Environmental and Climatic Simulation Test Chamber, Mechanical Tester, Ultra Freezers
Establishment:
2016
R&D Capacity:
ODM, OEM
Terms of Payment:
LC, T/T, PayPal, WesternUnion
Main Markets:
North America, South America, Europe, Southeast Asia, Middle East, Australia, Domestic
OEM/ODM Service
Sample Available

Test Chamber, Testing Machine, Test Equipment manufacturer / supplier in China, offering Air Cooled Environmental High Low Temperature Test Chamber, Environmental Laboratory Hot and Cold Temperature Cycling Thermal Shock Test Machine Price, Environmental High Low Temperature Impact Machine Thermal Shock Test Chambers and so on.

1
    YRS
General Supplier
Supplier Homepage Instruments & Meters Test Instrument Battery Tester Battery Explosion Proof Testing Chamber Price

Battery Explosion Proof Testing Chamber Price

Get Latest Price
Min. Order / Reference FOB Price
1 Sets US $5.00/ Sets
Local Area: Dongguan, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal, WesternUnion
Type: Finished Batteries Tester
Test Region: All
Application: Lithium-ion Battery
Battery Explosion Proof Testing Chamber Price
Product Application:
1.High and low temperature (explosion) test box is mainly used for making a test evaluation anddeterminingthe nickel cadmium battery, nickel metal hydride batteries, lithium ion batteries, lead-acid batteries, lithium batteries, etc., At the climaticofthe high and low temperature resistance, temperature shock, temperature and humidity conditions' storage and use of adaptability, high and low temperature (explosion) test chamber is suitable for auto parts factory, battery factory, energy dynamics, military industry, R & D and so on.2.High and low temperature (explosion-proof) test box is suitable for testing lithium ion, nickel metal hydride, nickel cadmium, lead acid, nickel metal hydride and other types of single battery and battery pack. According to the StandardGB8897.4-2002(idt IEC60086-4:2000)<pirmary battery- part 4: safety requirements for lithium batteries>;GB8897.5-2006(idtIEC60086-5:2005) <pirmarybattery- part 5: safety requirements for aqueous electrolyte batteries>;IEC 62133:2002 <Alkaline and or other non-acidic electrolyte secondary batteryand battery pack portable seal secondary battery and battery pack safetry requirement>;IEC61951-1:2003 <contain alkaline or other non-acidic electrolytes' portable seal rechargeable battery and battery pack part 1:nickel-cadmium battery>;IEC61951-2:2003<contain alkaline or other non-acidic electrolytes' portable seal rechargeable battery and battery pack part 2:metal hydride>;IEC61960:2003<Alkaline and or other non-acidic electrolyte secondary battery and battery pack portable secondary Li battery and battery pack>;UL1642:2006<Li storage battery> makingthermal abuse (extremely high temperature) and thermal shock test projects
Explosion Proof Temperature Humidity Test Chamber for battery
Controller SH-5600,The control panel is provided with USB or RS232 port, a battery surface
temperature detectiondisplay light( will be divided into three level alarm), a battery fault alarm
reminder, a harmful gas alarm, an exhaust indication light, an emergency stop switch, outfire
indication light and over temperature protection.Temperature and Humidity Test Chambers
provides an economical and space-saving solution for a variety of testing requirements.It can
simulate different climatic conditions, such as heat-endurance, cold-endurance, dryness-endurance,
and humidity-endurance, which defines the Performance of material. By testing the product under
different climatic conditions to see whether its performance can meet the intended requirements.
It is widely applied in the industries of electron, electrical equipment, vehicle, metal, food, chemistry,
building materials, luggage, adhesion tape, printing,packaging, and other product components and
materials.The programmer includes a temperature alarm as just one part of Grande's Three-tiered
over-temperature protection system. A thermal fuse and a user-set independent limit are also included.
In addition, a specimen power terminal allows the user to safely operate powered equipment inside or with the chamber.
Corresponding Standard of the Temperature and Humidity Test Chamber:
1.GB11158 high-temperature testing condition
2.GB10589-89 low-temperature testing condition
3.GB10592-89 high-low-temperature testing condition
4.GB/T10586-89 humidity testing condition
5.GB/T2423.1-2001 low-temperature testing condition
6.GB/T2423.2-2001 high-temperature testing condition
7.GB/T2423.3-93 humidity testing condition
8.GB/T2423.4-93 alternating temperature testing machine
9.GB/T2423.22-2001 temperature testing method
10.IEC60068-2-1.1990 low-temperature testing method
11.IEC60068-2-2.1974 high-temperature testing method
12.GJB150.3 high-temperature test
13.GJB150.4 low-temperture test
14.GJB150.9 humidity test
Grande Expertise in Humidity ControlControlling humidity in a small environmental chamber can be especially challenging. Grande expertise
in humiditycontrol brings intelligent design that is carefully integrated into the Criterion chambers. The
humidity subsystems
are designed for reliability, convenience, and performance:
An external steam generator allows expanded range and is easy to maintain.
A separate de-humidification coil improves low humidity control and range.
Wet-bulb humidity sensor is a "primary measurement method" for accuracy. It is also economical, easy to
maintain,and reliable because it has no risk of failure due to over-saturation. (Read why analog is preferred
over digital.)
Direct water supply connection is standard, with options for water filtering and recirculating water tank.
Features
High performance and quiet operation (65 dBa)
Space-saving footprint, designed for flush installation to wall
Stainless steel exterior
Full thermal break around doorframe
One 50mm (2") diameter cable port on left, with flexible silicone plug
Three levels of overheat protection, plus overcool protection
Easy lift-off service panels, electrical access on left
Detachable eight-foot power cord with plug
Direct water supply connection for continuous operation (supply tank optional)
Over-heat protection circuit breaker,Compressor overload protection,Control system overload protection,
Humidifying system overload protection,Overload indicator lamp.Specification:Model No GTH-080GTH-150GTH-225GTH-408GTH-800GTH-1000Working room(L)801502254088001000Inner chamber size(mm)W*H*D 400*500*400500*600*500500*750*600600*850*8001000*1000*8001000*1000*1000Exteriorchamber size(mm)W*H*D900*900*1500950*1500*1050950*1650*11501050*1750*13501450*1900*13501450*1900*1550Packaging volume(CBM)233.54.55.56G.W.(KGs)300320350400600700PerformanceTemperature range-80ºC,-70ºC,-60ºC,-40ºC,-20ºC,0ºC~+150ºC,200ºC,250ºC,300ºC,400ºC,500ºCHumidity range20%RH~98%RH(10%RH~98%RH or 5%RH~98%RH)Temp.&Humi fluctuation±0.2°C, ±0.5%RHTemp.Humi.Uniformity ±1.5°C; ±2.5%RH(RH≤75%),±4%RH(RH>75%) No-load operation,After stead state 30 min.Temp.humi resolution0.01°C; 0.1%RHHeating up time°C100 150Min30 4030 4030 4530 4530 4530 45Cooling down time°C0 -20 -40 -60 -70Min25 40 50 70 80Heating rate≥3°C/min Cooling rate≥1°C/minMaterialInner chamber materialSUS#304 stainless steel plateExterior chamber materialSUS304 Stainless steel plate+ powder coatedInsulation MaterialPU & Fiberglass woolSystemAir circulation systemCooling fanFanSirocco fanHeating SystemSUS#304 stainless steel high-speed heaterAir flowForced Air Circulation(It enters at bottom and leaves at top)Humidification systemSurface evaporation systemRefrigeration systemimported compressor,French Tecumseh compressor or German Bitzer compressor,finned type evaporator,air(Water)-cooling condenserRefrigerating fluidR23/ R404A USA Honeywell.CondensationAir(Water)-cooling condenserDehumidifying system ADP critical dew point cooling/dehumidifying methodControlling systemPID Digital electronic indicators+S.S.R.With PID automatic calculation capabilityOperation interfaceGrande Expertise in Temperature & Humidity Controller,Chinese-English Shift.ControllerProgrammable capability Save 120 profiles with up to 1200 steps eachSetting rangeTemperature:-100ºC+300ºCReading accuracyTemperature:0.01ºCInputPT100 or T SensorControlPID controlCommunication interfaceEquipped with standard communication interface devices USB,RS-232 and RS-485,enable the test chamber to be connected with personal computer(PC),to achieve multi-machine control and management at the same time.Standard: USB external memory port.Optional: RS-232, RS-485, GP-IB, EthernetPrint functionJapan Yokogawa Temperature Recorder(Optional accessories)AuxiliaryLimit Alarm,Self Diagnosis,Alarm Display(Failure Cause),Timing device(Automatic Switch)Explosion Proof SystemStandard configuration2 Ø100MM pressure relief port, 4 explosion-proof chains
Explosive pressure relief device
When the pressure in the equipment or pipeline exceeds the safety valve pressure relief automatically open Equipped with:Bursting disc,protective cover,sensor switch,exhaust fan function:When the test items explode,there is a pressure release pipeProtect the test equipment from sudden air pressure damageC.Protecting the human beings and propertyMultipoint temperature
monitorAdopts Grande developed controller, which can be used to acquire surface temperature points of multiple productsCO2 fire extinguisherAutomatic fire extinguishing and automatic shutdown of the machine to protect the equipment from burningCO & H2 gas detectorWhen the battery will produce gas, it will detect gas solubility and discharge to outdoor when it exceeds the standardExhaust valve/VentilatorWhen the test sample produces harmful gas, ventilate and exhaust internally.When the pressure in the tank exceeds the pressure of the safety valve and opens the pressure relief valve,the exhaust fan is automatically turned on.AccessoriesMulti-layer vacuum glass observation window,Cable port(50mm),Controlling status indicator lamp,Chamber light,Specimen loading shelf(2pcs,position adjustable),Guaze 5pcs,Operation manual 1 set.Safety protection deviceOver-heat protection circuit breaker,Compressor overload protection,Control system overload protection,Humidifying system overload protection,Overload indicator lamp.Power supplyAC 1Ψ 110V;AC 1Ψ 220V;3Ψ380V 60/50HzCustomized service Welcome to Non-standard,Specail requirements,OEM/ODM orders.The technical information will be subjected to change without noticeOptional accessories
1,Low Humidity and Dehumidifying sytstem.
2,Inner glass door with manual operating ports.
3,Temp./Humi.Recorder.
4,Pure water treatment device
5,RS-485 interface can be linked to Personal computer(PC) and achieve multi-level control & recording software management.
6,Liquid nitrogen(LN2)/Liquid Carbon Dioxide(LCO2) fast cooling-down system.
7,Temperature change rate on average without load(Linear heating up and cooling down);5ºC/min,10ºC/min,15ºC/min,
15ºC/min,20ºC/min,25ºC/min,RAMP function.1. Do you offer after-sales service? How can I ask for that? And how about the warranty?
Every machine from our factory has a 14-month warranty after shipment. Generally, we offer 12 months for the FREE maintenance, while considering of sea transportation, we can extend 2 months for our customers.
If your machine doesn't work, you can send E-mail to us and we will try our best to find the problem by email or skype video chat if neccesary. After confirmation of the problem, we can send you new spare parts or provide on-site repair.
2. What'sthedeliveryterm?
Atmostoftime,wehavestockinthefactory.Ifthereisnostock,normally,thedeliverytimeis15-20workingdaysafterdepositreceipt.Ifyouareinurgentneed,wecanconsidermakinga specialarrangementforyou.