Ambulance Use Multi Parameter Patient Monitor PC-3000

Get Latest Price
Min. Order / Reference FOB Price
1 Piece Contact Supplier
Local Area: Zhengzhou, Henan, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Medical Device Regulatory Type: Type 1
Customized: Non-Customized
Certification: CE, FDA, ISO13485
Ambulance Use Multi Parameter Patient Monitor PC-3000
Main Paramter:- 7'' high resolution colour TFT display, 5-channel waveform display- standard parameters: ECG, RESP, SpO2 , NIBP, TEMP, PR; Arrhythmia analysis and ST segment analysis- up to 800 groups parameter data & 24-hour ECG waveform storage and recall- 480-hour graphic and tabular trends for all parameters- 7-channel ECG simultaneous waveforms display- protection against interference from defibrillator, electrosurgical knife- adult / Pediatric measurement modes- visual and audible alarms; networking capability
STANDARD ACCESSORIES1 ECG cable1 NIBP cuff1 SpO2 probe1 Body surface temperature transducer1 Power cable1 AC power Adapter10 Disposable electrodes1 Li-ion batteryUser manual TECHNICAL SPECIFICATIONSECG MonitoringHeart rate measurement: ±0.4mVp~±5mVp
Heart rate display range: 20bpm~250bpm
Display accuracy*: ±1% or ± 2 bpm, whichever is greater
Heart rate alarm delay time: ≤10s
Sensitivity selection: Auto, x1/2, x1, x2, x4 tolerance: ≤5%
Sweeping speed: 12.5 mm/s, 25mm/s, 50mm/s tolerance: ≤10%
ECG noise level: ≤30μVP-P
ECG input loop current: ≤0.1μA Input impedance: ≥5MΩ
Common-mode rejection ratio: ≥89dB
Time constant: Monitoring mode≥0.3s
Diagnostic mode≥3.2s
Frequency response: Monitoring mode: 0.5Hz~25Hz
Diagnostic mode: 0.05Hz~75HzNIBP Monitoring Measuring method: Automatic measurement by oscillating method
Cuff inflation time: <10 seconds (typical adult cuff)
Initial cuff inflation pressure: Adult mode: <180mmHg infant mode: <120mmHg
Overpressure protection limit: Adult mode: 300mmHg Infant mode: 240 mmHg
Measuring range
Systolic pressure: Adult: 40-225 mmHg Infant: 40-200 mmHg
Diastolic pressure: Adult: 20-215 mmHg Infant: 20-165 mmHg
Mean arterial pressure: Adult: 10-195 mmHg Infant: 10-150 mmHg
Measurement accuracy: Systolic ±10% Diastolic ±10% MAP ±10%
Measurement mode: Manual, Auto, STAT
Automatic measuring: 1~240min Intervals:
interval tolerance: <10s
SpO2 & Pulse Rate MonitoringTransducer: dual-wave length LED
SpO2 measuring range: 35%~100%
Low perfusion capability: 0.4%~5%
SpO2 display accuracy: 70%~100% ±3%
PR measuring range: 30bpm~250bpm
PR measuring accuracy: ±2bpm
TEMP MonitoringMeasuring range, accuracy: 25.0°C~45.0°C, ±0.2°C