PE/XLPE Insulated ABC Cable, Duplex ABC Cable, Triplex ABC Cable manufacturer / supplier in China, offering ABC Cable with PE/XLPE Insulation (Duplex, Triplex, Quadruplex), Single Core XLPE Insulated Copper Wire Shield 11kv Aluminum Power Cable, Cooper Aluminum Conductor Power XLPE Insulation Cable and so on.

1
    YRS
General Supplier
Supplier Homepage Electrical & Electronics Optical Fiber, Cable & Wire Electric Wire & Cable China 0.6 1kv Aluminiun Core Overhead Line ABC Cable Aluminum Service Drop Triplex Service Drop

China 0.6 1kv Aluminiun Core Overhead Line ABC Cable Aluminum Service Drop Triplex Service Drop

Get Latest Price
Min. Order / Reference FOB Price
1000 Meter US $1000.00/ Meter
Local Area: Luoyang, Henan, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC
Brand: Huatong
Type: Insulated
Conductor Type: Stranded
Application: Overhead, Underground
Aerial Bundled Cable, ABC Cable, Overhead cable,ASTM, BS, NFC, IEC, DIN Standard
Triplex Aluminum Service Drop Cable


Code WordPhase conductorBare Neutral MessengerWeight Per 1000 ft. (lbs.)Allowable Ampacity+Size (AWG)StrandingInsul. Thick. (mils)Size (AWG)Size (kcmil)Strand- ingRated Strength (lbs.)XLPPOLYXLPPOLYAAAC 6201 ALLOY FULL NEUTRAL MESSENGERMinex6145630.58711101011018570Hippa6745630.58711101071078570Prawn4145448.697176015215211590Barnacle4745448.697176016016011590Shrimp2745277.4772800243243150120Gammarus1/07601/0123.374460390390205160Leda1/09601/0123.374460384384205160Dunganese2/07602/0155.475390474474235185Cyclops2/011602/0155.475390474474235185Flustra3/017603/0195.776790587587275215Lepas4/018604/0246.978560728728315245*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.++Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201.



Code WordPhase conductorBare Neutral MessengerWeight Per 1000 ft. (lbs.)Allowable Ampacity+Size (AWG)StrandingInsul. Thick. (mils)Size (AWG)Size (kcmil)Strand- ingRated Strength (lbs.)XLPPOLYXLPPOLYAAAC 6201 ALLOY REDUCED NEUTRAL MESSANGERArtemia4145630.587111013513511590Crab4745630.587111014314311590Solaster2745448.6971760216216150120Sandcrab1/0760277.4772800347347205160Echinus1/0960277.4772800341341205160Crayfish2/07/w60 mls2/0--72510485.8455.3235 Amps185 AmpsSipho2/07/w60 mls2/0--72510485.8455.3235 Amps185 AmpsFulgar3/017601/0123.374460519519275215Arca4/018602/0155.475390643643315245*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.++Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201.




Code WordPhase conductorBare Neutral MessengerWeight Per 1000 ft. (lbs.)Allowable Ampacity+...............Size (AWG)StrandingInsul. Thick. (mils)Size (AWG)Strand- ingRated Strength (lbs.)XLPPOLYXLPPOLYAAC NEUTRAL-MESSENGERHaiotis67/w45 mls67563109.1101.685 Amps70 AmpsPatella6745675631031038570Fusus47/w45 mls47881161.8151.7115 Amps90 AmpsOyster47454788115415411590Clam2745271350233233150120Murex1/07601/071990374374205160Purpura1/09601/071990368368205160Nassa2/07602/072510462462235185Melita3/017603/0193310562562275215Portunus4/018604/0194020696696315245Nannynose336.41980336.419614611181118420325* Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).+ Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.



Code WordPhase conductorBare Neutral MessengerWeight Per 1000 ft. (lbs.)Allowable Ampacity+Size (AWG)StrandingInsul. Thick. (mils)Size (AWG)Strand- ingRated Strength (lbs.)XLPPOLYXLPPOLYASCR NEUTRAL-MESSENGERPaludina614566/111901091098570Voluta674566/111901141148670Whelk414546/11860--16411590Periwinkle474546/1186017217211590Conch27601/06/14380420420205160Neritina1/07601/06/14380420420205160Cenia1/09601/06/14380414414205160Runcina2/07602/06/15310520520235185Triton2/011602/06/15310512512235185Mursia3/017603/06/16620635635275215Zuzara4/018604/06/18350789789315245Limpet336.41980336.418/1868011671167420325*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.



Code WordPhase conductorBare Neutral MessengerWeight Per 1000 ft. (lbs.)Allowable Ampacity+Size (AWG)StrandingInsul. Thick. (mils)Size (AWG)Strand- ingRated Strength (lbs.)XLPPOLYXLPPOLYASCR REDUCED NEUTRAL-MESSENGERScallop414566/11190--14211590Strombus474566/1119015115111590Cockle274546/11190220220150120Janthina1/076026/12853366366205160Ranella1/096026/12853360360205160Cavolinia2/076016/13550453453235185Clio2/0116016/13550444444235185Sanddollar3/019/w60 mls1/06/14380565552275 Amps215 AmpsAega3/017601/06/14380549549275215Cuttlefish4/019/w60 mls2/06/15310699684315 Amps245 AmpsCerapus4/018602/06/15310681681315245Cowery336.41980 mls336/418/1868012091167420 Amps325 Amps*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.


There is a lot of debate still going on as to whether copper is better for electrical purposes or aluminum. If price was not a critical factor, most would suggest going in for silver as it is said to be the best conductor of electricity but has a low strength. However, when it comes to electrical wiring, price is a factor, as is efficiency.
Applications:
To supply power from the utility's lines to the consumer's weatherhead. For service at 600 volts or less (phase to phase) at a conductor temperature of 75°C maximum for polyethylene Insulation or 90°C maximum for crosslinked insulation.
Construction:
Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand AAC, ACSR or 6201 alloy neutral messenger.
Standards:
B-230 Aluminum Wire 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
Triplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA body S-76-474.
There is a lot of debate still going on as to whether copper is better for electrical purposes or aluminum. If price was not a critical factor, most would suggest going in for silver as it is said to be the best conductor of electricity but has a low strength. However, when it comes to electrical wiring, price is a factor, as is efficiency.