Business Type:
Manufacturer/Factory,Trading Company
Business Range:
Ultraviolet Sterilizer, Water Descaling Equipment, Water Filter, Sand Filter, Water ..
Establishment:
2004
R&D Capacity:
OwnBrand, OEM
Terms of Payment:
LC, T/T, PayPal, WesternUnion
Main Markets:
North America, South America, Europe, Southeast Asia, Middle East, Africa, East Asia(Japan, South Korea), Australia, Domestic
OEM/ODM Service
Sample Available

Water Treatment Plant, Water Treatment, Water Softener manufacturer / supplier in China, offering 5000 Liter/Hour Automatic Water Softener with Duty / Standby, Contaminants and Chlorine Removed From Water by Activated Carbon Filter, Skid Installation 4000L/Hr Water Softener System Effectively Reduced Scale Build-up in Pipes and so on.

1
    YRS
General Supplier

China Agricultural Water Magnetic Water Treatment Equipment

Get Latest Price
Min. Order / Reference FOB Price
1 Pieces US $180.00/ Pieces
Local Area: Jian, Jiangxi, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal, WesternUnion
Material: Carbon Steel,Ss304,Ss316
Magent Power: 5000 Gauss,10000 Gauss,15000 Gauss
Working Pressure: 1.0MPa

Magnetic Water Descaling Equipment(Strong Water Mgnetizer)


I. Introduction
Strong magnetic water treatment equipment is treated with water with magnetic fields, to change the water physical structure on the premise of without changing the chemical composition of water, to achieve the purposes of anti-scaling, scale removal, sterilization, algae removal, anti-corrosion and anti-rust in water. There is strong magnetic field in central part of this products, but it generates little magnetic interference on outside, the effect of water processing is obvious, which is a new generation of novel structure and optimal product for water treatment.
II. Working principle
Making use of great energy that generates from neodymium, iron, boron, rare earth and permanent magnetic material, with optimal design, and form a crest vertical center field. When water or fluid flow through the vertical magnetic field, it will produce an electromotive force, the lattice refinement, the original water fouling crystal particle size from about 3.39 microns to about 0.22 microns, flow rate will be faster, the electromotive force generated is greater, the effect is more ideal, to achieve the purpose of anti-scaling and scale removal.
Meanwhile, water flow is treated by magnetic field, lead to the electrical conductivity and osmotic pressure changed and microbial cell ruptured, and cells stop breeding, which achieves effect of sterilization and algae removal.
Since the water treated by magnetic field, it will produce tiny electron flow, which change Fe2O3· NH2O into stable Fe3O4 and generates black magnetic iron oxide which deposited onto the tube wall surface to form a film barrier layer, the oxygen in the water separated from the pipe wall, in this case, it will realize the purpose of rust removal and prevention.


III.Product characteristics:

1. Clear and to prevent pipe scale and rust build
2. Environmental pollution does not use chemicals
3. Not energy, long lifespan for effective running.
4. No expert management of low maintenance costs
5. Small, simple and quick installation
6. Process to achieve zero emissions, save a lot of water
7. Improve the system heat transfer efficiency, energy saving (15% -30%)
8. Descaling process can produce hydrogen peroxide and reduce bacteria content in water


IV. Using scope
1. Central Air Conditioning System
2. Industrial cooling water system
3. Landscape, swimming pool system
4. Heat exchange system, heating system
5. Production and domestic hot water supply system

Magnetic water softener used in irrigation water

The magnetic water softener with 10000 to15000 Gauss magnet power is widely used in agricultural irrigation water.

The very strong and intense magnetic field within the water magnetier

(water magnets) causes the water molecules to change.

The magnetic field interferes with the ionic charges of the mineral ions (salts) in the water, which makes them not behave like the same salts any more.

This change results in the water acting "softer". The minerals contained in the water lose their ability to bond (bond ionically).

modelWater inlet-outletdimension(mm)flow rateMagnetic powerMaterialNet weightmminchdiameter*lengthm3/hour (Gauss)SSKgYLC-1251133x3304.93000-4000SS304/SS3163YLC-1.5401.5133x330123000-4000SS304/SS3163.5YLC-2502159x450194000-10000SS304/SS3165YLC-2.5652.5159x450284000-15000SS304/SS31611YLC-3803159x450504000-15000SS304/SS31615YLC-41004219x560804000-15000SS304/SS31618YLC-51255219x6001254000-15000SS304/SS31621YLC-61506273x7401804000-15000SS304/SS31630YLC-82008325x7903204000-15000SS304/SS31640YLC-1025010377x8504804000-15000SS304/SS31650YLC-1230012426x8006004000-15000SS304/SS31658YLC-1435014478x9507504000-15000SS304/SS31670YLC-1640016530x10008504000-15000SS304/SS31695YLC-1845018630x10509504000-15000SS304/SS316116YLC-2050020720x110011004000-15000SS304/SS316148

Calcium and magnesium no longer set like cement, and sodium (and other elements and salts) lose their ability to bind to the soil particles.