Business Type:
Manufacturer/Factory
Establishment:
2012
R&D Capacity:
ODM, OEM, Other
OEM/ODM Service
Sample Available

ISO Tank, ISO Tank Container, Tank Container manufacturer / supplier in China, offering Anhydrous Liquid Ammonia Isotank Nh3 ISO Tank Container 20FT 24000L, 3 Axkes Liquid Ammonia Tank Trailer Pressure 2.49MPa Tank Volume 46000liters, Loading 23920K (NH3 Anhydrous Liquid Ammonia Gas), T20 Tank (UNPortable Tank) Un1838 - Cl4ti Titanium Tetrachloride 3220liters and so on.

1
    YRS
General Supplier

China 2.29MPa Pressure Vessel 200cbm Liquid Ammonia Storage Tank V 200m3

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $40000.00/ Piece
Local Area: Wuhan, Hubei, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Condition: New
Customized: Customized
Tank Marerial: Metal Tank

200CBM Liquid Ammonia Storage Tank V 200m3 Working Pressure Vessel 2.29MPa
Liquid Ammonia Storage Tank 10cbm-200cbm Anhydrous Liquid Ammonia (Liquid NH3 Pressure Vessel )
Detail Picture
2.29MPa Pressure Vessel 200CBM Liquid Ammonia Storage Tank V 200m3




Butane Tank Horizontal Storage 40m3 (Pressure Vessel ) for LPG Gas Propane, Liquid Sulfur Dioxide,Isobutane, Dimethyl Ether

Propane design pressure of 1.77 MPa design temperature 50 ºC corrosion allowance 1 mm density of 0.42 T/M3
Design of liquid ammonia pressure of 2.16 MPa design temperature 50 ºC corrosion allowance 2 mm density of 0.52 T/M3
Propane design pressure of 1.77 MPa design temperature 50 ºC corrosion allowance 1 mm density of 0.42 T/M3
Propane design pressure of 2.16 MPa design temperature 50 ºC corrosion allowance 1 mm density of 0.43 T/M3
Liquid sulfur dioxide design pressure of 0.98 MPa design temperature 50 ºC corrosion allowance 4 mm density of 1.2 T/M3
Gas pressure is 4.1 MPa design temperature 50 ºC corrosion allowance of 1.4 mm
Propane design pressure of 1.77 MPa design temperature 50 ºC corrosion allowance 1 mm density of 0.42 T/M3
Isobutane design pressure of 0.79 MPa design temperature 50 ºC corrosion allowance 1 mm density of 0.49 T/M3
Dimethyl ether design pressure of 1.15 MPa design temperature 50 ºC corrosion allowance 1 mm density of 0.58 T/M3
Liquid ammonia is a basic chemical raw material, widely used in metallurgy, textile, papermaking and other industries, and is a raw material for the synthesis of hydrochloric acid, polyvinyl chloride, plastics, and pesticides. Liquid ammonia is a yellow-green oily liquid, highly hazardous (Liquid ammonia toxicity is classified as Class II in GBZ230), strong oxidants, and Liquid ammonia gas are not explosive but can support combustion (classified as B in GB50016).
Liquid ammonia storage tanks mostly use horizontal storage. The materials of storage tanks are generally low alloy plates specially used for low alloy pressure vessels such as Q345R and 16MnDR. The design pressure is 60 ° C, which is the saturated vapor pressure of Liquid ammonia gas, and the volume is generally 25 ~ 100m3. The loading factor is ≤ 0.8. For Liquid ammonia, consider setting up a storage tank with the largest volume as the accident tank. once the storage tank leaks, most of the Liquid ammonia can be poured into the accident tank. The equipment is provided with pressure, liquid level and temperature detection. At the same time, the signal should be concentrated to the DCS system. The pressure and liquid level detection should be provided with a root shut-off valveThe inlet and outlet of the storage tank shall adopt double valves. At the same time, the inlet and outlet of the storage tank shall be provided with an emergency shut-off valve, the storage tank shall be provided with a safety valve, and the safety valve shall be provided with a root shut-off valve. A sewage pipeline is set at the bottom of the Liquid ammonia storage tank, and the drainage cycle is determined according to the concentration of nitrogen trichloride in the Liquid ammonia. The Liquid ammonia drainage needs to be processed by an alkali absorption tank. If the tank farm reserves more than 5 tons, it will constitute a key hazard source, and the safety protection distance between the tank farm and the surrounding facilities shall meet the requirements of project establishment evaluation.
Parameter table of liquid ammonia storage tankNoName Design pressure / temperatureCapacity
(m3)Body specifications / head wall thickness(mm)Material Net Weight
(Kg)Total Length
(mm)Level gauge center distance(mm)Note1Liquid ammonia storage tank DN1400 V=5m32.16/-20/545DN1400x2750x12/12Q345R246535471600Setting pressure of safety valve is 2.23MPa, the maximum allowable working pressure is 2.34MPa2Liquid ammonia storage tank DN1600 V=10m32.16/-20/5410DN1600x4400x12/14Q345R370052991800Setting pressure of safety valve is 2.22MPa, the maximum allowable working pressure is 2.27MPa3Liquid ammonia storage tank DN1800 V=15m32.16/-20/5415DN1800x5250x14/14Q345R503062492000Setting pressure of safety valve is 2.22MPa, the maximum allowable working pressure is 2.24MPa4Liquid ammonia storage tank DN2000 V=20m32.16/-20/5420DN2000x5650x16/16Q345R668067512200Setting pressure of safety valve is 2.22MPa, the maximum allowable working pressure is 2.26MPa5Liquid ammonia storage tank DN2200 V=25m32.16/-20/5425DN2200x5770x16/16(15)Q345R762070062400Setting pressure of safety valve is 2.22MPa, the maximum allowable working pressure is 2.22MPa6Liquid ammonia storage tank DN2200 V=30m32.16/-20/5430DN2200x7080x16/16(15)Q345R876083162400Setting pressure of safety valve is 2.22MPa, the maximum allowable working pressure is 2.22MPa7Liquid ammonia storage tank DN2400 V=30m32.16/-20/5430DN2400x5760x18/18(16.5)Q345R934070982600Setting pressure of safety valve is 2.22MPa, the maximum allowable working pressure is 2.22MPa8Liquid ammonia storage tank DN2400 V=40m32.16/-20/5440DN2400x7970x18/18(16.5)Q345R1178093082600Setting pressure of safety valve is 2.22MPa, the maximum allowable working pressure is 2.22MPa9Liquid ammonia storage tank DN2800 V=40m32.16/-20/5440DN2800x5490x20/22(20)Q345R1158070423000Setting pressure of safety valve is 2.23MPa, the maximum allowable working pressure is 2.32MPa10Liquid ammonia storage tank DN2400 V=50m32.16/-20/5450DN2400x10180x18/18(16.5)Q345R14900115182600Setting pressure of safety valve is 2.22MPa, the maximum allowable working pressure is 2.22MPa11Liquid ammonia storage tank DN2600 V=50m32.16/-20/5450DN2600x8480x18/20(18)Q345R1380099202800Setting pressure of safety valve is 2.22MPa, the maximum allowable working pressure is 2.22MPa12Liquid ammonia storage tank DN2800 V=50m32.16/-20/5450DN2800x7110x20/22(20)Q345R1436086623000Setting pressure of safety valve is 2.23MPa, the maximum allowable working pressure is 2.32MPa13Liquid ammonia storage tank DN2600 V=60m32.16/-20/5460DN2600x10360x18/20(18)Q345R16350118002800Setting pressure of safety valve is 2.22MPa, the maximum allowable working pressure is 2.22MPa14Liquid ammonia storage tank DN3000 V=80m32.16/-20/5480DN3000x10240x22/22(20.1)Q345R22560119023200Setting pressure of safety valve is 2.22MPa, the maximum allowable working pressure is 2.22MPa15Liquid ammonia storage tank DN3200 V=80m32.16/-20/5480DN3200x8810x22/24(22)Q345R22260105643400Setting pressure of safety valve is 2.22MPa, the maximum allowable working pressure is 2.26MPa16Liquid ammonia storage tank DN3000 V=100m32.16/-20/54100DN3000x13070x22/22(20.1)Q345R27200147323200Setting pressure of safety valve is 2.22MPa, the maximum allowable working pressure is 2.22MPa17Liquid ammonia storage tank DN3200 V=100m32.16/-20/54100DN3200x11290x22/24(22)Q345R26520130443400Setting pressure of safety valve is 2.22MPa, the maximum allowable working pressure is 2.26MPa18Liquid ammonia storage tank DN3600 V=120m32.16/-20/54120DN3600x10510x26/26(24)Q345R33120124663800Setting pressure of safety valve is 2.22MPa, the maximum allowable working pressure is 2.25MPa19Liquid ammonia storage tank DN3600 V=150m32.16/-20/54150DN3600x13460x26/26(24)Q345R40400154163800Setting pressure of safety valve is 2.22MPa, the maximum allowable working pressure is 2.25MPa20Liquid ammonia storage tank DN3800 V=200m32.16/-20/54200DN3800x16290x26/28(24)Q345R50395183484000Setting pressure of safety valve is 2.23MPa, the maximum allowable working pressure is 2.29MPa
Tanker LPG gas tanker series list:
Storage tanker (Under ground Horizontal type)
S/N
Name
Model number
Volume
Tanker dimensions(LxWxH)
Thickness of raw material (MM)
Seal head type
Loading weight
(KG)
Tanker weight(KG)
Others
1
lpg storage tank
DT1600-12
12 m3
6270x1620x2255DN1600x10
δ10
Double oval
4840
3298
2
lpg storage tank
DT2100-25
25 m3
7594x2124x2877DN2100x12
δ12
Double oval
10080
5688
3
lpg storage tank
DT2400-32
32 m3
7508x2428x3007DN2400x14
δ14
Double oval
12902
7460
4
lpg storage tank
DT2400-50
50 m3
11483x2428x3028 DN2400x14
δ14
Double oval
20160
10824
5
Propane gas storage tanker
DT2600-50
50 m3
9912x2628x3215DN2600x14
δ14
Double oval
20160
10229
6
Propane gas storage tanker
DT3000-80
80 m3
11866x3032x3610 DN3000x16
δ16
Double oval
32256
17900
7
Propane gas storage tanker
DT3200-100
100 m3
13010x3236x3716 DN3200x18
δ18
Double oval
40320
21228
8
Liquid ammonium storage tanker
DT2000-20
20 m3
6806x2028x2611DN2000x14
δ14
Double oval
10188
5585
9
Liquid ammonium storage tanker
DT2200-32
32 m3
8914x2232x2810DN2200x16
δ16
Double oval
16301
8795