Business Type:
Manufacturer/Factory
Business Range:
Current Transformer, Voltage Transformer, Vacuum Circuit Breaker, Sf6 Load Switches
Establishment:
1996
R&D Capacity:
OwnBrand, ODM, OEM
OEM/ODM Service
Sample Available

Transformer, Dry Transformer, Distribution Transformer manufacturer / supplier in China, offering 12kv Dry Type Power Transformer (SC9), (AZZBJ16-35W) Outdoor Epoxy Cast-Resin 1000A 0.2s/0.5 30/50va Current Transformer, (LJW(D)1-35) Outdoor (indoor) Oil-Immersed Current Transformer and so on.

1
    YRS
General Supplier
Supplier Homepage Electrical & Electronics Power Transmission & Transformer Transformer (SC(B)-10) 12kv Resin Insulation Dry-Type Power Transformer

(SC(B)-10) 12kv Resin Insulation Dry-Type Power Transformer

Get Latest Price
Min. Order / Reference FOB Price
1 Piece Contact Supplier
Local Area: Wenzhou, Zhejiang, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Brand: Talent
Application: Power
Phase: Three
Core: Core-type Transformer
SC(B)-10 Dry-type Power Transformer
Normal operation condition
Altitude< 1000 m Indoor
Max. Ambinet temperature +40ºC
Max. Daily average temperature+ 30ºC
Max. annual average temperature +20ºC
Min. temperature -5ºC
Supply transformers operate under special conditions according to customer requirements.
Features
1. The core is made of cold rolled grained high-oriented silicon steel sheets that thickness≤0.3mm with 45 degree mitred joints. The surface is coated with special resin for moisture and rust proof.
2. Normally the LV winding materials is copper foil cylinder type excepet for small capacity transformers which LV winding materials is copper wire; The HV winding structure is multi-layer cylinder type that has good ampere-turn balance, low leakage flux, high mechanical strength and strong short-circuit withstand capability.
3. By installing the low noise fans that controled by the temperature control device,the operation capacity of the transformer can be increased by 40%.
4. The temperature device which sensers buried in LV winding can control the fans or send alarm & trip signals to protect the transformer.
5. The transformer can be installed in a enclosure which protetion class is IP20 or IP23, the enclosure can prevent small animals coming inside the transformer to avoid short circuit, and also safeguard the personal safety.
6. Sc(b)9No-load losses Equal To Standard Value In GB/T10228-2008
No-load losses Equal To Tagged Value In GB/T10228-2008
Sc(b)10 No-load losses Decrease By 10% Compared with Standard Value In GB/T10228-2008
No-load losses Decrease By 5% Compared with Tagged Value In GB/T10228-2008
Technical Data
6KV 10KV main 30kVA~2500KVA NLTC distribution transformerNominal
capacity(KVA)Voltage unitcombinationLow voltage(KV)Vector GroupNo-load loss(W)Loasloss (W)No-load current(%)Short-circuit impedance(%)High voltage(KV)High voltage tap
range
F class
(120ºC)H class
(120ºC)30
6
6.3
6.6
10
10.5
11
±2x2.5% or±5%
0.4
Yyn0
or
Dyn111907107602.04.050270100010702.080370138014801.5100400157016901.5125470185019801.3160540213022801.3200620253027101.1250720276029601.1315880347037301.0400980399042801.05001160488052301.06301340588062900.856301300596064000.856.08001520696074600.8510001770813087600.85125020909690103000.851600245011700125000.852000305014400155000.702500360017100184000.701600245012900139000.858.02000305015900171000.702500360018800202000.70
6KV 10KV main 315kVA~2500KVA NLTC Power transformerNominal
capacity(KVA)Voltage unitcombinationLow voltage(KV)Vector GroupNo-load loss(W)Loasloss (W)No-load current(%)Short-circuit impedance(%)High voltage(KV)High voltage tap
range
F class
(120ºC)H class
(120ºC)630
6
6.3
6.6
10
10.5
11
±2x2.5% or±5%
3
3.15
6
6.3
Yyn0
or
Dyn111440636068001.0
4.08001620760081301.010001940878093900.851250234010400111000.851600279012700136000.852000360015200162000.702500423017800191000.703150504020900223000.60400010
10.5
11603025100269000.606.05000720029700318000.506300850035300378000.50
6KV 10KV main 630kVA~6300KVA OLTC distribution transformerNominal
capacity(KVA)Voltage unitcombinationLow voltage(KV)Vector GroupNo-load loss(W)Loasloss (W)No-load current(%)Short-circuit impedance(%)High voltage(KV)High voltage tap
range
F class
(120ºC)H class
(120ºC)315
6
6.3
6.6
10
10.5
11
±4x2.5%0.4
Yyn0
Dyn11
990361038601.14.04001120427045701.15001290522055801.16301490617066001.06301440636068001.06.08001710750080201.010001980878093900.851250234010400111000.851600272012400133000.852000342015200162000.702500396018100194000.70Note: The physical dimension in the manual is only provided for design reference, and the fimal dimension shall be based on the actual outline drawing.