Business Type:
Trading Company
Business Range:
Composite Autoclave, Glass Autoclave, Autoclave, Laminated Autoclave, Glass Laminated ..
Establishment:
2012
R&D Capacity:
ODM, OEM, Other
Terms of Payment:
LC, T/T
Main Markets:
Europe, Africa, Australia, Domestic
OEM/ODM Service
Sample Available

Composite Vessel, Vessel for Carbon Fiber, Industrial Pressure Vessel manufacturer / supplier in China, offering 3000x6000mm Composite Oven Manufacturer in Aerospace Field, 1000x1500mm Horizontal Skid-Mounted Carbon Fiber Curing Autoclave for Laboratory Use, Sinomac Laminating Glass Autoclave with ASME Certificate and so on.

1
    YRS
General Supplier
Supplier Homepage Manufacturing & Processing Machinery Chemical Equipment & Machinery Pressure Vessel China 1000x1500mm CE PED Approved Composite Autoclave for Resin Matrix

China 1000x1500mm CE PED Approved Composite Autoclave for Resin Matrix

Get Latest Price
Min. Order / Reference FOB Price
1 Set US $30000.00/ Set
Local Area: Jian, Jiangxi, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T
Function: Heat Pressure Vessel, Reaction Pressure Vessel
Application: Composite Curing
Material: Carbon Steel

The composite autoclave is a key equipment for hot-pressing shaping of carbon fibers and resin matrix composites. The quality of the product is obtained inside the autoclave reaching an increase of mechanical features up to 20-30% compared to other methods of polymerization. The reliability and the precision of the cycles which can be obtained with our autoclaves, allowing to reach and keep high quality standards of the product, which is widely used in the high-tech fields such as aerospace, automobile, electronics, weapon, traffic, sports equipment and new type of energy, etc.

composite autoclave is equipped with advanced Thermal Processing Control (TPC) system. TPC is a PC-based control solution designed specifically for composite curing in autoclaves. It is developed on the basis of the advanced control systems that come from excellent domestic and overseas manufacturers. It is preferred control system for the most customers. The system has the login of user permissions, parts sensor selection, curing process curve setting, calling, saving and printing, automatic and manual operation, real-time data monitoring, recording, storage and printing, system status monitoring, event alarm, quality analysis,etc.

3.1 General Feature
Autoclave is a sealed pressure vessel which can be heated by a forced convection heating unit, where temperature, pressure and vacuum can be controlled effectively. By means of an advanced design, consisting of a forced convection fun and motor unit, output heating power system can be adjusted 0-100%,proportional control of the pressurization, cooling and exhaust components. It can obtain an uniform temperature and pressure according to the process curve. Temperature is check in heating, keeping, and cooling phase. The heating/cooling gradients can be set by operator. Pressure is adjusted in pressurization, keeping, release phase.
3.2 Working Process
The whole working process of Autoclave has 15 segments .In each segment, the value of temperature, pressure, vacuum and segment time can be set and monitored by HIM and PC, and the operation process will be realized by our exclusively developed software which is based on PLC control system to ensure the full automatic operation. SINOMAC Autoclave is suitable for manufacturing various composite materials, and it also can guarantee the perfect product quality.
3.2.1 Example recipe

Vacu1: minimum vacuum pressure Vac2: maximum vacuum pressure
Press.1: pre-pressurePress.2: final pressure
Temp1:temperature of first segmentTemp2: temperature of second segment
Temp3: temperature of third segment Temp4: temperature of forth segment
Temp5: temperature of cooling and release
T1: keeping time of first segment T2 : keeping time of second segment
T3: keeping time of third segmentT4 :keeping time of forth segment

3.2.2 SINOMAC Control System Structure

4.1 Manufacture Standard
Pressure vessel with quick-opening door, can be certified to:
4.2 Pressure Vessel Certification and Compliance
The autoclave is 100% GUARANTEED to meet and exceed the local and national government regulations. As such, documentation will be provided as follows - but not limited to - by the Seller to ensure the autoclave is fit for professionally use:Pressure Vessel Certificate,SILO (LOCAL) approval and certification,Calculation Sheet - Proof of the manufacturers calculations,NDT Inspection Certificate,Certificate of Set Pressure - relief value testing.Welding record certificate,Hydrostatic testing report,Certificate of Quality.4.3 Operation Specifications
4.3.1Operational Standards & Requirements
The autoclave is 100% GUARANTEED to meet and exceed the operational requirements set-out in the following commercial industry documents: D6-49327: Boeing standard for Qualification of Autoclaves for metal Bonding and Curing Composite Structure. Release F, December 15, 2010BAC5621: Boeing standard for "Temperature Control for Processing Materials".4.3.2 PressurePressurization Medium: Compressed Air or Nitrogen.Maximum working pressure: 1.0 MPa (12 bar).Maximum design pressure: 1.2 MPa (12 bar).Pressurization rate: 0-0.6 bar/min average rate from 0 bar to max. working pressure.De-pressurization rate:0-0.6 bar/min average rates from max. working pressure to 0 bar.4.3.3 Temperature Maximum working temperature: 220 °C.Maximum design temperature of vessel: 200 °C.Heating rate:0-5 °C/min based on average air temperature from current temperature to 200 °C for 30kgs carbon fiber material and 30 kgs tool steelCooling rate:0-5 °C/min based on average air temperature from 200 °C to 50 °C for 30kgs carbon fiber material 30 kgs tool steel4.4.4 VacuumLimit vacuum: ≤ -0.098 MPaMaximum working vacuum: -0.08 MPa.


5.1 No air duct
Conventional autoclaves have an annular duct that is used to transfer air from the rear of the autoclave to the front. This air duct requires a larger pressure vessel and increase some extra ducting sheet metal .These factors will cause the high energy consumption on heating and cooling, increasing the use cost of customer's. SINOMAC composite autoclave does not require an annular air-duct and instead utilizes the floor as the forward air delivery system. It has a Sieve-Ventilation slots system in the rear and front of the autoclave. This unique design feature reduces the pressure vessel diameter by 100-150mm when compared to a conventional autoclave. This reduction in size and the elimination of the inner air duct reduces operating heating costs, pressurization costs, and equipment price.
5.2 Unique heating and cooling systems under the floor
In conventional autoclaves, the heater and cooling exchanger typically mounted at the rear of the autoclave. This rear-mounted approach requires the autoclave pressure vessel to be up to 1.5m longer to accommodate the components and the transition ducting at least.SINOMAC composite autoclave on the other hand incorporates floor-mounted heaters and cooling exchangers and therefore eliminates the need for the additional vessel length. This feature allows the SINOMAC autoclave's vessel to be much shorter than the vessel used for a conventional autoclave. This positively impacts operational costs by reducing the amount of heating required and the amount of pressurization gas used for a standard cycle.
5.3 Advantage of Sieve-Ventilation slots system
SINOMAC composite autoclave utilizes Sieve-Ventilation slot panels to straighten and balance air flow in the autoclave.
Sieve-Ventilation slots are full-area, flow adjusting panels that facilitate the balancing and straightening of the air flow at the front and rear of the autoclave prior to entering/exiting the working volume. Unlike conventional autoclaves, an composite autoclave with Sieve-Ventilation slot technology has no dead-spots and therefore provide near 100% useable volume for your parts. The overall result is unequalled temperature uniformity down the entire length of the autoclave and uniform heating and cooling of your valuable part load.
5.4 Advanced structure of door sealing ring
Using ceramic fiber channel segregation, and a special cooling system.
5.5 Fully sealed circular motor fan
Fully sealed special motor, bearings with SKF high-temperature series. The structure is easy to maintenance and, no oil leakage, no air leakage.


MODEL# SN-CGF1015 COMPOSITE AUTOCLAVE_TECHNICAL PARAMETERNo.DescriptionUnitSpecifications and Parameters1Effective Working Diametermm10002Effective Working Lengthmm15003Autoclave Track DistancemmNo track4Track Height (from floor to track plane)mmNo track5Design PressureMpa1.26Max. Working PressureMpa1.057Max. Pressurization Rate (average)bar/min0.68Max. Depressurization Rate (average)bar/min0.69Safety Valve ExhaustMpa1.1510Design TemperatureºC22011Max. Working TemperatureºC20012Max. Heating Rate(Air average)ºC/min313Max. Cooling Rate (Air average)ºC/min314Thermal Load during TestKg20KG steel15Temperature Uniformity at Steady StateºC±216External Shell Temperature at max. TemperatureºC<6017Quick Openning Door Mode---Hydraulic18Working Medium---Compressed air19Heating Mode---Electric (Convection+Radiation)20Heater---Inconel tubular heaters21Heating PowerKW5022Quantity of Circulating Fan MotorSet123Power of Circulating Fan MotorKW7.524Thermocouple Type---Type K or J 25Air Temperature ThermocouplesPiece126Part Temperature ThermocouplesPiece427Quantity of Pressure TransducerPiece128Vaccum LinesPiece229Quantity of Vacuum ProbePiece230PLC-controlled Valves on each Vacuum Line---Vacuum and Vent31Min. Vacuum PressureMpa-0.0832Standard Control Mode---PLC+PC33Control Software---Thermal Processing Control (TPC)34Insulation Type---Internal35Insulation MaterialmmCeramic fiber36Insulation Thickness---8037Insulation Sheet metalºCStainless Steel or Aluminized Steel38Working Environment Temperature---Min. -20ºC, max. +45ºC39Working Environment Humidity---<60%40Power Supply---220/380VAC, 3P+N+PE, 50/60Hz41WeightKg5240