Business Type:
Manufacturer/Factory,Trading Company
Business Range:
Lithium Battery
Establishment:
2012
R&D Capacity:
ODM, OEM
Terms of Payment:
LC, T/T, D/P, WesternUnion
Main Markets:
North America, Europe, Australia
OEM/ODM Service
Sample Available

Lithium Battery, Li-ion Battery, LiFePO4 manufacturer / supplier in China, offering 12V 200ah High Energy Storage LiFePO4 Battery (UL, CE, CB, Un38.3), 12V 200ah LiFePO4 Battery Pack for Moveable Solar System (UL, CE, CB, Un38.3), 12V 200ah LiFePO4 Battery for Moveable Solar System (UL, CE, CB, Un38.3) and so on.

1
    YRS
General Supplier
Supplier Homepage Electrical & Electronics Battery, Storage Battery & Charger Battery Pack 12V 200ah High Energy Storage LiFePO4 Battery (UL, CE, CB, Un38.3)

12V 200ah High Energy Storage LiFePO4 Battery (UL, CE, CB, Un38.3)

Get Latest Price
Min. Order / Reference FOB Price
10 Piece US $500.00/ Piece
Local Area: Jiangmen, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, WesternUnion
Type: Lithium-Ion Battery Pack
Connection Mode: Series and Parallel
Rechargeable: Chargeable
Ronda Technical Data SheetLFP12-200 12.8V 201.6Ah 2580.4WhSpecificationsNominal voltage12.8VCapacity(0.2ItA Discharge)201.6AhCapacity(1.0ItA Discharge)201.6AhDimensions522x240x224mmWeight27.2KGCycles
(at 80%DOD, 0.2ItA charge/discharge at ambient temperature in 25±3ºC.)2000cyclesTerminal TypeseelayoutOperating temperature rangeStorage-20~+45ºCStandard Charge (<=0.2ItA)0~+60ºCQuick Charge ( >0.2ItA)+10~+60ºCDischarge-20~+70ºCStorageCapacity loss at 25 ºC1 month5%3 months10%6 months15%Case materialStandard ABS(UL94HB)FR version available UL94V0Charge RegimeCC-CV until current less than0.02ItACharge voltage14.6V(±3%)Discharge voltage8~10VCharge currentMax.120ADischarge currentMax.120AOver current protection & internal resistanceOver current protection(Short-circuit)350±50AInternal resistance110mΩDesign life at 25ºC3-5YearsApplications: (Lead-acid battery replacement)Solar light /Solar power system/ UPS system/ Emergency light/ Wind energy storage/Medical device/moveable solar system/traffic signal
Safety
Installation
Can be installed and operated in any orientation except permanently inverted.Handles
Batteries must not be suspended by their handles (where fitted).
Warning
Do not charge the batteries in series connecting;
Do not short-circuit the battery terminal;
Do not heat, drop, disassemble or crush the battery;
Do not expose the temperature above 70ºC;
Use specified charger only.
Recycling
Ronda's batteries must be recycled at the end of life in accordance with local and national laws and regulations.