Sf6 Integration Tester, Sf6 Comprehensive Tester, Sf6 Decomposition Tester manufacturer / supplier in China, offering Sf6 Dew Point Tester, CT/PT Tester, CT/PT Analyzer and so on.

1
    YRS
General Supplier
Supplier Homepage Instruments & Meters Electronic Instrument Frequency Meter 0.1Hz Very Low Frequency High Voltage Tester 40kv

0.1Hz Very Low Frequency High Voltage Tester 40kv

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $3.00/ Piece
Local Area: Sanya, Hainan, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Frequency Range: 0.1Hz, 0.05Hz, 0.02Hz
Display: Digital
Type: Cable Testing
The VLF testers (Generator) are suitable for
Testing cables, transformers, switchgear,
Rotating machinery, and other
Electrical apparatus.VLF Advantages:
1. Easiest to use Fully automatic microcontroller
2. Built-in printer
3. True sine wave output
4. Real-time display of actual output waveform
5. Ergonomic, menu guided, large backlit LCD
6. Storage of test results for later retrieval and print.
7. Over voltage and current protected
8. Variable frequency 0.1Hz, 0.05Hz, 0.02 Hz
9. Data of current, voltage and waveform directly sampled at HV side.
10. AC testing does not degrade good cable insulation
11. Harmful space charges are not injected into the cable insulation
12. No traveling waves are generated during testing
13. Rugged and reliable design less prone to failure from transientsSafety Features
1. Short circuit protected.
2. Status display of all important safety functions and messages.
3. Safe, easy to use operation with emergency off and key switch lock-out.
4. Fully integrated discharge circuit to safely ground the DUT after testing.
5. Zero start interlock.
6. Zero voltage switching.
Specifications
1. Input: 220 ± 10% Volts AC, 50/60 Hz, single phase.
2. Output-Voltage: 40KV.
3. Output frequency: 0.1Hz, 0.05Hz, 0.02Hz.
4. Stability of frequency: Fluctuation < 0.5%
5. Measurement accuracy: ± 3%.
6. Positive and negative voltage peak errors: ≤ 3%.
7. Voltage waveform distortion: ≤ 5%
8. Construction: In two units: Controller and Booster...
9. Ambient conditions of use: Temperature Indoor and outdoor: -10 to + 50ºC
10. Humidity: ≤ 85%
ModelOutput
Voltage/Current
(Peak)LoadCapacityControlUnitBoosterFuseFrequency/CapacitanceNetDim.
(cm)NetWt
(kg)NetDim.
(cm)NetWt
(kg)VLF-30/1.130KV/29mA0.1Hz≤1.1uF
0.05Hz≤2.2uF
0.02Hz≤5.5uF28x37x22533x18x34258AVLF-40/1.140KV/29mA0.1Hz≤1.1uF
0.05Hz≤2.2uF
0.02Hz≤5.5uF28x37x22535x20x36458AVLF-50/1.150KV/59mA0.1Hz≤1.1uF
0.05Hz≤2.2uF
0.02Hz≤5.5uF28x37x22537x24x394510AVLF-60/0.560KV/59mA0.1Hz≤0.5uF
0.05Hz≤1.0uF
0.02Hz≤2.5uF28x37x22533x18x34
33x18x3425+4520AVLF-70/0.570KV/59mA0.1Hz,≤0.5µF
0.05Hz,≤1.0µF
0.02Hz,≤2.5µF28x37x22533x18x34
35x20x3625+4520AVLF-80/0.580KV/59mA0.1Hz,≤0.5µF
0.05Hz,≤1.0µF
0.02Hz,≤2.5µF28x37x22533x18x34
37x24x3925+4520AVLF-90/0.590KV/59mA0.1Hz,≤0.5µF
0.05Hz,≤1.0µF
0.02Hz,≤2.5µF28x37x22533x20x35
37x24x3930+4520A