Business Type:
Trading Company
Business Range:
ECG machine, B ultrasound machine, Endoscope camera systems, Patient Monitor, Ultrasound for vet
Establishment:
2016
R&D Capacity:
OEM, ODM, Others
Terms of Payment:
LC, T/T, D/P, Paypal, Western Union
Main Markets:
Domestic Market, Africa, Southeast Asia
OEM/ODM Service
Sample Available

We ar a leading medical equipment manufacturer that is located in the Optical Valley of Hubei Province, the center of China.We founded in 2005, is devoted to the development of Ultrasound Imaging Syst...

1
    YRS
General Supplier
Supplier Homepage Furniture Outdoor Furniture Ambulance emergency ICU CCU medical ventilator machine with air compressor

Ambulance emergency ICU CCU medical ventilator machine with air compressor

Get Latest Price
Min. Order / Reference FOB Price
1 Unit US $5500.00/ Unit
Local Area: Wuhan, Hubei, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, Paypal, Western Union
Brand: Visbull
Place of Origin: Hubei, China
Instrument classification: Class II
Product name: ICU ventialtor machine, medical ventilator machine, ventilator machine

Ambulance emergency ICU CCU medical ventilator machine with air compressor

Product Description

The PA-900B II ventilator is gas driven by medical compressed oxygen and compressed air. In the inspiratory phase,

two streams of compressed gas (compressed oxygen and compressed air) flow into a high performance air-oxygen mixer to form a mix of oxygen and air with a certain pressure.

Physical specifications Display 10.4'' LCD DisplayMode:pneumatically powered and electrically controlled systemWorking Mode:Closed; Semi-Closed; Semi-OpenTrolley:

Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability

with foot operated brake provisions

Technical Specifications:Gas requirement: Medical oxygen and nitrous oxide with a pressure ranging from 280~600kpasafety valve <12.5 kPaRespiratory Rate1bpm~99 bpmgas concentration output21% ~ 100% adjustableMaximum Minute ventilation≥18L / min, permissible deviation: ±20 %Breathing ModeA/C, SIPPV,IPPV,SIMV,PSIMV,CPAP,PCV,PEEP,SIGN,SPONT, MANUALVentilator compliance: ≤30 Ml/kPaPEEP:0~1.0KPaPtr: ,-1.0~1.0 kPaIMV frequency:1 ~ 12 times/min, permissible deviation: ±15%.I/E Ratio:4:1~1:4Tidal Volume range0~2000ml resolution ratio: 10mlInspiratory Plateau:0~1sMaximum Safety Pressure≤ 6.0kPaSigh:

one deep breath per 80 controlled respirations, the inspiration time is 1.5 times of the setting

point and the permissible error is -10% or 15%.

Pressure limit range:1.0~ 6.0kPa

Airway pressure alarm: Audible and

visual and with yellow and

red color indicating

upper alarm: 0.9 kPa ~ 5.4 kPalower: 0.5kPaVentilation Volume alarm: ≥ 18L/ MIN Power Supply AlarmAc/dc power supply are after failing to send out alarm immediately
Alarm Time: keep >120s

The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine

will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on

the screen of the anesthetic respirator.

Operating conditionsAmbient temperature: 10 ~ 40oCRelative humidity:no higher than 80 %Atmospheric pressure:860 hPa ~ 1060 hPaPower requirement: 100-120 Vac, 50/60 Hz; Air source requirement: Medical oxygen and laughing gas with a rated pressure ranging from 0.3 to 0.5MPa.Attention: the AC power supply used for the anesthesia machine must be wellgrounded.

Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an

oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical

Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System.

StorageAmbient temperature: -15oC ~ +50oCRelative humidity: no higher than 95 %Atmospheric pressure: 86 kPa ~ 106 kPa. It should be stored in a room without corrosive gas and well ventilatedPackagepackaging boxcomply with the requirement of GB/T 15464

Between the packaging box and product, soft material with appropriate thickness

provided to prevent loosening and mutual friction during transportation

Moisture protection and rain protection to ensure that product is protected from natural damage. Safty & AlarmGas source pressureImmediate alarm; “high level alarm” indicator flickers raising an audible alarm.Airway Pressure Alarm

The airway pressure exceeds 15hpa. The maximum delay is no longer than 17s.

The “high level alarm” indicator flickers raising an audible alarm.

Tidal Volume AlarmLower than 50ml, The alarm will be raised after one breathing cycle. Ventilation Volume AlarmLower: 0~12L/Min;Up: 18L/ MinBattery Voltage AlarmIt alrms when the battery voltage is lower than 10.5V.Power On Self TestSelf test before working, assure it's working normally.

Air Compressor Power: AC220V + 22 v, 50 Hz + 1 Hz and 300 va has a good reserve of single-phase ac power supply FUSE :Φ 5 x 20 / F8A Output gas pressure: 0.3 ~ 0.4 MPa Output gas minimum flow: ≥50L/Min Output gas transient flow: ≥100L/Min

Products Show

Ambulance emergency ICU CCU medical ventilator machine with air compressor

Packaging & Shipping

Ambulance emergency ICU CCU medical ventilator machine with air compressor

Our Services

Ambulance emergency ICU CCU medical ventilator machine with air compressor

Company Information

Ambulance emergency ICU CCU medical ventilator machine with air compressor

FAQ

Ambulance emergency ICU CCU medical ventilator machine with air compressor

ConTACT US

Ambulance emergency ICU CCU medical ventilator machine with air compressor

Janice Leung

Sales

Add: Room 521, Building 3, Mingshiyihao, Shucheng Road, Hongshan District, Wuhan, Hubei Province, China

Mobile/Whatsapp/Wechat: +86 13422568280

Tel: +86 27 87103315

Skype: janice_leung36