Business Type:
Manufacturer/Factory
Establishment:
2012
R&D Capacity:
ODM, OEM, Other
OEM/ODM Service
Sample Available

Current Transformer, Split Core Current Transformer, Split Current Transformer manufacturer / supplier in China, offering Waterproof Outdoor Split Core CT Current Transformer for Power Meter, 500/5A Split Core CT Current Transformer, 2500 AMP Accu CT Split Core Current Transformer 333mv Sensor and so on.

1
    YRS
General Supplier
Supplier Homepage Instruments & Meters Electronic Instrument Calibrator Automatic Class 0.02 China High Quality Current Transformer CT Analyzer

Automatic Class 0.02 China High Quality Current Transformer CT Analyzer

Get Latest Price
Min. Order / Reference FOB Price
1 Set US $15.00/ Set
Local Area: Chaoyang, Liaoning, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Application: Electromagnetic Instrument
Power: Electricity
Certification: FDA, CE, IAF, CCC
GF106 PORTABLE 0.02% high accuracy DC method current transformer testing ct analyzer
GF106 portable CT analyzer is mainly used for field or lab testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data. The CT PT Analyzer is the most complete and easy-to-use testing system for protection and metering CTs according to IEEE and IEC standards.
The CT Analyzer automatically determines all relevant current transformer values and compares the results with the selected standard. The device evaluates the current transformer as per the IEC or IEEE standard within seconds with the push of a button.
It facilitates fast and economical on-site testing and calibration of metering and protection current transformers. Manufacturers of current transformers, high voltage transformers and switchgear also use the CT Analyzer for tests during development and production.Applications
The following values can be determined using the CT Analyzer:
Accuracy of the ratio and phase angle, taking into consideration the nominal burden and connected burden
CT excitation and saturation
Burden impedance
Winding resistance
Saturated and non-saturated inductance
CT polarityMAIN FUNCTIONSI. Current Transformer (CT)II. Voltage Transformer (PT)1. Magnetization curve1. Excitation characteristic test2. Transformation ratio test2. Transformation ratio test3. Polarity3.Polarity4. 5% and 10% error curve4. Ratio error, phase error5. Accuracy limiting factor (ALF)5.Degauss6. Degauss6. Calculation of knee point value7. Ratio error, phase error7. Actual secondary load test (burden test)8. Automatic calculation of excitation knee point value8. Resistance test9. Actual secondary load test (burden test)10. Resistance test11. Secondary time constant (Ts)12. Remanence coefficient (Kr)13. Transient dimensioning factor (Ktd)14. Peak instantaneous error (Er)15. Magnetizing inductance (LU)16. Instruments security factor(FS)17. Composite errorPARAMETERSElectrical parametersAccuracy0.2%, 0.5%Power supplyAC 220V±10% or AC 110V±10%, 50/60HzExcitation voltage output0-2500Vrms,Excitation current output0-5Arms (20A peak-value)Large current output0-1000AElectrical parameters - continuedAccuracy≤0.5% (0.2%RD+0.3%RG)Secondary winding DC resistance measurementRange0.1-300ΩAccuracy≤0.5% (0.2%RD+0.3%RG)Secondary actual load measurementRange5VA-1000VAAccuracy≤0.5% (0.2%RD+0.3%RG)±0.1VACT/PT phase error measurementAccuracy±4minResolution0.01minCT ratio error measurementRange5-25000A/5A(5000A/1A)Accuracy≤0.5%PT ratio error measurementRange1-500KVAccuracy≤0.5%StandardsReference standardsGB1207-2006, GB1208-2006, GB16847-1997
IEC60044-1, IEC60044-6, IEC61869-2-2012Safety standardsGB 4793.1-2007EMCEMC standard 89/336/EECFCC Subpart B of Part 15 Class AIEC 1000-4-2 /3 /4 /6Mechanical parametersOverall dimension (L x W x H) (mm)400 x 240 x 260Weight (kg)≤23Environmental conditionsRelative humidity90RH%Operating temperature-10°C to +40°CAltitude≤1000mElectrical parametersAccuracy0.2%, 0.5%Power supplyAC 220V±10% or AC 110V±10%, 50/60HzExcitation voltage output0-2500Vrms,Excitation current output0-5Arms (20A peak-value)Large current output0-1000AElectrical parameters - continuedAccuracy≤0.5% (0.2%RD+0.3%RG)Secondary winding DC resistance measurementRange0.1-300ΩAccuracy≤0.5% (0.2%RD+0.3%RG)Secondary actual load measurementRange5VA-1000VAAccuracy≤0.5% (0.2%RD+0.3%RG)±0.1VACT/PT phase error measurementAccuracy±4minResolution0.01minCT ratio error measurementRange5-25000A/5A(5000A/1A)Accuracy≤0.5%PT ratio error measurementRange1-500KVAccuracy≤0.5%StandardsReference standardsGB1207-2006, GB1208-2006, GB16847-1997
IEC60044-1, IEC60044-6, IEC61869-2-2012Safety standardsGB 4793.1-2007EMCEMC standard 89/336/EECFCC Subpart B of Part 15 Class AIEC 1000-4-2 /3 /4 /6Mechanical parametersOverall dimension (L x W x H) (mm)400 x 240 x 260Weight (kg)≤23Environmental conditionsRelative humidity90RH%Operating temperature-10°C to +40°CAltitude≤1000mhttp:https://www.split-core-current-transformer.com/sale-8693899-0-02-high-accuracy-dc-method-current-transformer-testing-ct-analyzer.html