seline;">Product introduction
The anesthesia machine uses compressed oxygen and nitrous oxide from a gas cylinder or central gas supply system at the hospital. The compressed oxygen and nitrous oxide from the central gas supply system are both at a pressure of 0.4MPa. After oxygen and backup oxygen are combined by a one-way valve and then split into two flows, one is connected to an oxygen flush valve, and the other flow is depressurized to 0.3 to 0.35MPa by a pressure regulator and then enters a flow meter and is connected with an oxygen fault alarm. The laughing gas is depressurized to 0.25 to 0.30MPa by a pressure regulator and then enters the flow meter. The pressure of the gas from the gas cylinder or central oxygen supply system may vary with the temperature and air storage. The purpose of the pressure regulator (also called reducing valve) is to stabilize the gas pressure and meet the need of the anesthesia machine.
SPECIFICATIONS FOR ANESTHESIA MACHINE MSLGA10
Gas requirement
Medical oxygen and nitrous oxide with a pressure ranging from O2: 0.32~0.6MPa ; N2O: 0.32 MPa to 0.6 MPa
Safety valve
<12.5 kPa
Respiratory Rate
4~40bpm
Flow meter
O2:0.1~10L/Min, N2O:0.1~10L/Min
Oxygen concentration in the mixed gas N2O/O2
> 21%
Oxygen Flush
25~75 L/min
Modes of ventilation
A/C,IPPV, SIPPV, MANUAL
I/E Ratio
1:1.5; 1:2.0; 1:2.5; 1:3
Tidal Volume
0~1500ML
Maximum safety pressure
Max. Gradeability
Controlled ventilation and assisted ventilation switching time
6s
Pressure limit range
0 ~ 6.0 kPa
Vaporizers
2
Tidal volume alarm
upper alarm: 50 to 2000ml,lower alarm: 0~1800ml
Airway pressure alarm
Lower: 0.2kPa~5.0kPa; Upper: 0.3~6.0 kPa
Power Supply Alarm
Ac/dc power supply are after failing to send out alarm immediately
Alarm Time: keep >120s