Current Transformer, 0.333V Split Current Sensor, 5A Split Core CT manufacturer / supplier in China, offering 0.333V Split CT Current Transformer for Electrical Motor and HVAC, 10A 20A Hall Sensor for Monitoring Current, 0.5 Accuracy 2500: 1 Small Size Power Mini Current Transformer for Outdoor Use and so on.
Min. Order / Reference FOB Price | |
---|---|
1 Pieces | US $249.00/ Pieces |
Local Area: | Beijing, China |
---|---|
R&D Capacity: | OEM, ODM, Other |
Payment Terms: | LC, T/T, PayPal |
Connectors: | Terminal |
---|---|
Test Mode: | Instant Test |
Usage: | Network Cable Tester, HDMI Cable Tester, Audio Cable Tester, Coaxial Cable Tester, Digital Cable Tes |
Product: 0-8km Measurement Distance Cable Fault Locator Detecting Location for Testing
Introduction
TheTDRL-950 Cable Fault Locator is aportablehandholddevice used for locating the broken fault, cross fault, insulation fault and so on. It can be used to measure the cable length, wave velocity and distinguish the middle joints and terminals.
It is asimple locating device, adopts to kinds cable and specially, thetelecomputercable.
Design Features
lTDRL(Time Domain Reflectometry)method make it possible to measure broken fault, cross fault, insulation fault and so on.
lAutomatic measurement
lAuto power-off when sleeping and low battery voltage
lFriendly user interface, easy to operate
lSupply by dry batter or recharge battery
lHandheld device, easy to carry.
Tech. Specifications
Measurement distance
0-8km
Resolution ratio
0-1km,below 1m;
2km,below 2m;
4-8km,below 8m
Impulse range
30V
Impulse width
80ns-5μs,auto adjustments
Blind zone
1m
Wave velocity range
100-300m/μs
Adjustable gain range
0-80db
Supply power
AA battery x6pcs
Volume
225mmx155mmx50mm
Weight
0.42kgs without battery
Operating Temperature
-10ºC-40ºC
Humidity
5-90%RH
Elevation
<4500m
workingprinciple&Product Structure
Basic working principle
Distance locating:
This device using TDR(Time Domain Reflectometry).When locating,low voltage pulse is injected into and spread along the cable until reach the impedance mismatch point.These points include the short circuit point, fault point,middle connector and so on.When reach these points,the pulse reflection will be send back and record.See Figure.1
Figure 1shows afault point in acable,is the time during transmitted pulse and pulse reflection is received,so fault point distance:
lDeviceconfigurations
T-950 cable fault locator including main engine, testing lines and documents.
lDisplay interface when working
1
ØTransmitted impulse
2
ØBattery lever
3
ØTemporarily storemark
4
ØComparing mark
5
ØCursor
6
ØDistance
7
ØReflection impulse of cable fault point
8
ØWave velocity
9
ØMeasuring range
10
ØGain
11
ØDisplay scale
Application
Fault determined
When cable fault appeared, pls first judge fault feather and broken lever. The TDR fault are divided into three kinds as below:
Disconnection fault: cable broken and communication
disconnect.
Crossing fault which isgenerally classified intothree kinds:
grounding fault, self-crossing fault, and common crossing. During these conditions, theinsulating layerwas broken even touched to affect the communication quality.
Defective insulation fault:
Choose testing range
To get complete testing waveform,the testing range should
be several hundred meters longer than the length of the cable.For example,if the cable is 900m,the testing range should be 2km.when found the fault point closer,reduce the range accordingly.
This device offer below six testing ranges to choose, 125m,
250m,500m,1km,2km and 4km.
Press 1or 2button to change the testing range.Check
'basic function' for reference.
Pls notice that,the device test once automatically after once range changing.
The cable corn is entranced by moisture or water to reduce the insolation resistance.The difference between this and above crossing fault is this has abig resistance, common over thousand Ohms.
In generally, for above first and second fault, it's easy to detect by pulse test, but for the third, user should consider the cable path, time of fault, range of the fault, environment and so on.
Instrument Maintenance Charge
Standard configurationis 6AA NI-MH battery ,capacity above
1300mAH is better.Dry battery is also ok if no NI-MH battery if necessary but need high capacity ones.
*Pleasenotice don't putthe battery backwards.