AW45 intelligent universal low-voltage breaker
AW45 series intelligent circuit breaker (hereinafter referred to as breaker) is suitable for the circuit of AC 50Hz with rated voltage 400V, 690V and rated current up to 6300A. It is mainly used to distribute electric energy and protect circuit and power supply equipment from overload, under-voltage short-circuit, and single-phase earthing. With intelligent and selective protection Functions, the breaker can improve the reliability of power supply, and avoid unnecessary power failure. The breaker is applicable for power stations, factories, mines(for 690V) and modern high-building, especially for the distribution system of intelligent building. The breaker conforms to IEC60947-2. The whole series have past CCC certification and CE Certification.
Environment conditions for operation
Environmental temperature Tempeerature condition:-5oC ~+40oC ;the average value within 24h shall not exceed +35(Speial situation excluded )Elevation Altnmosphere condition Relative humidity at +40oC. shall not exceed 50%.higher hum-idity is permissible at lower temperature condition. when the highest monthly average relative humidity is 90% in the humiddext month,the lowest monthly average temperature of this month is +25oC.And consider the influence of dew on product surface due to temperature changes.pollution grade:grade The breaker should be installed caccording to the requirements on the instruction manual.The vertical inclination degree shall not exceed 5o
Outline and Installation Dimension
about us
Type | AW45-2000 | AW45-3200 | AW45-4000 | AW45-6300 | frame rated current Inm (A) | 2000320040006300
Number of poles | 3, 43, 43, 43, 4
Rated current In (A) | 630, 800, 1000, 1250, 1600, 20002000, 2500, 32002000, 2500, 3200, 40004000, 5000, 6300
Icu (kA) | 400V80100100120690V50656580
Ics = Icw (kA) | 400V508080100690V40505065
Rated current at N-pole In (A) | 50%In, 100%In
Inherent making breaking time | 23-32ms
Operational performance (operations) | Electric life500Mechanical lifeMaintenance-free2500 Maintenance 10000
Mounting mode | Fixed withdrawable
Arcing distance(mm) | 0
Intelligent controller | Standard type(M) telecommunication type (H)