UV LED, LED Driver, UV Ballast manufacturer / supplier in China, offering Garle UV LED Power Supply, Garle G5200 Intelligent UV Variable Frequency Power Supplies for UV Printing, 6kw Electronic Ballast for UV Lamp in UV Curing and Disinfection Industry and so on.

1
    YRS
General Supplier
Supplier Homepage Auto, Motorcycle Parts & Accessories Car Light & Auto Mirror Headlight China UV Inverter Ballast Switching Power Supply Ultraviolet Light Ballast

China UV Inverter Ballast Switching Power Supply Ultraviolet Light Ballast

Get Latest Price
Min. Order / Reference FOB Price
1 Piece Contact Supplier
Local Area: Shenzhen, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: T/T
Usage: High Intensity Discharge, High Pressure Sodium, UV Lamp Dimming
Start Mode: Quick Start
Matched Tube: Mercury, Metal Halide Lamp, Gallium Lamp or Others
EPS dimmable intelligent UV inverter ballast 1kw to 35kw1.Key Features:
Power range: 1.0kW-15kW
Output voltage range:200V-500V
Receiving of fault switch signals from external equipment: when the external equipment fails, the UV viarable frequency power supply immediately sends alarms and stops.
Integrated inverter fan control to ensure appropriate exhaust and improve curing efficiency
Unique multi-stage speed setting, through the combination of the ON/OFF state of two external switches to create four levels of power values to be output
Functions of external terminal start and stop and external stand by to reduce energy consumption and prolong life
Various communication interfaces, including standard RS485 communication interface supporting Modbus RTU, and expansions for CANopen and Ethernet communication.2.Technical Features:
InputNominal voltage, frequency3 phase(4T#Series)380V 50/60HzVoltage allowable range3 phase(4T#series)300V~460VDigital input DIStandard configuration 3digital input DI1/DI2/DI3Analog input AIStandard:0~10Vvoltage input(AI)or0~20mAcurrent input(AI)
OutputOutput Voltage4T#Series:200-500VOutput frequency1.0KHzDigital output DO
Standard configuration 3digital output DO1/DO2/DO3Analog output AO2route0.0~10.0Vvoltage output signalRelay contact outputStandard configuration one groupAC 250V/2Anormally open/closed contactControl methodPower vector controlControl featurePower setting resolution0.1KWCurrent Restriction110%lamp rated currentVoltage Restriction110%lamp nominal voltagePower limitationMax output lamp rated powerOverload Capacity100%--Long termUnder voltage restrain in operationSpecially aim at low network voltage and frequent fluctuate network voltage users, even lower than allowable voltage range, system still maintain its longest conceivable running time by unique algorithm and residual distribution.RS485CommunicationStandard configurationRS485communication interface, it can control UV power supply running and stop, functional parameter setting and modifying, read equipment status, etc.Typical functionStandby functionSet standby power consumption to save energy when facility is interval.Working time recordRecord lamp working time when runningOperation functionExternal dry contact signal, RS485communication signal control facility start/stopDisplayOperation panel displayMonitor statusReal-time monitor output power, output current, output voltage, module temperature and setting power.Alarm contentLatest 6 times malfunction record, every malfunction cDetector ode, latest malfunction trip output power, setting power, output current, output voltage, DC voltage, module temperature, etc.Protect/alarm function3 phase current input loss phase, input under-voltage, input over-voltage, output over-current, output short circuit, facility overheat , temperature detection, output disconnection, internal storage damage, etc.EnvironmentAmbient temperature-10ºCto+45ºC(no freeze)Ambient humidity90%below(no frosting)SurroundingsIndoor(NO direct sunlight, corrosion, inflammable gas, oil fog, dust, etc.)AltitudeLower than1000mStructureProtection LevelIP20Cooling methodForced air cooling
3.Model Information:
Model
(G3000)Lamp power(KW)Input Voltage(V)Input Current(A)Output Voltage Range
(V)Max
Output
Current(A)Recommended
lamp voltage
(V)4T10033.0380V AC4.6200~500203004T10044.0380V AC6.1200~500203004T10055.0380V AC7.6200~500204004T10066.0380V AC9.3200~500204004T10088.0380V AC12.3200~500204504T101010.0380V AC15.1200~500354504T101212.0380V AC18.2200~500354504T101515.0380V AC22.8200~50035450
4.Control terminal function description
5.UV power supply control terminal function descriptionTerminal typeTerminal symbolTerminal functionNoteDigital outputDI1Programmable multifunctional
input terminal
Specific function /confirm/ied
By P2.01Connect CM valid
Threshold voltage<16VDI2DI3CMDI reference pointDI,24V common portAnalog inputAIVoltage/current signal input end
JP2 select voltage or current input0~10V voltage input
0~20mA current inputGNDAI,AO reference pointAI,AO common portAnalog outputAO1Programmable voltage output
end 1
Specific mapping variable determined by P2.15Voltage signal output 0~10V/1mAAO2Programmable voltage output
end 2
Specific mapping variable determined by P2.15DO outputDO1Programmable open collector output
Specific function determined by P2.06Max load current 150mA
Max withstand voltage 24VDO2DO3Power outputPOWProvide +24V/100mA powerAuxiliary power supplyCMDI,DO output reference pointDI,DO,24V common portExternal power source24VConnect 24V power supplyUse with DOExternal power source12VConnect 12Vpower supplyUse with GND,AI external potentiometer485 CommunicationRS-,RS+R485 communication interfaceConnect touch panel, PLCProgrammable outputTAnormalcy TA-TC break,TA-TB on, specific function determined by P2.06Contact capacity:AC 250V/2ATBTCAuxiliary interfaceRJ45Welding Equipment RJ45 interfaceConnect external operation panel
6.Basic functional parameter tableFunction typeFunction codeNameSetting rangeMinimum unitDefault setModify restrictionBasic function parameterP0.00Lamp rated power1.0KW~power supply rated power1Max powerP0.01Lamp rated voltage100V~500V1According to modelP0.02Operation channel selectionUnit:starting mode
0:operation panel control
1:external terminal control
2:serial communication control
Tens:Reserve
Hundreds:Reserve
Kilobit:Reserve10000★P0.03Power input channel/mode select1:External analog quantity AI(0~10V)
2:Serial communication(RS485/CAN/Ethernet)
3:Group preset
4:external terminal select(multifunctional terminal)
5:Jog dial digit setting11★P0.04Standby power setting5%~60%120P0.05Main monitor parameter selectd0.00~d0.091d0.01P0.06Auxiliary monitor parameter selectd0.00~d0.091d0.02P0.07Language0:Chinese
1:English10P0.08Communication settingUnits:Baud rate selection
0:2400bps 1:4800bps
2:9600bps 3:19200bps
4:38400bps 5:76800bps
Tens:Data format selection
0:1-8-1-N,RTU
1:1-8-1-O,RTU 2:1-8-1-E,RTU
3:1-8-2-N,RTU
Hundreds:Protocol selection
0:MODBUS protocol
1:Ethernet protocol
2:CAN communication protocol
3:GPRS protocol( support mobile-phone APP)
Kilobit:Reserve10002Basic function parametersP0.09Local address0~2011P0.10Local response time1~1000mS15P0.11Communication auxiliary functionUnit:Master-slave setup
0:Local is slave station
1:Local is master station Tens:Movement selection after communication failure
0:keep present status
1:Closing down
Hundreds:linkage control
0:Invalid
1:Valid
Kilobit:Reserve10000P0.12Communication timeout judgement3-100S15P0.13Power set compound mode0:Analog+Operation panel
1:Analog+Serial communication
2:Analog and serial communication choose large one
3:Analog and serial communication choose smaller one
4:Analog+External terminal selection11★P0.14Parameter initialization0:No movement
1:P0 group parameter reset to default
2:P1 group reset to default
3:P2 group reset to default
4:P0~P1 reset to default
5:P0~P2 reset to default
6:Clear error recording10★P0.15Parameter lockUnit:Parameter modify authority
0:All parameters are allowed to be modified
1:All parameters prohibit to be modified except for this parameter and lock password
Tens:password lock
0:Invalid
1:Valid----after preset the password,only input right password can be modified
Hundreds:Reserve
Kilobit:Reserve10000Basic functionP0.16Parameter lock code0~6553510P0.17Panel key function selectionUnit:Panel key locked
0: Not lock 1:All locked except for Jog dial, STOP and RUN
2:All locked except for STOP and RUN 3:All locked except for STOP
4:Locked all key
Tens:STOP key function
0:Invalid
1:Press STOP to close down at any control method
Hundreds:Reserve
Kilobit:Reserve10000★P0.18Parameters CopyUnit:Parameter upload and download
0:No movement
1:Parameter upload
2:Parameter download
Tens:Local download permission
0:Prohibit local download
1:Allow parameter download
Hundreds:Reserve
Kilobit:Reserve10000★P0.19LCD backlight time0~60 min12P0.20Shield power supply temperature test0:Shield invalid
1:Shield 1#Temperature test
2:Shield 2# Temperature test
3:Reserve10Basic operation parameterP1.00Vibrate control factor10~10001200★P1.01Reserve010P1.02Authority time setting0~6553510P1.03Proxy code1000~6553510P1.04Activate balance ratio2~10%12P1.05Lamp impedance setting10~10018P1.06Lamp activate current8.0~MAX115.0P1.07Lamp activate voltage10~30%130%P1.08Lamp activate time1~100S15P1.09Activate adjustment ratio10~40%120P1.10Function movement selectionUnit:Power supply fan start control
0:Power supply running fan start
1:power supply power on fan start
Tens:Mains input default phase detection
0:Invalid default phase detection
1:Valid default phase detection
Hundreds:Auto stabilivolt function
0:Invalid
1:Valid
Kilobit: activate pattern
0:Tunnel activateOther Manufacturing & Processing Machinery
1:Ladder activate10010P1.11Stabilivolt powerP0.04~100%1100P1.12Stabilivolt voltage100V~P0.011200Basic operation functionP1.13Stabilivolt upper limitP1.12~P0.011400P1.14Expansion function selectionUnit:Expansion card analog output function
0:Invalid
1:Valid
Tens:Expansion card digit input function
0:Invalid
1:Valid
Hundreds:Expansion card temperature control function
0:Invalid
1:Valid10000P1.15Holding current1~1015.0P1.16Ratio1~10001200P1.17Integral1~1000180P1.18Differential1~1000130P2.00ReserveAdvance operation parametersP2.01Digital input selectionUnit:Digital input terminal 1 function
Tens:Digital input terminal 2 function
Hundreds:Digital input terminal 3 function
0:Invalid control port
1:Multi-speed power control 1
2:Multi-speed power control 2
3:Start and stop control
4:External fault
5:Valid standby
6:Start permission
7:Fault resetting
Kilobit:Valid level choose anti-logic
0~7:3 bit binary system,bit=0 Valid connection,1 Valid disconnection10003★P2.02Multi-speed power setting 1[P0.04]~100%130%P2.03Multi-speed power setting 2[P0.04]~100%150%P2.04Multi-speed power setting 3[P0.04]~100%180%P2.05Multi-speed power setting 4[P0.04]~100%1100%P2.06Digital output selectionUnit:Relay output (TA/TB/TC)
Tens:Output port 1(DO1)
Hundreds:Output port2(DO2)
Kilobit:Output port3(DO3)
0:Control port in idle
1:Lamp air draft signal
2:Malfunction signal
3:Start complete
4:Power supply in service
5:Standby in service
6:Voltage signal 1
7:Voltage signal 2
8:Output power upper limit
9:Output power lower limit
10:Intelligent air draft signal10002P2.07Voltage set value 1100V~MAX1150VAdvanced operation parametersP2.08Voltage set value 2100V~MAX1150VP2.09Output power upper limitP2.10~100%150%P2.10Output power lower limitP0.04~P2.09140%Advanced operation parametersP2.11Lamp ventilation latency start0~60min11P2.12Lamp ventilation latency close0~60min11P2.13VC1 input upper limit voltageP2.14~10.0V0.110.0P2.14VC1 input lower limit voltage0.0V~P2.130.10.0P2.15Analog output selectionUnit:AO1 output selection
0:output port in idle
1:output power
2:output voltage
3:output current
4:Intelligent ventilation
Tens:AO2 output selection
0:output port in idle
1:output power
2:output voltage
3:output current
4:Intelligent ventilation
Hundreds:Reserve
Kilobit:Reserve10000P2.16Analog output AO1 upper limit0~10.0V0.110.0P2.17Analog output AO2 upper limit0~10.0V0.110.0P2.18Intelligent ventilation delay0~60min12P2.19Intelligent ventilation set point 1P2.20~100%178%P2.20Intelligent ventilation set point 210%~P2.19168%7. Monitor parameter tableMonitor codeContentUnitAddressD0.00Lamp powerKW0xD000D0.01Lamp currentA0xD001D0.02Lamp voltageV0xD002D0.03Lamp impedanceΩ0xD003D0.04Given powerKW0xD004D0.05DC voltage
V0xD005D0.06Equipment temperature detection 1#ºC0xD006D0.07Equipment temperature detection 2#ºC0xD007D0.08Transformer temperatureºC0xD008D0.09Program version0xD009D0.10Latest malfunction record0xD010D0.11History malfunction record 10xD011D0.12History malfunction record 20xD012D0.13History malfunction record 30xD013D0.14History malfunction record 40xD014D0.15History malfunction record 50xD015D0.16History malfunction record 60xD016D0.17Latest malfunction output powerKW0xD017D0.18Latest malfunction output currentA0xD018D0.19Latest malfunction output voltageV0xD019D0.20Latest malfunction lamp impedanceΩ0xD020D0.21Latest malfunction DC voltageV0xD021D0.22Latest malfunction equipment temperature 1#ºC0xD022D0.23Latest malfunction equipment temperature2#ºC0xD023D0.24Latest malfunction transformer temperatureºC0xD024D1.00BUS information quantity0xD100D1.01BUS receive error data quantity0xD101D1.02BUS CRC verify error quantity0xD102D1.03Encryption operation timeH0xD103D1.04Power supply operation timeH0xD104D1.05Reference password0xD105D1.06Input terminal status0xD106D1.07Output terminal status0xD107D1.08Analog input AI0xD108D1.09Analog output AO1V0xD109D1.10Analog output AO2V0xD110