Measureresidual chlorine, HOCL, pH, and temperatureat the same time. Can be widely used in power, water plants, hospitals and other industries in avariety of water quality and continuous monitoring of residual chlorine and pH.Technical indicators
1. Display mode: LCD display,Englishmenu operation;
2. Measurement range:
residual chlorine: 0~20.00mg/L, resolution: 0.01mg/L;
HOCL: 0~10.00mg/L, resolution: 0.01mg/L;
pH value: 0~14.00pH, resolution :0.01pH;
Temperature: 0~99.9°C, Resolution: 0.1°C;
3, Accuracy:
residual chlorine: ±2% or ±0.035mg/L,depends on which one bigger;
HOCL: ±2% or ±0.035 mg/Ldepends on which one bigger;
pH: ±0.05pH; Temperature: ±0.5°C (0~60.0°C);
4, sample temperature: 0~ 60.0 °C, 0.6MPa;
5, sample flow rate: 200 to 250 mL/min automatically adjustable
6, the minimum detection limit: 0.01mg/L
7, electronic unit repeatability error: residual chlorine: ±0.02mg /L, pH value: ±0.02pH;
8, stability: residual chlorine: ±0.02 (mg /L) /24h, pH value: ±0.02pH/24h;
9, pH input impedance: ≥1012 Ω;
10, clock accuracy: ±1 minute /month;
11,Currentisolated output: 0~ 10mA (load <1.5kΩ), 4~ 20mA (load <750 Ω);
12, the output current error: ≤± 1% FS;
13. Data storage quantity: 1month (1point/5 minutes);
14, high and low alarm relay: AC220V,7A; Hysteresisvaluefrom0 to 5.00mg/L is arbitrarily adjustable.
15, RS485 communication interface (optional);
16, power supply: AC220V ±22V, 50Hz ±1Hz; optional DC24V power supply.Default isAC220V.
17, protection class: IP65;
18, external dimensions: 146 (long) x146 (width) x108 (deep) mm, open holesize: 138 x138 mm; Note:also supportwall mounted, please specify when ordering.
19, power: ≤10W;
20, weight: The second table: 0.8kg,weight offlow cell with chlorine, pH electrodeis2.5kg;
21, working conditions: ambient temperature 0~ 60 °C,relative humidity <85%;
22, using flow-through installation,waterinlet and outlet diameterisΦ10.
Note:
-Two currentoutputs are available. One residual chlorine corresponds to current output, and the other selects pH or temperature corresponding current output. The factory standard configurationisresidual chlorine corresponding current output. Please specify when ordering.
-Standard configuration:oneYL5601 secondarymeter,one5601-1 online residual chlorine electrode,one5601-2 online pH electrode,oneflow cell.
Main featureLCD display,Englishmenu type,English record.Prefabricated long-life membranes are easy to replace.Waterproof and dustproof design: Protection class IP65, suitable for outdoor use.Electromagnetic Compatibility (EMC/RFI) Design: Designed and manufactured according to the European standard EN50081/50082.Alarm function: alarm signal isolated output, alarm upper and lower limit can be arbitrarily set, the alarm lagswithdrawn.Network function: Isolated current output and RS485 communication interface.Historical curve: continuously record data for one month, one point for five minutes.Notepad function: records 200 messages.Manual current source: facilitates recording and testing devices.Built-in real-time clock: Provides time reference for various functions.Industrial Control Watchdog: Make sure the meter does not crash.Password management: Parameter settings and maintenance are password protected.
Contact person: Tu
Tel: +86-18985135245