Business Type:
Manufacturer/Factory
Establishment:
2012
R&D Capacity:
ODM, OEM, Other
OEM/ODM Service
Sample Available

Current Transformer, 0.333V Split Current Sensor, 5A Split Core CT manufacturer / supplier in China, offering 0.333V Split CT Current Transformer for Electrical Motor and HVAC, 10A 20A Hall Sensor for Monitoring Current, 0.5 Accuracy 2500: 1 Small Size Power Mini Current Transformer for Outdoor Use and so on.

1
    YRS
General Supplier
Supplier Homepage Electrical & Electronics Sensor Current Sensor 0.333V Split CT Current Transformer for Electrical Motor and HVAC

0.333V Split CT Current Transformer for Electrical Motor and HVAC

Get Latest Price
Min. Order / Reference FOB Price
10 Pieces US $4.80/ Pieces
Local Area: Beijing, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Type: Electromagnetic
Output Signal Type: Digital Output
Production Process: SemiConductor Integrated
0.5-600A 0.333V Transformer Split with ETLTIANJIN GREWIN TECHNOLOGY CO.,LTD.GWSCCTA series split core current transformerPart numberRated input(A)Second output(V)Accuracy classLimit primary current(A)Accuracy classFrequency(Hz)OutlineDimensions ID-L-W-H(mm)Unit weightTurn ratioOutput cableGWSCCT005510150.3331.0 3.0--50-4005.0-25.0-22.5-34.530g3000:1wire(1m)GWSCCT0105,10,20,50,750.3331.0 3.01205P 10P50-40010-29.4-26.4-41.750g3000:1wire(1m)GWSCCT01675,100,1500.3330.5 1.03005P 10P50-40016-36.9-39.2-52.9100g3000:1wire(1m)GWSCCT024100,150,200,2500.3330.5 1.05405P 10P50-40024-51.2-47-70.2250g3000:1wire(1m)GWSCCT035200,300,400,6000.3330.5 1.06005P 10P50-40035-65.8-51.2-83.5400g3000:1wire(1m)
GWSCCTA Series Split Core Current Sensor (Specifications)
Rated Primary current
5-600A
Rated Secondary current
0.333V-3.53V
Rated load
1, 2.5, 5.0, 10, 30VA
Accuracy
0.5, 1.0, 3.0 Class
Rated Short-time thermal current (Ith)
20In
Rated Dynamic current (Idyn)
2.5Ith
Case Material
UL flame retardant rating 94-V0
Highest Voltage for Equipment Um (rms)
720 Vac
Rated Power-Frequency Withstand Voltage(rms)
3,000 Vac
Frequency Range:
50/60Hz
Operating Temperature
-15ºC to 50ºC
Standard
IEC 60044-1
Accessories
Supplied with feet for base mounting if required
Certification
RoHS compliant CE&ETL approved
GWSCCT-ASeries Split Core Current Sensor(Features)
Low cost
5 standard sizes
Split core design, safer, easier installation, and portable
GWSCCT Series Split Core Current Sensor(Applications)
Measures AC current flow to electric motors, lighting, air condition equipment, etc.
Compatible with HVACtemperature control, power management, building
The GREWIN SCCTSA series of split core ct style current sensors are designed for fast and easy installation.The split core design permits non-contactcurrent measurements through magnetic field induction without disconnecting cables or busbar circuits for CT installation. This method permits asafer, easier and portable current measurement.
0.333-3.53V rated secondary output split core current transformer :
Model No 1:GWSCCTA010
Ratio :3000:1
Rated input: 5A 10A 20A 50A 75A
Accuracy class: 1.0s3.0s
Rated primary current :120A
Protection: 5times protection ,10 times protection like 25A 50A 100A 200A 250A 385A 500A 750AModel No.2 :GWSCCTA016
Ratio :3000:1
Rated input: 75A 100A 150A
Accuracy class: 0.5 1.0S
Rated accuracy limit primary current: 300A
Protection :5 times Protection, 10 times protection
Model No. 3:GWSCCTA024
Ratio :3000:1
Rated input: 100A 150A 200A 250A
Accuracy class: 0.5 1.0S
Rated accuracy limit primary current: 540A
Protection :5 times Protection, 10 times protectionModel No.4:GWSCCTA035
Rated input: 200A 300A 400A 600A
Accuracy class: 0.5 1.0S
Rated accuracy limit primary current: 600A
Protection :5 times Protection, 10 times protection
Frequency: 50--400Hz
ConTACT INFO:TIANJIN GREWIN TECHNOLOGY CO.,LTD
Add:Meinian Plaza.No.16 Dongting Road,Hexi Distr,Tianjin,China .