltaic modules and the photovoltaic inverter against overloads and short
circuits (see application diagram).
Combined with a switch , the SL7-63 will be installed in a string
PV protection enclosure at the end of each string of photovoltaic modules.
It can be locked (by a padlocking device) in OFF position as a safety measure for
removal of the PV inverter.
Since a fault current can flow in the reverse direction to the operating current,
the SL7-63 can detect and protect against any bidirectional current.
To ensure the safety of the installation, it is necessary,
depending on the various types of application, to combine the SL7-63 with:
a residual current device at the AC end
a fault passage detector (insulation monitoring device) at the DC end
an earth protection circuit breaker at the DC end
In all cases, fast action on site will be required to clear the fault
(protection not ensured in the event of a double fault).
SL7-63 is not polarity sensitive: (+) and (-) wires can inversed without any risk.
The SL7-63 is: delivered with three inter-pole barrier to provide increased isolation distance between two adjacent connectors.

SL7-63 DC MCB Main characteristics

Operating Voltage (Ue)1P=125V DC or 250V DC, 2P=550V DC or 800V DC
3P=750V DC or 800V DC, 4P=1000 V DC or 1200V DCRated insulation voltage (Ui)12V-1200 VDCBreaking capacity (Icu)10 kAImpulse voltage (Uimp)6 kAElectrical connectionBy the bottom for In and OutNumber of poles1P, 2P, 3P, 4PStandardsIEC 60947-2
EN 60947-2
SAA
CE
TUV

Technical data
Position contact indication - suitability for isolation according to IEC/EN 60947-2 standard.
The presence of the green strip guarantees physical opening of the contacts and allows operations
to be performed on the downstream circuit in complete safety.
Increased product service life thanks to fast closing independent of the speed of actuation of the toggle.
Pre-wired product: Input / Output on the same side.

Rated service breaking capacity (Ics)100 % of the IcuEndurance (O-C)Electrical1,500 cycles (where L/R=2 ms)Mechanical20, 000 cycles Mechanical20, 000 cyclesDegree of pollution2CategoryA (no delay in accordance with IEC / EN 60947-2 standards)Degree of protection
(IEC 60529)IP40TropicalisationRelative humidity: 95 % at 55°C in accordance with
IEC 60068-2 and GB 14048.2 standardsTemperatureOperating-25°C to 70 °CStorage-40°C to 85°C

SUNTREE also produce AC circuit breaker,pls kindly check:
DZ47 C45N circuit breaker MCBApplication:
DZ47 C45N series mini circuit breaker are used in lighting distribution system in dusty, commerce and
dwelling, and protecting fractional electric motors, And they also have many merits of high protective
grade (up to IP20), high break capacity, reliable sensitive action, convenient, multiple assembling,
long life etc. They are mainly adapted to the circuit of AC 50HZ, 230V in single pole, 400V in double,
three, four poles for protecting overload and short circuit, Meanwhile, they are also used in turning on
or off the electric apparatus and lighting circuit under the normal condition. DZ47 C45N Technical Data

TypeDZ47 C45, C45NNumber of poles1P, 2P, 3P, 4PRated Current(A)1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63ABreaking Capacity(A)6000/ 4500Rated Voltage(V)230/400VRated Frequency(Hz)50/60HzEndurance≥4000Circumstance Temp.(°C)-5°C ~ +40°CElectrical Life≥6000Mechanical Life≥20000Terminal protectionIP20

C65 DPN circuit breaker MCBApplication:
C65-DPN Series Miniature Circuit Breaker ,
the maximum breaking capacity of up to 4.5kA .
Mainly used in industry, construction, residential, energy and infrastructure construction, etc. C65 DPN circuit breaker MCB Technical Data

TypeC65-DPNNumber of poles1PRated Current(A)1, 2, 3, 4, 6, 10, 16, 20, 25, 32ABreaking Capacity(A)4500Rated Voltage(V)220/ 240VRated Frequency(Hz)50/60HzEndurance≥4000Tripping characteristicsB 3In ~ 5In; C 5In ~ 10In

C65 or C60 circuit breaker MCBApplication:
1)C65 series circuit breaker are used in lighting distribution system or motor distribution system for
protection overload and short-circuit in the system.
The product is neoteric in structure, light in weight, reliable and excellent in performance.
It has high breaking capacity, can trip quickly, and its case and items are adopted by high fire-resistant and shockproof plastics.
2)The product, with long life, is mainly used in AC 50Hz/60Hz single pole 230V or two, three,
four poles 400V circuit for overload and short-circuit protection as well as for unfrequent on-and-off switching electric equipment and lighting circuit in normal case. The products comply with IEC 60898.C65 C60 Technical Data

TypeC65 C60Number of poles1P, 2P, 3P, 4PRated Current(A)1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63ABreaking Capacity(A)6000/ 4500Rated Voltage(V)230/400VRated Frequency(Hz)50/60HzEndurance≥4000Circumstance Temp.(°C)-5°C ~ +40°CElectrical Life≥6000Mechanical Life≥20000Terminal protectionIP20

NC100 circuit breaker MCBApplication:
1)NC100 Series Miniature Circuit Breaker High Breaking Capacity is a small circuit breaker,
the maximum breaking capacity of up to 36kA Include NC100H/NC125H Miniature Circuit Breaker,
NC100LS small leakage protection circuit breaker and vigi NC100 accessories, etc.
2)Mainly used in industry, construction, residential, energy and infrastructure construction, etc.NC100 Technical Data

TypeNC100Number of poles1P, 2P, 3P, 4PRated Current(A)32, 40, 50, 63, 80, 100, 125ABreaking Capacity(A)10000Rated Voltage(V)230/400VRated Frequency(Hz)50/60HzEndurance≥4000Circumstance Temp.(°C)-5°C ~ +40°CElectrical Life≥6000Mechanical Life≥20000Terminal protectionIP20

DRNL RCD 32A 30mA 1p+N rcbo residual current breaker 4.5KA 6KA
Normal Operation ConditionsAmbient Air temperature:Ambient air temperature range from -5°C ~+40°C ,not exceeding 35°C averagely in 24 hours.Location:installation location can not exceed 2000 meters above sea level.Air conditons:Relative humidity in the installation palce can not exceed 50% when the

air reaches the highest temperature +40°C ,

the average minimum temperature when it is the wettest can not exceed 25°C Relative humidity not exceeding 90%.Installation conditions:Magnetic field outsid the installation place can not exceed 5 times

of the site of terrestrial magnetism in all

directions.Normally speaking,RCBO should be mounted vertically .

If the operation handle puts through power source upward,there should

be no notable impact and vibration in the installation place.LeakAge protection function of RCBO is tested and adjusted by the manufacture,

users can not open the products at random during usage.

After using RCBO for a certain time(normally one month) , test button should be pressed noce in a state of making the

circuit to check

whether the function of RCBO is normal and reliable(press test button once, the RCBO can break off noce) . If abnormal, it should beunloaded and sent to the manufacturer to repair.RCBO can not be wetted or soaked by rain,snow or water during the course or

transportation storage and usage.

Technical DataDRNL 1P+NStandardsAS/NZS 61009 - 1Magnetic tripping characteristicsB,CResidual tripping characteristicsA , ACRated current(A)6, 10, 16, 25, 32Rated residual current10mA, 30 mA, 100mACalibration temperature30°CRated voltage 1P240VFrequency50/60Maximum service voltage264Tripping Duration:Instaneous<0.1sPower supplyTop or bottomSelectivity class3Residual making and breaking capacity2000AShort circuit capacity6000A/4500AIsolation application (IEC 60947-2)YesInsulation resistance (Mohm)1,000Insulation voltage (V)500Dielectric rigidity (V)2,500Vibration resistance1.5gEndurance (operations) electrical>6,000mechanical>20,000Protection degree outsideIP20inside enclosureIP40Self extinguishing degree (UL 94)V2Tropicalisation (IEC 60068-2)+55°C/95% RHOperating temperature-5/+55°CStorage temperature-25/+70°CTerminal capacity (top & bottom) min / max1-16mmTerminal torque (top / bottom)3Busbar systemsYesAccessoriesNoDimensions (mm)72(H)82(L)18(W)Weight (g)105


1P+N RCBO DRNL Dimensions
SL7 AC Mini Circuit Breaker Application:
1)SL7 Circuit Breaker is applicable to protecting from overload and short circuit in the circuit of AC
50/60Hz, Rated voltage 230/400V, rated current 63A, it also can be used in switch the infrequent
operation of the circuit under normal conditions. It's mainly used in industry, commerce, high-rise buildings and residential houses and so on.
2)The Circuit breaker conforms to the requirement of overcurrent protective circuit breaker used in
home and similar fields of IEC60898:1995, IEC60947, GB10963-1999 CE
SAA TUV etc. standards, It has attained the electrical equipment safety certificate.SL7 AC Mini Circuit Breaker Technical Data

TypeSL7Number of poles1P, 2P, 3P, 4PRated Current(A)1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63ABreaking Capacity(Icu)6KA/ 10KABreaking capacity of rated operating short circuit(Ics)7500ARated Voltage(V)230/400VRated Frequency(Hz)50/60HzCircumstance Temp.(°C)-5°C ~ +40°CElectrical Life≥8000Mechanical Life≥20000Type and tripping current scope of instantaneous releaseB 3In ~ 5In; C 5In ~ 10In; D 10In ~ 50InTerminal protectionIP20