Business Type:
Manufacturer/Factory,Trading Company
Business Range:
Industry Air Conditioner, Cleaning Air Conditioner, Water Cooled Chiller, Water Cooled ..
Establishment:
2004
R&D Capacity:
ODM, OEM
Terms of Payment:
LC, T/T
Main Markets:
South America, Europe, Southeast Asia, Middle East, Africa
OEM/ODM Service
Sample Available

Airconditioner R410A, Air Conditioner 40 Ton, 30 Ton Package Unit manufacturer / supplier in China, offering R410 40ton HVAC Air Cooled Rooftop Packaged Air Conditioner, Water-Cooled Screw Water Chiller with Heat Recovery, Water-Cooled Package Unit for Sri Lanka Supermarket and so on.

1
    YRS
General Supplier

China 10 Ton Double Skin Chilled Water Air Handling Unit

Get Latest Price
Min. Order / Reference FOB Price
1 unit US $150000.00/ unit
Local Area: Foshan, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T
Type: Air Handling Unit
Air Tube Material: Galvanized Sheet
Corrosion Durability: Higher
1)The Feature of 10 ton double skin Chilled water ahu ventilation air handling unit
a.frame structure
The latest reinforced aluminum alloy profile is used, with surface being subject to andoic oxidation treatment and internal foamed, to prevent the sweat phenomenon on the frame surface,being firm and beautiful.
b.Box board
It's of sandwich board structure,with foam insulation, of standard thickness 25mm,in which the external material is the second sprayed dhot-dip galvanized sheet steel, of beautiful appearance,resistant to corrosion,rust and weathering;the inner plate is hot-dip galvanized sheet, also resistant to corrosion and rust;the middle rigid polyuredthane foam is uniformly mixed, providing closely integration of external and internal panels and excellent thermal insulation.The box board enjoys firm structure and has excellent performance against sound and vibration.
c.Structure of heat exchange oil
The heat exchange tube are arranged in the triangular staggered manner,generally48 rows;the heat exchanges tubes are made of high-quality copper(TP2).
The High-efficient heat exchanger is made on U.S.OAK assembly line. After overall passing through,the copper tube is closely integrated with the aluminum pieces,providing excellent heat transfer effect,satifsfactory for the occasions of the thermal performance requirements;precision processiong machinery and strict processing control ensure uniform piece distance and tight tube expansion.
The external frame of the coil is bent formed with galvanized stell sheet, being firm and durable;bolt connections are used to prevent rust duce to welding of the galvanized layer.
The design work pressure of the coil is 16 bars,test pressure 25 bars.
e.Fans and motors
Double air-intake centrifugal efficient fans are used, including a volute made of high-quality galvanized steel plate;the side plate enjoys elaborately designed streamlined appearance and machining air intake;the side plate is manufactured with one stamping,enjoying high stiffness,not liable to fatigue dampage;the external part of big fan is a fixed frame structure,enjoying high strngth,stable operation and low vibration;fan impellers are made of high-quality steel plate, of particular streamline shape;each impeller has passed the internal control static/dynamic balance inspection according to national standards.
Fan bearings are from international famous brands,are air-tight ball bearings ,being prior lubricated and aligned,needing no mainTENANCE DURING NORMAL USE PERIOD.
Fan shafts are made of C-45 steel,being subject to rough processing, finishing,secondary quenching and tempering,and will not rust ,easy for repair and maintenance.
Generally low speed fans are used in order to minimize the noise and vibration on the premise that the requirements of air quaitity and pressure are met.
Fan motos are provided by renowed manufacturers,with insulation class B so as to ensure the quality and service life;in addition, the motors of given bradns can be provided when user requires so,or motor insulation class can be enhanced in order to meet the needs of different occasions.
The fans are driven by belts,i.e high-quality V-shaped belits;belt pulleys are precisely machined to ensure concentricity and in accurate matching of the belt;after fans and motors assembly, the second running dynamic balance inspection is carried out in order to achieve the minumum vibration and the highest transmission efficiency.
The bases of fans and notors are all equipped with suitable damper spring shock absorbers;fan outlets and outside box are all flexibly connected using anti-corrosive and moisture-resistant canvas.
f.Coil design
According to varied flows, temperature differences and operating conditions,different internal process designs are adopted in order to maintain coil heat exchange performance and coil water pressure drop at a reasonable and efficient levels and reduce applicaiton difficulty;designed head-on wind speed is 2.5m/s-2.8m/s,and special design requirements are also acceptable
g.Filters
Double nylon embossed nets are used,easy for replacement and removal,can be cleaned and used repeatedly.Non-wovem plate filter can also be fitted at the air intake when required, or a new fresh return air mixing box be used.
Large dust capacity:under the designed final resistance(double the initial resistance)the dust capacity per square meter is more than 100g.
2)Product model

Return Air ConditionItemsDB. Temp.WB. Temp.Inlet Water Temp.Water Temp. DifferenceNominal Cooling Condition27.0ºC19.5ºC7.0ºC5.0ºCNominal Heating Condition21.0ºC 60.0ºC Super-thin Ceiling Mounted UnitModel TypeAir flowNoise LevelCooling CapacityHeating CapacityExternal Static PressureMotor PowerWater FlowWater ResistenceUnit Weight m3/hdB(A)Total HeatSensible HeatKWKWPaKWkg/hkPakgPWB40-4H4000≤5824.6817.2741.81401.142459.525040-6H31.3820.8643.55130539716.526845-4H4500≤5827.9620.8147.331501.1480910.526545-6H35.4222.7649.64140609217.827650-4H5000≤5831.2922.3752.331501.1538212.329250-6H39.1126.2855.74140672719.731055-4H5500≤5933.6725.0856.171501.1579114.730755-6H43.8528.9761.09140754221.432560-4H6000≤6036.3726.1760.682001.5625617.633860-6H47.5331.2864.58190817524.135665-4H6500≤6039.5428.6365.692101.5680019.535565-6H52.7333.8171.65200906927.537170-4H7000≤6043.2630.9672.342201.5744021.835570-6H57.3536.5576.34210966430.937680-4H8000≤6253.3936.7388.072302.2918324.237980-6H68.1043.5991.362201171334.840590-4H9000≤6257.2441.5794.522302984526.741190-6H73.8447.5199.062201270036.4435100-4H10000≤6360.6743.38101.2223031043527.4456100-6H78.7350.92108.332201354137.9495110-4H11000≤6467.0648.38111.8824031153428.8476110-6H86.7756.64119.392301492438.4520120-4H12000≤6572.2852.31120.4529031243229.6490120-6H94.6361.17128.542801627639.7530130-4H13000≤6578.6555.89131.5730041352830.4500130-6H101.4765.47139.762901745241.1554140-4H14000≤6684.4760.90142.3729041452831.0513140-6H109.1970.86150.302801878140.6560150-4H15000≤6692.7364.61156.193105.51595033.5530150-6H118.8578.24161.243002044241.4581160-4H16000≤6698.6869.88167.763005.51697336.7540160-6H128.1081.75170.552902203342.3590

Return Air ConditionItemsDB. Temp.WB. Temp.Inlet Water Temp.Water Temp. DifferenceNominal Cooling Condition27.0ºC19.5ºC7.0ºC5.0ºCNominal Heating Condition21.0ºC 60.0ºC Ceiling Mounted UnitModel TypeAir FlowNoise LevelCooling CapacityHeating CapacityExternal Static PressureMotor PowerWater FlowWater ResistenceUnit Weight Model TypedB(A)Total HeatSensible HeatKWKWPaKWkg/hkPakgPWD15-4H1500≤529.626.7516.061100.5516554.412515-6H12.728.9021.2110021875.613020-4H2000≤5212.658.8320.931100.5521765.215020-6H16.0210.3821.9510027557.215825-4H2500≤5315.7210.9826.051200.5527035.917025-6H19.8612.6427.2611034168.018030-4H3000≤5619.0813.3832.271400.7532816.719530-6H24.0315.3833.69130413310.421035-4H3500≤5621.3115.4336.821600.7536657.823535-6H27.0317.9538.67150464913.025040-4H4000≤5824.6817.2741.801601.142459.525440-6H31.3820.8643.55150539716.527045-4H4500≤5827.9820.8147.332101.1480910.526845-6H35.4222.7649.64200609217.828050-4H5000≤5831.2922.3752.332101.153829.129550-6H39.1126.2855.74200672715.731255-4H5500≤5933.6725.0856.172201.157919.831055-6H43.8528.9761.09210754217.332760-4H6000≤6036.3726.1760.682301.5625610.934160-6H47.5331.2864.58220817519.226065-4H6500≤6039.5428.6365.962301.5680011.735865-6H52.7333.8171.65220906921.037570-4H7000≤6043.2630.9672.172701.5744012.936070-6H57.3536.5576.34230966423.238080-4H8000≤6253.3936.7388.072502.2918314.338280-6H68.1043.5991.362401171325.940890-4H9000≤6257.2441.4794.522802.2984522.641590-6H73.8447.5199.062701270020.5440100-4H10000≤6360.6743.36101.2228031043512.8460100-6H78.7350.92108.332701354122.9500110-4H11000≤6467.0648.38111.8831031153513.8480110-6H86.7756.64119.393001492424.9524120-4H12000≤6572.2852.31120.4529031243214.4495120-6H94.6361.17128.542801627625.8535130-4H13000≤6578.6555.89131.5730041352819.6510130-6H101.4765.47139.762901745227.3558140-4H14000≤6684.4760.90142.3730041452826.3520140-6H109.1970.86150.302901878120.9570150-4H15000≤6692.7364.61156.193105.51595028.7535150-6H118.8578.24161.243002044222.1589160-4H16000≤6698.6869.88167.763105.51697330.8546160-6H128.1084.75170.553002203324.5600

Return Air ConditionItemsDB. Temp.WB. Temp.Inlet Water Temp.Water Temp. DifferenceNominal Cooling Condition27.0ºC19.5ºC7.0ºC5.0ºCNominal Heating Condition21.0ºC 60.0ºC floor standing unitModel TypeAir FlowNoise LevelCooling CapacityHeating CapacityExternal Static PressureMotor PowerWater FlowWater ResistenceUnit Weight Model TypedB(A)Total HeatSensible HeatKWKWPaKWkg/hkPakgPWL40-4H4000≤5824.6817.2741.801701.142456.725640-6H31.3820.8643.55160539710.327645-4H4500≤5827.9620.8147.332001.148097.627545-6H35.4222.7649.64190609212.128650-4H5000≤5831.2922.3752.332001.152828.530250-6H39.1126.2855.74190672713.931955-4H5500≤5933.6725.0856.172101.157919.531855-6H43.8528.9761.09200754215.733560-4H6000≤6036.3726.1760.682301.5625610.635060-6H47.5331.2864.58220817517.837065-4H6500≤6039.5428.6365.692301.5680011.737165-6H52.7333.8171.65220906919.538770-4H7000≤6043.2630.9672.173001.5744012.537270-6H57.3536.5576.34290966421.339380-4H8000≤6053.3936.7388.073002.2918313.439480-6H68.1043.5991.362901171323.942090-4H9000≤6257.2441.4794.523102.2984514.442790-6H73.8447.5199.063001270025.7455100-4H10000≤6360.6743.36101.2231031043527.4476100-6H78.7350.92108.333001354116.4517110-4H11000≤6467.0648.38111.8831031154316.5498110-6H86.7756.64119.393001492430.8540120-4H12000≤6573.3953.04122.4435031262317.3510120-6H94.2862.31129.703401621631.3554130-4H13000≤6578.6555.89131.5735041352817.6518130-6H101.4765.47139.763401745232.4564140-4H14000≤6684.4760.90142.3736041452818.1535140-6H109.1970.86150.303501878133.8586150-4H15000≤6692.7364.61156.193605.51595018.8546150-6H118.8578.24161.243602044235.2601160-4H16000≤6698.6869.88167.763505.51697319.4560160-6H128.1081.75170.553602203336.7620180-4H18000≤66119.5882.03194.493505.52056726.5603180-6H154.4496.92212.513402656440.8662200-4H20000≤67130.5089.63215.723605.52244631.3652200-6H170.95108.08234.633502940347.5715

Return Air ConditionItemsDB. Temp.WB. Temp.Inlet Water Temp.Water Temp. DifferenceNominal Cooling Condition27.0ºC19.5ºC7.0ºC5.0ºCNominal Heating Condition21.0ºC 60.0ºC floor standing unitModel TypeAir FlowNoise LevelCooling CapacityHeating CapacityExternal Static PressureMotor PowerWater FlowWater ResistenceUnit Weight Model TypedB(A)Total HeatSensible HeatKWKWPaKWkg/hkPakgPWL220-4H22000≤68142.3599.49230.453605.52448416.5803220-6H183.47116.78264.013503155730.8887250-4H25000≤69160.87111.57268.393507.52767017.3854250-6H206.48130.31284.153403551431.3945280-4H28000≤70176.22123.21293.673507.53031017.9935280-6H227.34143.62311.543403910232.01050300-4H30000≤71190.13130.29317.213507.53270318.41025300-6H245.36158.73336.723404220132.81130350-4H35000≤73218.01154.43363.384505.5x23749718.11080350-6H298.38185.60385.314405132133.41250400-4H40000≤74250.35178.52421.544605.5x24306031.31183400-6H347.66220.75446.174505979847.51340450-4H45000≤74286.37200.83473.564807.5x24925527.41270450-6H383.482422.67497.234706595942.51490500-4H50000≤74320.48224.33528.445007.5x25512224.31410500-6H418.61263.72551.57490720013761620600-4H60000≤75382.56266.79603.7556011x26580027.71650600-6H466.28293.76638.865508020039.41845

3) Display:
4)Packing
5)Our company file
5)Company Culture:
Serve the society with technology, serve the customer with heart, become a first level air conditioning company in China.
Innovation, loyalty, responsibility, value.
Provide customer with high quality product and considerable service.
6)Our services:
1) Changing on material, color, shape, construction:Acceptable.
2) General inspection on fixing before packing
4) We can offer you premium quality , competitive price, prompt delivery and low minimum orders.
5) OEM,ODM service.
7)Project and client:


No
Project Name ( China)
Industry
Area
1
Zhongshan people hospital
Hospital
Zhongshan
2
Hankou Railway Station, Union Hospital, Wuhan Branch
Hospital
Wuhan
3
Wuhan City, Wuchang Railway Hospital
Hospital
Wuhan
4
Three townships Zhongshan People's Hospital
Hospital
Zhongshan
5
Zhujiang hospital of Guangzhou
Hospital
Guangzhou
6
Zhongshan Garden Hotel
Hotelindustry
Zhongshan
7
Western Sunshine Hotel, Zhongshan
Hotelindustry
Zhongshan
8
Shunde Golden Hotel
Hotelindustry
Foshan
9
East China Hotel in Guangzhou
Hotelindustry
Guangzhou
10
Nanyou Zhuhai hotel
Hotelindustry
Zhuhai


No
Company Name ( Overseas)
Product
Country
1
SB Global Energy
Air cooled ducted split
Holland
2
Bentos pharmaceutical products Ltd.
Clean air conditioners
Nigeria
3
SOGAMEF
Air cooled chiller
Gabon
4
SeaService shipping
Marine air conditioner
Russia
5
EURO STANDARD LIMITED
Fresh Air Handling Unit
New Zealand
6
Henrich trading center
Air cooled/water cooled air conditioner
Philippines
7
Marine Engineering Systems Pte.Ltd
AHU, chiller,etc
Singapore
8
Elektro Werner Heitzinger
Heat recovery air handling unit
Austria
9
Nyborg Marine Equipments AS
Marine Air Handling Units
Norway
10
Wilfred Limited
Heat recovery air handling unit
UK


Contact Way:
Carrie Mak
GuangDong Head-Power Air Conditioning Co.,Ltd.
Add: Shiling Chenbian Section, 321 National Highway, Shishan Town,
Nanhai District, Foshan,Guangdong,China.
Mobile:86-15024293999
Tel: 86-757-88364517,18 Fax:86-757-86688063

http://headpower2.en.made-in-china.com