Business Type:
Manufacturer/Factory
Business Range:
DC/DC Converter, Isolation Amplifier, Data Acquisition Device
Establishment:
2002
R&D Capacity:
OwnBrand, ODM, OEM
Terms of Payment:
T/T, PayPal, WesternUnion
Main Markets:
North America, South America, Europe, Domestic
OEM/ODM Service
Sample Available

Speed Sensor, Speed Sensor Signal Transmitter, Signal Converter manufacturer / supplier in China, offering Vp-P: 200mv-50V to 0-5V Speed Sensor Pulse Signal Isolation Transmitter, 4-20mA Isolation Amplifier Signal Isolator Small Size Transformer, Customized Signal Isolation Transmitter 4-20mA Signal Isolator in 0.1% Accuracy and so on.

1
    YRS
General Supplier
Supplier Homepage Electrical & Electronics Power Transmission & Transformer Instrument Transformer 10kv High Isolation Anti-Static Electric Medical Instrumentation Industry Dedicated DC-DC Converter

10kv High Isolation Anti-Static Electric Medical Instrumentation Industry Dedicated DC-DC Converter

Get Latest Price
Min. Order / Reference FOB Price
1 Pieces US $20.00/ Pieces
Local Area: Shenzhen, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: T/T, PayPal, WesternUnion
Voltage Type: DC Voltage
Input Signal Type: DC Voltage Transmitter
Output Signal Type: Digital Output
The newest WHB series DC/DC Converter developed by SunYuan, It uses wide isulation distance and new isolation material design and comply with the relevant safety regulations of the external RS232/RS485 bus control communication interface in the national electric industry DL/T 614-2007 multi-function energy meter protocol standard, It is a high-isolation & anti-pulse electrostatic dc-dc converter for the intelligent control of the instrumentation equipment bus Ethernet interface commonly used in the electric power medical industry such as power load management terminal, multi-function electric energy meter, blood analyzer, life monitor etc. The SIP12Pin high integration and small size package technology enables the module to have self-recovery overload short-circuit protection and regulated output function.After the electric medical equipment is added to the WHB series dc dc converter, the safety barrier isolation voltage value of the external bus Ethernet (RJ45/RS232/RS485) interface terminal of the instrumentation equipment reaches 10KVDC high isolation and 8KVAC anti pulse group electrostatic protection due to the high isolation between the input and output terminals of the module power supply. Therefore, the WHB series of high isolation dc dc converter can make the equipment and equipment resistant to EMC upgrade and can pass the safety inspection of the electric medical industry.Model&Definision:
Dimensions and pin function description:(Remarks:The 10 feet of the product are the non-functional feet that are suspended inside, which can be used to strengthen the mechanical strength of the module and PCB board.)
Input Voltage
3.3, 5, 9, 12, 15, 24VDC
Output Voltage
3.3, 5, 9, 12, 15VDC
Remarks:
For other non-standard output voltage value specifications, please contact Sunyuan Technology Co., Ltd.
Electrical Characteristics
The following data are measured at TA=25° C, nominal input voltage, and rated output current except for special instructions.
Input Characteristics
Voltage range +/-10% Nominal value
Internal filtering Ceramic capacitors
Isolation Characteristics
Rated voltage 10,000 VDC(about 8000VAC)
Leakage current 1 mA
resistance 109Ohm
capacitance60 pF type.
Ouput Characteristics
Antistatic rating ≥8000VAC pulse goup
Voltage accuracy Output voltage fluctuation range is +/-2% of nominal value(load variation range 0-100%)
( 20 MHz BW) Ripple and noise<50 mVp-p,max
Sustainable short circuit time Output with self-recovery overload short circuit protection
Linear voltage calibration +/- 0.5 % max,(3.3 VDC output +/- 1 % max )
Load voltage calibration+/- 0.5 % typ, +/- 1 % max, (No load to full load)
Temperature Coefficient+/- 0.02 % / °C
External filter capacitor Suggest Co ≤4.7uF,otherwise it will broken easily
General Characteristics
effectiveness60% to 80%
On-off level 60KHz,type.
Environmental Characteristics
Working temperature (environment)- 40° C to + 85° C
storage temperature- 55 °C to + 125 °C
Lower the fixed value See temperature characteristic curve
temperature ≤ 90 %,Uncompressed
cooling method Natural air cooling
Shape Characteristics
SIP (single row in line) package size33.0 x 10.5 x 15.5 mm
1.3 x 0.413 x 0.61 inch
Weight 6g~10g
Shell Material Non-conductive flame retardant black plastic
WHB Series product models selection (The following data is the measured value of the product after 8 hours of continuous full load aging.)
Model numberInput voltage Vin(VDC)Input current
No load (mA)Input Current
Full load (mA)Output voltage Vout(VDC )Output current (max.mA)Full load efficiency (%TYPE)WHB0503H-1W5203173.330363WHB0505H-1W530300520066WHB0512H-1W530260128376WHB0515H-1W532255156778WHB1205H-1W1214126520066WHB1209H-1W1215120911169WHB1212H-1W1215110128375WHB1215H-1W1216115156772WHB2405H-1W24861520068WHB2409H-1W24958911172WHB2412H-1W241270128360WHB2415H-1W24960156769WHB0505H-2W555580540068WHB0512H-2W5354451216789WHB0515H-2W5404951216780WHB1205H-2W1230250540066WHB1209H-2W1228216922277WHB1212H-2W12251981216784WHB1215H-2W12272151513377WHB2405H-2W248119540069WHB2409H-2W248103922280WHB2412H-2W24101001216783WHB2415H-2W2491051513479
Remark: The output efficiency of the output voltage value adjustable product is calculated according to the actual value.Temperature characteristic curve:
Product pressure test notes and test methods:
1,As shown in Figure 1: According to the product isolation voltage specification and set the rated high voltage value, please pay attention to personal safety when testing, beware of electric shock!!!
Test conditions: room temperature TA = 25 ° C, humidity <75%
2,The pressure test operator must wear rubber-insulated gloves and a rubber insulation pad under the seat to prevent high-voltage electric shock.
3,The pressure tester instrument must be grounded reliably and should not be tested in high temperature, humid and dusty environments.
4,The pressure tester must ensure that the high voltage output is "0" and "reset" when connecting the measured object.
5,Do not touch the test object, test line or high voltage output when the instrument is in the startup state or before the test high voltage is released.
6,The product pressure test test method as shown in Figure 1: shorting the input and output pins respectively, and adding isolation voltage between the input and output terminals (DC or AC peak, according to the isolation voltage given by the product), test 1 minute.
7,According to the standard of pressure test, the withstand voltage value is gradually increased from 0, and it is adjusted to the set maximum and maintained at the highest withstand voltage for one minute.
8,The Pressure test itself is a destructive test. The fewer times you should do the better, if the customer needs to test multiple times, the general requirements are: the first time according to the value of the specification, the next time should be correspondingly reduced test the voltage, otherwise the product will be damaged during multiple tests.