Method of anti mutual- interference and cautions:
Mutual cross installation of optic projector and photo - Receptor.
When using reflection type in parallel, the mutual spacing should be kept at over 1.4 times detection distance.
The mains voltage should be within the range of operating.
The following installation occasions will result in error action, take note of:
1. Dusty occasion
2. The occasion with corrosive gas
3. The occasion directly spattered with water, oil and agent etc
4. Outdoor or the occasion directly shine by hard light like sunlight.TypeFreevoltage,RelaycontactoutputModelRetroreflective(*1)BX5M-MFRDimensionW25*H67*L81DetectingDistance0.1-5mDetectingTargetOpaquematerialsofMin.60mmHysterisis-ResponseTimeMax20mSPowerSupply24TO24VAC+-10%(RippleP-P:Max10%)Sensitivity-OperatingSelectablelightON/DorDarkONbysideswitchControlOutputRelaycontactoutputCapacity:30VDC3AResistiveload,250VAC3AresistiveloadContactorde:1CSelf-diagnosticOutputGreenLEDturnsonatunstableoperationTimerFunctionONdelay,OFFdelay,selectableoneshotdelaybyslideswitchDelaytime:0.1to5secadjustablebyVRProtectionIP54(IECStandard)