Supplier Homepage Electrical & Electronics Variable-Frequency Drive China 1kw Frequency Converter for Electric Motor 60Hz 50Hz

China 1kw Frequency Converter for Electric Motor 60Hz 50Hz

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $500.00/ Piece
Local Area: Wenzhou, Zhejiang, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, PayPal, WesternUnion, Small-amountpayment
Brand: Kayal
Application: High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, Hi
Output Type: Triple
Principle of Work: V/F Control Transducer

Do not install this equipment in an explosive gas atmosphere, or there will be explosion hazards.
only qualified individuals should proceed with wiring, or there will be electric shock hazards. Do not conduct any wiring during the system power on to avoid the electric shock..
Do not touch control terminals, internal circuit board and its components, or there will be electric shock hazard.
Earth terminal must be exactly grounded when using inverter. Grounding must be confirmed with the national electric safety regulation and other electric code.
After power off, do not touch internal circuit board or any parts inside within 5 minutes after keypad display went off. Any internal operation must be after making sure of discharge off with instrument checking to avoid the electric shock.
Do not connect AC power to output terminal (U, V, W) of inverter. The only terminal the AC power allowed to be connected is R, S, T (or L1, L2 single--phrase source inverter).
Static electricity on human body can damage MOS device. Do not touch PCB and IGBT without anti-static measure.
Do not lose screws, spacers and other metallic foreign bodies inside the driver to avoid fire hazard and driver damage.
Do not connect 220V AC power to internal control terminal of the driver, or there will be serious damage to the driver.
If overcurrent protection occurs after start the driver, confirm again the external wiring and then power on and run the driver.
Do not switch off the power to stop the driver. Cut off power source after the motor stops running.
Do not install the driver in places with direct sunlight.

Voltage ClassesRated Power(KW) Rated Output Current Adapted Motor(A) (KW) 220V 1-phase0.754.50.751.571.52.2102.2380V 3-phase0.752.50.751.53.71.52.252.2

Input

Rated voltage,

frequency

Three-phase 380V; 50/60Hz

Voltage

allowable

range

OutputVoltage"Three phase; 0-460V
Single phase; 0-260V"frequency

Low frequency mode: 0-300Hz

High frequency mode: 0-3000Hz

Overload

capability

"G type machine:

110% long-term 150% 1 minute 180% 5 seconds
P-type machine:

105% long-term 120% 1 minute 150% 1 second"

control ability

V/F control, advanced V/F separation control,

current vector control

Control

characteristics

Frequency

setting

resolution

Analog input

0.1% of the

maximum output frequency

Digital setting0.01Hz

Frequency

accuracy

Analog input

Within 0.2% of the

maximum output frequency

Digital input

Set within 0.01% of the

output frequency

V/F control

The reference frequency can be arbitrarily set at 5-600Hz,

and the multi-point V/F curve can be set arbitrarily.

Various fixed curves such as constant torque,

low reduction torque 1,

low reduction torque 2,

and square torque can also be selected.

Manual setting: 0.0-30.0% of rated output
Automatic lifting:

automatically determine the lifting counter according

to the output current and combined with the motor parameters

Automatically detects motor stator current

and voltage during acceleration,

deceleration or stable operation.

A unique algorithm minimizes the possibility

of system fault trips within the allowable range.

Control

characteristics

Non-inductive

vector control

Voltage frequency characteristics

Automatically adjust the output

voltage-to-frequency ratio

based on motor parameters

and unique algorithms

Torque characteristic

Starting torque:
050% rated torque at 3.0 Hz

(VF control)
180% rated torque at 0.5 Hz

(no PG current vector control,

flux vector control)
180% rated torque at 0.05Hz

(with PG current vector control)
Steady-state accuracy of running speed:

≤±0.2% rated synchronous speed
Speed fluctuation:

≤±0.5% rated synchronous speed
Torque response:

≤50ms PG vector control,

no PG vector control,

flux vector control ≤20ms

Motor parameter self-determination

Without any restrictions,

the automatic detection of parameters

can be completed under

static and dynamic motor,

and the best control effect is obtained.

Current and voltage suppression

Full-time current closed-loop control, complete avoidance

of current surge,

complete overcurrent

and overvoltage suppression

Undervoltage

suppression

during

operation

Especially for users with low grid voltage and

frequent grid voltage fluctuations,

the system can maintain the longest possible

running time according to a unique algorithm and

disability allocation strategy even below the allowable

voltage range.

Typical

function

Multi-speed

and swing

frequency

operation

16-segment programmable multi-speed control and multiple operating modes are available.

Swing frequency operation: preset frequency, center frequency adjustable,

state memory and recovery after power failure

PID control

RS485

communication

Built-in PID controller (preset frequency).

Standard configuration RS485 communication function,

multiple communication protocols are optional,

with linkage synchronous control air energy function

Frequency

setting

Analog input

DC voltage 0-10V, DC current 0-20A

(upper and lower limits are optional)

Digital input

Control panel setting,

RS485 interface setting,

UP/DW terminal control,

can also be combined with analog input

output signalDigital output

2 OC outputs and one fault relay output

(TA, TB, TC),

up to 16 meaning choices

Analog output

2 channels of analog signal output,

the output range is flexible

between 0-20mA or 0-10V,

which can realize the output of physical

quantity such as set frequency and

output frequency.

Automatic

voltage

regulation

operation

According to the needs of dynamic voltage regulation,

static voltage regulation,

and non-voltage regulation,

the most stable operation results have been obtained.

Add and

deceleration

time setting

0.1s-3600min continuous setting, S type, linear mode optionalbrakeEnergy brake

Energy consumption braking

starting voltage,

hysteresis voltage and energy

consumption braking rate

are continuously adjustable

DC braking

Shutdown DC braking start frequency:

0.00-{F0.16} on-line frequency
Braking time:

0.0-100.0S;

braking current:

0.0%-150.0% rated current

Typical

function

brakeFlux braking0-100 0;invalid

Low noise

operation

Carrier frequency 1.0KHz-16.0KHz continuously

adjustable to minimize motor noise

Speed

maximum

speed

restart

function

Smooth restart and instantaneous stop restart in time transfercounterOne internal counter for easy system integration

Running

function

Upper and lower limit frequency setting,

frequency jump operation,

reverse operation lower limit,

slip frequency compensation,

RS485 communication,

frequency increment 'decreasing control,

fault self-recovery operation, etc.

display

Control

operation

surface

Operating status

Output frequency, output current,

output voltage, motor speed,

set frequency, module temperature,

PID setting, feedback amount,

analog input and output

Alarm content

The last six fault records,

the output frequency,

the set frequency,

the output current,

the output voltage,

the DC voltage,

the module temperature,

etc.

Protective function

Overcurrent, overvoltage,

undervoltage, module failure,

electronic thermal relay, overheating,

short circuit, input and output phase,

motor parameter tuning abnormality,

internal memory failure, etc.

surroundings

Ambient

temperature

-10°C-+40°C

(the ambient temperature is between 40°C and 50°C, please derate)

Ambient

humidity

5%-95% RH,

anhydrous beads condensation

surroundings

Indoor

(no direct sunlight,

no corrosion,

flammable gas,

no oil mist,

dust, etc.)

altitude

Derating for use above 1000 meters,

derating 10% for each 1000 meters increase

structure

Protection

level

IP20

cooling

method

Air cooled,

with fan control

Installation method

Wall-mounted,

cabinet