Slurry Pumps, G12110 A05, Volute Liner manufacturer / supplier in China, offering 14/12 St-Ah Slurry Pump Volute Liner (G12110 A05), Electric Slurry Mud Sludge Trash Pump (2PN /3 PN /4 PN), Carbon Steel / Stainless Steel Discharge Flange Pipe for Pump and so on.
Min. Order / Reference FOB Price | |
---|---|
1 Piece | US $39000.00/ Piece |
Local Area: | Huaan, Jiangsu, China |
---|---|
R&D Capacity: | OEM, ODM, Other |
Payment Terms: | LC, T/T, PayPal |
Max.Head: | 80-110m |
---|---|
Max.Capacity: | >400 L/min |
Driving Type: | Motor |
16/14 TU-AH Mineral Flotation Processing Pumps
TypeAllowable Mating Max. Power(Kw) Clear Water PerformanceImpellerMaterialCapacity/Q m³/hrHead/m peed
rpmMax Eff%NPSH/mNos of VaneImpeller Diameter/
mm1.5/1-NAH15M12.6--28.86--681200--3800402--45152R10.8-25.27-521400-34003532X1.5-NAH15M32.4--726--581200--3200453.5--85184R25.2-545.5-411000-2600502.5-51783X2-NAH30M39.6--86.412--641300--2700554--65214R36-75.613-391300-2100552-42134X3-NAH30M86.4--1989--521000--2200714--65245R79.2-1805-34.5800-1800593-56X4-NAH60M162--36012--56800--1550655--85365R144-32412-45800-1350653-58X6-NAH 300M360--82810--61500--1140722--95510R324-7207-49400-1000655-1010X8-NAH 560M612--136811--61400--850714--105686R540-118812-50400-750754-1212X10-NAH560M936--19807--68300--8008265762R720-16207-45300-650802.5-7.514X12-NAH560M1260--277213--63300--600773--105965R1152-252013-44300-500793-816X14-NAH1200M1368--306011--63250--550794--105106720x18-NAH1200M2520--540013--57200--400855--105 1370
AH seriesL(R), MHHSP(R)GAF Series1.5/1B-AH(R)20A-L1.5/1 C-HH40PV-SP(R)6/4D-G2QV-AF2/1.5B-AH(R)50B-L(R)3/2D-HH65QV-SP(R)8/6E-G3QV-AF3/2C-AH(R)75C-L4/3E-HH100RV-SP(R)10/8F-G6SV-AF4/3C-AH(R)100 D-L4/3X-HH150SV-SP(R)10/8S-G8SV-AF6/4D-AH(R)150E-L6/4F-HH200SV-SP12/10G-G 6/4E-AH(R)300S-L6/4X-HH250TV-SP14/12G-G 8/6E-AH(R)10/8 R-M6S-H 14/12T-G 8/6R-AH(R)10/8 E-M8/6S-H 16/14 G-G 10/8F-AH(R) 8/6X-H 16/14TU-GH 10/8X-AH(R) 6S-HP 16/14H-GH 12/10ST-AH(R) 8/6S-HP 18/16G-G 14/12ST-AH(R) 8/6X-HP 18/16 TU-GH 16/14TU-AH(R) 20/18G(TU)-AH(R)
Faults Reason Settlement1.Pump fails to discharge any water,The hand of pressure gauge beat violently 1.Suction pipe don't have enough water.
2.Suction pipe blocked or the valve is locked.1. Inject enough water
2.unlock the inlet valve,clear the blocks
3.Exclude the air leakage 2.The pump can't discharge water,the hand of vacuum meter beat heavily. 1.The inlet valve is unlocked or silted up.
2.The resistance of suction pipe is too big or silted up.
3.The height of suction is too high. 1.Unlock the valve or desilting
2.improve the design of suction pipe or desilt
3.Lower the height of the installation.3.The pump can't discharge water,pressure gauge shows heavy pressure.1.The resistance of the discharge pipe is too big.
2.The impeller blocked
3.The speed is slow.1.Check and adjust the outlet pipe.
2.Clear the impeller
3. Improve the speed.4.The pump doesn't rotate The volute is silted up by the blocks. Clear the blocks5.The capacity is not enough 1.The blocks of the impeller or the inlet or outlet pipe.
2.The abrasion of the impeller is heavily.
3.The speed is low to normal
4.Pump is installed unreasonably or the leakage of the inlet pipe.
5.The transporting height is too high,the loss of the resistance of the inside pipe are too big.
6.The inlet valve not open enough or blocked
7.The packing seal leaks1.Clear the impeller or pipe.
2.Change the impeller
3.Adjust the speed
4.Install again or stop leaking.
Decrease the height of the transport or reduce the resistance.Unlock the inlet valve Compress the packing tightly6.The motor of the pump is overloaded 1.The head of the pump exceeds the head of the working condition.
2.Not consider the slurry density when selecting the pump.
3.The packing press tightly1.Turn down the outlet valve,cut the impeller or lower the speed.
2.Select the motor again.
3.Adjust the the screw of the packing gland 7.Abnormal sound in the pump, and no water out1.The resistance of the inlet pipe is too big.
2.The height of the suction is too high.
3.Cavitation occurred there is air in the inletThe temperature of the liquid is too highClear the suction pipe and sluice valve.Lower the height of the suction Adjust the water valve and let the pump operate in the defined limits.Block the leakage.Lowering the liquid temperature.8.pump vibrates1.pump cavitate
2.The block of the impeller single vane
3.The no concentricity between the pump shaft and motor shaft
4.Fasteners or foundation loose1.Adjust the water valve ,lower the height of the installation,reduce the resistance of the inlet.
2.Clear the impeller
3.Alignment again
4.Fasten the screw,and reinforce the foundation.9.Bearing is overheat 1.lock the cooling water
2.lubrication is not good.
3.the lubrication oil is not clear
4.the wrong direction of the thrust bearing.
5.there is something wrong with the bearing.Open the cooling waterAdjust the oil quantity Clear the shaft,change oilAccording to the inlet pressure,adjust the direction of the thrust bearing.Change the bearing 10.Packing short life The material of packing is not good Change the packing 11.pump leak oil1.High oil level
2.The rubber parts invalid
3.Assembly problem1.Lower the oil level
2.Change rubber spares
3.Adjust the assembly
12 Pump head leaking 1.The rubber parts not press wellAssembly again or press tightly