Business Type:
Manufacturer/Factory,Trading Company
Business Range:
Ultraviolet Sterilizer, Water Descaling Equipment, Water Filter, Sand Filter, Water ..
Establishment:
2004
R&D Capacity:
OwnBrand, OEM
Terms of Payment:
LC, T/T, PayPal, WesternUnion
Main Markets:
North America, South America, Europe, Southeast Asia, Middle East, Africa, East Asia(Japan, South Korea), Australia, Domestic
OEM/ODM Service
Sample Available

Water Treatment Plant, Water Treatment, Water Softener manufacturer / supplier in China, offering 5000 Liter/Hour Automatic Water Softener with Duty / Standby, Contaminants and Chlorine Removed From Water by Activated Carbon Filter, Skid Installation 4000L/Hr Water Softener System Effectively Reduced Scale Build-up in Pipes and so on.

1
    YRS
General Supplier

China Zero Pollution Magnetic Water Treatment Device

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $380.00/ Piece
Local Area: Jian, Jiangxi, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal, WesternUnion
Type: Magnetic Power
Usage: Environmental Protection, Chemical Industry, Water Treatment
Motive Force: Pressure


MAGNETIC WATER TREATMENT COMPARATIVE CHART

S.NoMAGNETIC WATER TREATMENTCHEMICAL baseD SOFTENER1.No Salt required - Time & Cost savingSalt to be added often2.Is attached as a part of the pipelineRequires extra plumbing & Space3.Works without operatorNeed operator every time4.Good for human consumptionPresence of Sodium sited, so not good for consumption5.Zero maintenance unitsRegular maintenance & Services required.6.Magnets have a life of about 20-25 years.Resin needs replacement years after 3 years7.Continuous flow without chokingFrequently choking8.Useful for generators in scale removalDoes not remove existing scale9.Generate zero pollutionWater pollution is caused due to out flow of the salt.10.Removes existing scales (Calcium & Magnesium).Does not remove existing Scales11.Output of product remain constantOut put varies due to operational factors12.Also helps in removing parts of SulphurDoes not remove sulphur & Iron and Iron

Technology
In this FTA uses a magnetic or electrostatic field to alter the reaction between scale-forming ions in hard water. Hard water contains high levels of calcium, magnesium, and other divalent cations. When subjected to heating, the divalent ions form insoluble compounds with anions such as carbonate. These insoluble compounds have a much lower heat transfer capability than heat transfer surfaces such as metal. They are insulators. Thus additional fuel consumption would be required to transfer an equivalent amount of energy.
However, the availability of high-power, rare-earth element magnets has advanced the magnetic technology to the point where it is more reliable. Similar advances in materials science, such as the availability of ceramic electrodes and other durable dielectric materials, have allowed the electrostatic technology to also become more reliable.
The general operating principle for the magnetic technology is a result of the physics of interaction between a magnetic field and a moving electric charge, in this case in the form of an ion. When ions pass through the magnetic field, a force is exerted on each ion. The forces on ions of opposite charges are in opposite directions. The redirection of the particles tends to increase the frequency with which ions of opposite charge collide and combine to form a mineral precipitate, or insoluble compound. Since this reaction takes place in a low-temperature region of a heat exchange system, the scale formed is non- adherent. At the prevailing temperature conditions, this form is preferred over the adherent form, which attaches to heat exchange surfaces.
The operating principles for the electrostatic units are much different. Instead of causing the dissolved ions to come together and form non-adherent scale, a surface charge is imposed on the ions so that they repel instead of attract each other. Thus the two ions (positive and negative, or cations and anions, respectively) of a kind needed to form scale are never able to come close enough together to initiate the scale-forming reaction. The end result for a user is the same with either technology; scale formation on heat exchange surfaces is greatly reduced or eliminated.
To customers details:
01.What is the capacity(m3/hour)you required for this equipment?
or you could confirm diameter of the water pipe.
02.What is the material for this descaling equipment?
Ordinary carbon steel is Okay? stainless steel(SS304/SS316)?
Which means,what is the source of raw water to be treated?
03.What is the magnet power for it?
ordinary 5000 gauss?higher 10000 gauss?
Magnetic Water descaler Technical parameters:


model inlet and outletdimension(mm)flow rateVertical centerWorking mediumweightmminchdiameter*lengthm 3 /hstrong magnetism (mt)temperature
( . C)KgYLC-1251108x3304.91600-803YLC-1.5401.5108x330121600-803.5YLC-2502159x450191600-805YLC-2.5652.5159x450281600-8011YLC-3803159x450501600-8015YLC-41004219x560801600-8018YLC-51255219x6001251600-8021YLC-61506273x7401801600-8030YLC-82008325x7903201600-8040YLC-1025010377x8504801600-8050YLC-1230012426x8006001600-8058YLC-1435014478x9507501600-8070YLC-1640016530x10008501600-8095YLC-1845018630x10509501600-80116YLC-2050020720x110011001600-80148


Advandge:
Our services:We provide 24 hours online customer service.
Any inquiry about water treatment system, please feel free to contact me for further details!
Contact information:
Mobile phone: +86 13585066069
Website: http://yldwater.en.made-in-china.com
Official website: www.zgyld.com
Guarantee period:1 year
After-sale service:800-827-87-226