Business Type:
Manufacturer/Factory
Business Range:
UV Power Supply, Electronic Ballast, Electronic Power Supply, UV Ballast, UV Variable ..
Establishment:
2012
R&D Capacity:
OwnBrand, ODM, OEM
Terms of Payment:
T/T
Main Markets:
North America, South America, Europe, Southeast Asia, Middle East, East Asia(Japan, South Korea), Domestic
OEM/ODM Service
Sample Available

UV LED, LED Driver, UV Ballast manufacturer / supplier in China, offering Garle UV LED Power Supply, Garle G5200 Intelligent UV Variable Frequency Power Supplies for UV Printing, 6kw Electronic Ballast for UV Lamp in UV Curing and Disinfection Industry and so on.

1
    YRS
General Supplier
Supplier Homepage Lights & Lighting Lighting Fixtures Ballast China UV Lamp Ballast HID Electronic Ballast Ultraviolet Light Ballast

China UV Lamp Ballast HID Electronic Ballast Ultraviolet Light Ballast

Get Latest Price
Min. Order / Reference FOB Price
1 Piece Contact Supplier
Local Area: Shenzhen, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: T/T
Usage: High Intensity Discharge, High Pressure Sodium, UV Lamp Dimming
Start Mode: Quick Start
Matched Tube: Mercury, Metal Halide Lamp, Gallium Lamp or Others
Compact Full Digital UV Lamp Ballast 3000W 440VAC High EfficiencyKey Features:
1. Wide voltage input/output, fit for various UV lamp
1.1. Build-in BUCK voltage stabilizing circuit, can be running on AC300-460V;
1.2. Flexible setting output voltage from 200V-500V.
2. Excellent energy saving effect
2.1. Save 30%-50% power consumption comparing with traditionaPower Transmission Parts l transformer;
2.2. Work efficiency reach to 98%.
3. Stable output energy, continuous adjustable
3.1. Control system controlled by power vector control algorithm to guarantee output power constant adjustable;
3.2. Output energy keeps constant when voltage and environment temperature fluctuate.
4. User-friendly
4.1. Intelligent start, auto-detective lamp status, auto-compensation energy descentCrushing & Culling Machine problem caused by air draft;
4.2. 0~10V voltage continuous control power output;
4.3. Unique standby mode to reduce power consumPower Supply & Distribution ption and prolong lamp lifetime;
4.4. Visual display output current, voltage and power. Major loop and control loop wiring terminal are pluggable which convenient for wiring.
5. Abundant protection function
5.1 Nearly 20 kinds protection function, provide more comprehensive protection on the premise of equipment running normally;
5.2 Receive(PT100,NTC)temperature detective analog quantity signal, real-time monitor lamp temperature and achieve over-temperature protection;
5.3 Receive external equipment malfunction switching value signal, UV power supply immediately alarm to close down the equipment when external equipment break down.
6. Integrated frequency conversion draught fan control function
Switch to analog quantity output by SVPWM control algorithm, control draught fan's blast capacity by control frequency converter's output frequency timely to keep lamp voltage and temperature constant to achieve speedy curing effect.
On standby mode by using unique control algorithm to keep lamp voltage fluctuate in a certain range , lamp response time is 200mS from standby to full power output to achieve speedy response curing requirement.
7. Unique multiple speed power given
By 2 external switching value ON/OFF combination, switch 4 level adjustable power's preset to achieve different power output switch function. Completely replace traditional transformer+capacitor drive mode.
8. Abundant communication interface
Support Modbus, CANopen and Ethernet, etc. communication protocol to achieve networking function between multiple power supply , power supply and other industrial control equipment.
Technical Features:
InputNominal voltage, frequency3 phase(4T#Series)380V 50/60HzVoltage allowable range3 phase(4T#series)300V~460VDigital input DIStandard configuration 3digital input DI1/DI2/DI3Analog input AIStandard:0~10Vvoltage input(AI)or0~20mAcurrent input(AI)
OutputOutput Voltage4T#Series:200-500VOutput frequency1.0KHzDigital output DO
Standard configuration 3digital output DO1/DO2/DO3Analog output AO2route0.0~10.0Vvoltage output signalRelay contact outputStandard configuration one groupAC 250V/2Anormally open/closed contactControl methodPower vector controlControl featurePower setting resolution0.1KWCurrent Restriction110%lamp rated currentVoltage Restriction110%lamp nominal voltagePower limitationMax output lamp rated powerOverload Capacity100%--Long termUnder voltage restrain in operationEspecially aim at low network voltageLean Pipe & Pipe Rack System and frequently fluctuate network voltage users, even lower than allowable voltage range, system still maintains its longest conceivable running time by unique algorithm and residual distribution.RS485CommunicationStandard configurationRS485communication interface, it can control UV power supply running and stop, functional parameter setting and modifying, read equipment status, etc.Typical functionStandby functionSet standby power consumption to save energy when the facility is interval.Working time recordRecord lamp working time when runningOperation functionExternal dry contact signal, RS485communication signal control facility start/stopDisplayOperation panel displayBoiler & Furnace Monitor statusReal-time monitor output power, output current, output voltage, module temperature and setting power.Alarm contentLatest 6 times malfunction record, every malfunction code, latest malfunction trip output power, setting power, output current, output voltage, DC voltage, module temperature, etc.Protect/alarm function3 phase current input loss phase, input under-voltage, input over-voltage, output over-current, output short circuit, facility overheat , temperature detection, output disconnection, internal storage damage, etc.EnvironmentAmbient temperature-10ºCto+45ºC(no freeze)Ambient humidity90%below(no frosting)SurroundingsIndoor(NO direct sunlight, corrosion, inflammable gas, oil fog, dust, etc.)AltitudeLower than1000mStructureProtection LevelIP20Cooling methodForced air cooling
Model Information:
Model
(G3000)Lamp power(KW)Input Voltage(V)Input Current(A)Output Voltage Range
(V)Max
Output
Current(A)Recommended
lamp voltage
(V)4T10033.0380V AC4.6200~500203004T10044.0380V AC6.1200~500203004T10055.0380V AC7.6200~500204004T10066.0380V AC9.3200~500204004T10088.0380V AC12.3200~500204504T101010.0380V AC15.1200~500354504T101212.0380V AC18.2200~500354504T101515.0380V AC22.8200~50035450
Product Detail
G3000 Series UV power supply exterior and installation hole site:Model (G3000)Install hole site mmExterior size
mmAperture mmScrewMounting wayABHWD4T1003110497520160150Φ10M8Wall-mounted4T10044T10054T10064T10084T1010110497520180178Φ10M8Wall-mounted4T10124T1015UV power supply control loop wiring diagram: