Business Type:
Manufacturer/Factory
Establishment:
2012
R&D Capacity:
ODM, OEM, Other
OEM/ODM Service
Sample Available

Chilled Water Producer, Ice Chillers, Falling Film Heat Exchanger manufacturer / supplier in China, offering Pillow Plate Heat Exchanger Falling Film Evaporator Instant Chiller 0.5 Degree, Plate Heat Exchanger Falling Film Water Cooler Chillers in Fruit Juice Processing Plant, Immersion Plate Falling Film Heat Exchanger in Fruit Juice & Pulp Processing Plant and so on.

1
    YRS
General Supplier
Supplier Homepage Industrial Equipment & Components Refrigeration Equipment Condenser All Welded Plate Type Evaporative Condenser for Cold Room Storage Condensing Unit

All Welded Plate Type Evaporative Condenser for Cold Room Storage Condensing Unit

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $23000.00/ Piece
Local Area: Jian, Jiangxi, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Condensation Forms: Evaporative Cooling
Refrigerant: R407A
Type: Evaporative Condenser

Sehenstar Plate Type Evaporative Condenser is a kind of high-efficient heat exchange equipment which comes into being on the basis of absorbing the most advanced heat-exchange technology.
The Evaporative Condenser uses water and air as cooling medium. The cooling medium exchanges the heat with high-heat gaseous refrigerant medium and hence the refrigerant medium becomes liquid. Inside, there are water dispatching system, condensing plate, wet padding heat exchange layer, and so on. Outside, there are water circulating pump, an electronic water-curing device and a propeller fan on the top of condensing plate. The propeller fan strengthens the flow of the air and causes negative pressure inside.When the condenser works, the cooling water is sprayed from water dispatching system to the surface of condensing plate equably to form a thin layer of water film. The high-heat steam of refrigerant medium enters from the top of condensing plate and then the cooled liquid refrigerant medium is discharged from the bottom of the condensing plate. During this process, high-heat refrigerant medium exchanges the heat with the water and air outside the plate and increases the efficiency of medium exchange with the help of wind.After absorbing the heat of refrigerant medium, some water turns into steam and is discharged by propeller fan. Meanwhile, the moisture in the air is collected by dehydrator to collecting basin, and then the non-gasified cooling water flows into heat exchange layer and its heat is taken away by the airflow. The cooled water converges in the basin to be used circularly by the pump later. In addition, there is a ball cock in the basin. When the water is consumed to a certain point, the ball cock will automatically open to replenish the cooling water.