Business Type:
Group Corporation
Business Range:
Cable, Power Cable, Electric Wire, ACSR, XLPE Cable
Establishment:
2007
R&D Capacity:
OwnBrand
Terms of Payment:
LC, T/T, PayPal, WesternUnion
Main Markets:
North America, South America, Southeast Asia, Middle East, Africa
OEM/ODM Service
Sample Available

Cable, Power Cable, Xlpe Cable manufacturer / supplier in China, offering Electric/3 Core/XLPE Insulate Power Cable, Low Voltage 25 Sq mm Copper Core PVC Insulated Wire, Solid Copper Core 2.5mm Electrical Cable Price and so on.

1
    YRS
General Supplier

China 0.6 1kv ABC Cable 4*95 mm2

Get Latest Price
Min. Order / Reference FOB Price
1000 Meters US $0.35/ Meters
Local Area: Xinxiang, Henan, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal, WesternUnion
Brand: Jinshui
Type: Insulated
Conductor Type: Stranded
Application: Overhead

0.6/1kV PVC or XLPE or PE Insulated Aerial Cable 4*95 mm 2
(Aerial Bundled Conductor, Service Drop Cable)

1 Description
For single core XLPE insulated or covered aerial cable without messenger or neutral conductor, the phase conductor may be AAC or AAAC or ACSR or Copper.
For more than one core XLPE insulated aerial cable with or without messenger or neutral conductor and with or without street lighting conductor, the phase conductor and street lighting conductor are AAC with XLPE insulation, and the messenger or neutral conductor is AAAC or ACSR with or without XLPE insulation.

2 Operating Characteristics
Rated voltage: 0.6/1kV
Max. permissible continuous operating temperature of conductor with XLPE insulation: 90°C
Max. temperature of conductor during short-circuit (5s max. duration) shall not exceed: 250°C
The ambient temperature under installation should not be lower than: -20°C
The bending radius of cable is recommended as following:
When the diameter of cable is less than 25mm: not less than 4 times of the diameter of cable
When the diameter of cable is not less than 25mm: not less than 6 times of the diameter of cable
When the cable is used in alternative current system, the rated voltage of cable should be at least equal to the rated voltage of system; when the cable is used in direct current system, the rated voltage of system should not greater than 1.5 times of the rated voltage of the cable.

3 Application
XLPE insulated aerial cable as a new-type aerial cable is used for overhead electric power transmission, extensively used in rebuilding of urban and forest region electrified wire netting. It improves the safety and reliance of electrified wire netting.

4 Manufacturing Standards
GB/T 12527-2008, IEC 60502-1, NF C 33-209, BS 7870-5

Technical Characteristics based on Standard NF C 33-209


Designation
Conductor
Average thickness of insulation (XLPE)
Insulated conductor
Conductor type
Nominal area
Number of wires
Max. D.C. resistance at 20oC
Diameter of conductor
Min. breaking load
Overall diameter
Min.
Max.
Min.
Max.
mm2
No.
Ω/km
mm
mm
kN
mm
mm
mm
Phase or neutral non- messenger or street lighting
16
7
1.91
4.6
5.1
1.9
1.2
7.0
7.8
25
7
1.20
5.8
6.3
3.0
1.4
8.6
9.4
35
7
0.868
6.8
7.3
-
1.6
10.0
10.9
50
7
0.641
7.9
8.4
-
1.6
11.1
12.0
70
12
0.443
9.7
10.2
-
1.8
13.3
14.2
95
19
0.320
11.0
12.0
-
1.8
14.6
15.7
120
19
0.253
12.0
13.1
-
1.8
15.6
16.7
150
19
0.206
13.9
15.0
-
1.7
17.3
18.6
Neutral messenger
54.6
7
0.63
9.2
9.6
16.6
1.6
12.3
13.0
70
7
0.50
10.0
10.2
20.5
1.5
12.9
13.6
95
19
0.343
12.2
12.9
27.5
1.6
15.3
16.3