Business Type:
Group Corporation
Business Range:
Miniature Circuit Breaker, Moulded Case Circuit Breaker, Air Circuit Breaker, Oil-immersed ..
Establishment:
1995
R&D Capacity:
ODM, OEM
OEM/ODM Service
Sample Available

Panel Meter, Ac Amp Panel Meter, Voltage Meter manufacturer / supplier in China, offering 96 Series Indicator Measure Panel Meter/AC AMP Panel Meter, Ddsy726 Single Phase Electronic Prepayment Kwh Energy Meter, 2019 Best Quality Three Phase Digital Panel Ammeter Voltmeter and so on.

1
    YRS
General Supplier
Supplier Homepage Service Other Service 96 Series Indicator Measure Panel Meter/AC AMP Panel Meter

96 Series Indicator Measure Panel Meter/AC AMP Panel Meter

Get Latest Price
Min. Order / Reference FOB Price
100 Piece US $1.00/ Piece
Local Area: Wenzhou, Zhejiang, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Specification: CE
Trademark: CNC
Origin: China
96 Series Indicator measure Panel Meter/ac amp panel meter
96 TYpe Panel Meter/ac amp panel meter
CNC, Changcheng- China Famous Brand
www.cncele.com
Panel meter is one kind of electric measure indicators with the direct effecting of imitative display. It is suitable for AC and DC output and input distribution circuit, power plant console cabinet, power operating board and different apparatus. It is used to measure DC current, voltage and AC current, voltage, frequency and phase power.
Type:
OB-96 2MD
96 type Maximum Demand vector table (three needle table)
Accuracy class: 3.0, Instantaneous ammeter 1.5 degree
Specification: 8 minutes 1A, 15 minutes 1A, 30 minutes 1A, 8 minutes 5A, 15 minutes 5A, 30 minutes 5A (As long as the input signal is the same, the dail can arbitrary change according to the change of transformer, accuracy unchanged).
OB-96 H
96 type Cumulative schedule
Maximum display: 99999.99
Voltage: DC12V, 24V; AC110V, 220V, 380V
Frequency: 50/60Hz
OB-96 L DC A
96 type 240° Electromagnetic Series (moving coil) DC Ammeter
Accuracy class: 1.5
Specifications: 100uA 150uA 500uA 1mA 2mA 5mA 10mA 20mA 30mA 50mA 75mA 100mA 150mA 200mA 250mA 300mA 500mA 1A 2A 3A 7.5A 10A 15A
More than 20A connecting 50mV,60mV or 75mV of shunt Outside.
OB-96 L DC V
96 type 240° Electromagnetic Series (moving coil) DC Voltmeter
Accuracy class: 1.5
Specifications: 50mV 60mV 75mV 100mV 3V 5V 7.5V 10V 15V 20V 30V 50V 75V 100V 120V 150V 200V 250V 300V 400V 450V 500V 600V, More than 600V connecting with Quota Resistors (Rated current 5mA)
OB-96 L Hz
96 type 240°Frequency Table
Accuracy class: 1.0
Voltage: 110V, 220V, 380V, 415V, 440V
Frequency: 45-55Hz, 45-65Hz, 55-65Hz, 47-53Hz, 57-63Hz, 450-550Hz, 450-650Hz, 550-650Hz.
OB-96 Hz
96 type Vibrating reed Frequency Table
Accuracy class: 1.0
Voltage: 110V, 220V, 380V, 415V, 440V
Frequency: 45-55Hz, 45-65Hz, 55-65Hz, 47-53Hz, 57-63Hz
OB-96 COS
96 type Power Factor Meter
Accuracy class: 2.5
3 phase voltage: 110V, 220V, 380V, 415V, 440V/1A or 5A
Single phase voltage: 110V,220V/1A or 5A
Frequency: 50/60Hz
Specification: 0.5cap-1-0.5ind
OB-96 KW
96 type Power Meter
Accuracy class: 1.5
Single phase voltage: 100V, 110V, 220V
Three-phase three-wire voltage: 100V, 110V, 220V, 380V, 415V(Balanced load or unbalanced load)
Current: Input Current more than 10A connecting inferior 1A or 5A of current
tranformer outside, otherwise allowing direct access according to the current value.
Frequency: 50/60Hz
Specification: 100W, 200W...1KW, 2KW...1MW, 2MW...6MW.
OB-96 KW
96 type Power Meter
Accuracy class: 1.5
Three-phase four-wire voltage: 100V, 110V, 220V, 380V, 415 (Balanced load or unbalanced load)
Current: Input Current more than 10A connecting inferior 1A or 5A of current tranformer outside, otherwise allowing direct access according to the current value.
Frequency: 50/60Hz
Specification: 100W, 200W...1KW, 2KW...1MW, 2MW...6MW.
OB-96 MD
96 type Maximum Demand vector table (double needle table)
Accuracy class:3.0
Specification: 8 minutes 1A, 15 minutes 1A, 30 minutes 1A, 8 minutes 5A, 15 minutes 5A, 30 minutes 5A (As long as the input signal is the same, the dail can arbitrary change according to the change of transformer,accuracy unchanged)
OB-96 2MD
96 type Maximum Demand vector table (three needle table)
Accuracy class: 3.0, Instantaneous ammeter 1.5 degree
Specification: 8 minutes 1A, 15 minutes 1A, 30 minutes 1A, 8 minutes 5A, 15 minutes 5A, 30 minutes 5A (As long as the input signal is the same, the dail can arbitrary change according to the change of transformer, accuracy unchanged).