Business Type:
Manufacturer/Factory
Business Range:
UV Power Supply, Electronic Ballast, Electronic Power Supply, UV Ballast, UV Variable ..
Establishment:
2012
R&D Capacity:
OwnBrand, ODM, OEM
Terms of Payment:
T/T
Main Markets:
North America, South America, Europe, Southeast Asia, Middle East, East Asia(Japan, South Korea), Domestic
OEM/ODM Service
Sample Available

UV LED, LED Driver, UV Ballast manufacturer / supplier in China, offering Garle UV LED Power Supply, Garle G5200 Intelligent UV Variable Frequency Power Supplies for UV Printing, 6kw Electronic Ballast for UV Lamp in UV Curing and Disinfection Industry and so on.

1
    YRS
General Supplier
Supplier Homepage Lights & Lighting Lighting Fixtures Ballast China UV Lamp Ballast HID Electronic Ballast Ultraviolet Light Ballast

China UV Lamp Ballast HID Electronic Ballast Ultraviolet Light Ballast

Get Latest Price
Min. Order / Reference FOB Price
1 Piece Contact Supplier
Local Area: Shenzhen, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: T/T
Usage: High Intensity Discharge, High Pressure Sodium, UV Lamp Dimming
Start Mode: Quick Start
Matched Tube: Mercury, Metal Halide Lamp, Gallium Lamp or Others
220V 3000 Watt UV Lamp Ballast Dimmable Low Power ConsumptionKey Features:
1. Wide voltage input/output, fit for vDetector arious UV lamp
1.1. Build-in BUCK voltage stabilizing circuit can be running on AC300-460V;
1.2. The flexible setting output voltage from 200V-500V.
2. Excellent energy saving effect
2.1. Save 30%-50% power consumption comparing with traditional transformer;
2.2. Work efficiency reaches to 98%.
3. Stable output energy, continuous adjustable
3.1. Control system controlled by power vector control algorithm to guarantee output power constantly adjustable;
3.2. Output energy keeps constant when voltage and environment temperature fluctuate.
4. User-friendly
4.1. Intelligent start, auto-detective lamp status, auto-compensation energy descent problem caused by air draft;
4.2. 0~10V voltage continuous control power output;
4.3. Unique standby mode to reduce power consumption and prolong lamp lifetime;
4.4. Visual display output current, voltage, and power. Major loop and control loop wiring terminal are pluggable which convenient for wiring.
5. Abundant protection function
5.1 Nearly 20 kinds of protection function, provide more comprehensive protection on the premise of equipment running normally;
5.2 Receive(PT100, NTC)temperature detective analog quantity signal, real-time monitor lamp temperature and achieve over-temperature protection;
5.3 Receive external equipment malfunction switching value signal, UV power supply immediately alarm to close down the equipment when external equipment breaks down.
6. Integrated frequency conversion draught fan control function
Switch to analog quantity output by SVPWM control algorithm, control draught fan's blast capacity by control frequency converter's output frequency timely to keep lamp voltage and temperature constant to achieve speedy curing effect.
On standby mode by using a unique control algorithm to keep lamp voltage fluctuate in a certain range, lamp response time is 200mS from standby to full power output to achieve speedy response curing requirement.
7. Unique multiple speed power is given by 2 external switching value ON/OFF combination, switch 4 levels adjustable power's preset to achieve different power output switch function. Completely replace traditional transformer+capacitor drive mode.
8. Abundant communication interface
Support Modbus, CANopen, and Ethernet, etc. communication protocol to achieve networking function between multiple power supply, power supply, and other industrial control equipment.
Technical Features:
InputNominal voltage, frequency3 phase(4T#Series)380V 50/60HzVoltage allowable range3 phase(4T#series)300V~460VDigital input DIStandard configuration 3digital input DI1/DI2/DI3Analog input AIStandard:0~10Vvoltage input(AI)or0~20mAcurrent input(AI)
OutputOutput Voltage4T#Series:200-500VOutput frequency1.Ventilation Equipment 0KHzDigital output DO
Standard configuration 3digital output DO1/DO2/DO3Analog output AO2route0.0~10.0Vvoltage output signalRelay contact outputStandard configuration one groupAC 250V/2Anormally open/closed contactControl methodPower vector controlControl featurePower setting resolution0.1KWCurrent Restriction110%lamp rated currentVoltage Restriction110%lamp nominal voltagePower limitationMax output lamp rated powerOverload Capacity100%--Long termUnder voltage restrain in operationEspecially aim at low network voltage and frequently fluctuate network voltage users, even lower than allowable voltage range, system still maintains its longest conceivable running time by unique algorithm and residual distribution.RS485CommunicationStandard configurationRS485communication interface, it can control UV power supply running and stop, functional parameter setting and modifying, read equipment status, etc.Typical functionStandby functionSet standby power consumption to save energy when the facility is interval.Working time recordRecord lamp working time when runningOperation functionExternal dry contact signal, RS485communication signal control facility start/stopDisplayOperation panel displayMonitor statusReal-time monitor output power, output current, output voltage, module temperature and setting power.Alarm contentLatest 6 times malfunction record, every malfunction code, latest malfunction trip output power, setting power, output current, output voltage, DC voltage, module temperature, etc.Protect/alarm function3 phase current input loss phase, input under-voltage, input over-voltage, output over-current, output short circuit, facility overheat , temperature detection, output disconnection, internal storage damage, etc.EnvironmentAmbient temperature-10ºCto+45ºC(no freeze)Ambient humidity90%below(no frosting)SurroundingsIndoor(NO direct sunlight, corrosion, inflammable gas, oil fog, dust, etc.)AltitudeLower than1000mStructureProtection LevelIP20Cooling methodForced air cooling
Model Information:
Model
(G3000)Lamp power(KW)Input Voltage(V)Input Current(A)Output Voltage Range
(V)Max
Output
Current(A)Recommended
lamp voltage
(V)4T10033.0380V AC4.6200~500203004T10044.0380V AC6.1200~500203004T10055.0380V AC7.6200~500204004T10066.0380V AC9.3200~500204004T10088.0380V AC12.3200~500204504T101010.0380V AC15.1200~500354504T101212.0380V AC18.2200~500354504T101515.0380V AC22.8200~50035450
Product Detail
G3000 Series UV power supply exterior and installation hole site:Model (G3000)Install hole site mmExterior size
mmAperture mmScrewMounting wayABHWD4T1003110497520160150Φ10M8Wall-mounted4T10044T10054T10064T10084T1010110497520180178Φ10M8Wall-mounted4T10124T1015UV power supply control loop wiring diagram:
Terminal typeTerminal symbolTerminal functionNoteDigital outputDI1Programmable multifunctional
input terminal
Specific function /confirm/ied
By P2.01Connect CM valid
Threshold voltage<16VDI2DI3CMDI reference pointDI,24V common portAnalog inputAIVoltage/current signal input end
JP2 select voltage or current input0~10V voltage input
0~20mA current inputGNDAI,AO reference pointAI,AO common portAnalog outputAO1Programmable voltage output
end 1
Specific mapping variable determined by P2.15Voltage signal output 0~10V/1mAAO2Programmable voltage output
end 2
Specific mapping variable determined by P2.15DO outputDO1Programmable open collector output
Specific function determined by P2.06Max load current 150mA
Max withstand voltage 24VDO2DO3Power outputPOWProvide +24V/100mA powerAuxiliary power supplyCMDI,DO output reference pointDI,DO,24V common portExternal power source24VConnect 24V power supplyUse with DOExternal power source12VConnect 12Vpower supplyUse with GND,AI external potentiometer485 CommunicationRS-,RS+R485 communication interfaceConnect touch panel, PLCProgrammable outputTAnormalcy TA-TC break,TA-TB on, specific function determined by P2.06Contact capacity:AC 250V/2ATBTCAuxiliary interfaceRJ45RJ45 interfaceConnect external operation panelOperation function description:ItemsFunction DescriptionDisplay functionFirst lineOperation panel working mode, display monitor parameter, status parameter and parameter setting2nd lineFunction code, status parameter and monitor parameter 13rd lineParameter function explanation and monitor parameter 2base linePower supply working mode and malfunction alarm codeKeyboard functionESCReturn key. In normal monitor mode press that key to enter into query model of status parameter, monitor parameter and operation status parameter. In other mode press that key to return to previous level.SETSetting key. Confirm present status or parameter(parameter is stored in internal storage) and enter in next level function menu.UPData modify increase key to modify function code or status parameter.DOWNData modify decrease key to modify function code or status parameter.>>Right shift key. In any status which modified by UP and DOWN key press this key to select modifying data bit, modifying position wElectrical Control System ill be flickering.Speaker,Trumpet & Buzzer <<Left shift key. In any status which modified by UP and DOWN key press this key to select modifying data bit, modifying position will be flickering.