Business Type:
Manufacturer/Factory
Establishment:
2012
R&D Capacity:
ODM, OEM, Other
OEM/ODM Service
Sample Available

Gas Meter Bench, Sonice Nozzle, Sonice Nozzle Test Bench manufacturer / supplier in China, offering Sonic Nozzle Gas Meter Test Bench, Wa10-Dn15-50mm Automatic Water Meter Test Bench, Dn15-25mm Automatic Water Meter Test Bench and so on.

1
    YRS
General Supplier

ANSI Energy Meter Testing Bench

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $6000.00/ Piece
Local Area: Shanghai, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Form 1s: Form 2s
Reference Standard Meter: Sp-5100
Application: Test and Measurement Instruments
ANSI SOCKET SINGLE PHASE METER CALIBRATION BENCHFeatures
1) The bench accords with the standard of " IEC 60736:1982 testing equipment for electrical energy meters", "IEC 62053","ANSI C12.7-2005 Requirements for Watt-hour Meter Socket",
2) The bench can be used to test single phase energy meter (up to 0.2 class), include Form 1S(closed I-P links) & Form 2S (opened I-P links) energy meter.
3) The bench can do warm up testing, startup testing, no load testing(creep testing), error testing(accuracy testing), dial testing, testing of the influence quantities and testing of repeatability of the measurements, etc.
4) The bench is using the PWM technology to amplify voltage/current output, the high efficiency at >85%, and lower the heat. The PWM can check the malfunction checking, preset, alarm, and protection.
5) The signal source is using the newest digital controlled sine wave technology for frequency, amplitude and phase adjust.
6) The bench is using comparison technology to test the error of energy meters.
7) The bench is using the error processor system to calculate the error of each energy meter by the sub-error system which can be connected by the internal RS485.
8) Different constant energy meter can be tested at one time.
9) Voltage is isolated by MSVT (multi secondary voltage transformer) output, which suits for the voltage & current closed I-P links testing of Form 1S energy meter.
Technical Specification
1) The test bench accuracy class: 0.05 class
2) Reference standard energy meter:
SP-5100 single phase reference standard energy meter
Accuracy class: 0.05
3) MSVT(multi secondary voltage transformer) class: 0.01
Secondary voltage: 60-300V
Secondary VA rating: 15VA per winding
Insulation secondary to secondary: 500V, 50Hz, 60 seconds
Secondary to secondary ratio accuracy less than : ±0.01%
Secondary to secondary phase angle accuracy less than ±1 minute
Number of secondary output: 3~60channel
Dimension:Type of benchMeters Number of rackNumber of rowSize of rackIntegration6
10
201
1
1Single
Single
Double1600x800x1600 mm
2200x800x1600 mm
2200x800x1920 mmFission10
201
1Single
Double2200x700x1600 mm
2200x700x1920 mmSize of Console: 600x800x1600 mm