Cable, Power Cable, Wire manufacturer / supplier in China, offering Ce Approved Wire XLPE Insulation PVC Sheathed Power Cable, 2019 Hot Selling IEC Standard AAC, All Aluminum Conductor, 50mm PVC Insulated and Sheathed Power Cable and so on.

1
    YRS
General Supplier
Supplier Homepage Electrical & Electronics Optical Fiber, Cable & Wire Power Cable China 22kv Medium Voltage Underground XLPE Power Cables

China 22kv Medium Voltage Underground XLPE Power Cables

Get Latest Price
Min. Order / Reference FOB Price
1000 Meter US $1.00/ Meter
Local Area: Zhengzhou, Henan, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Application: Construction, Underground
Voltage: Low and Medium Voltage Cable
Current: DC & AC
22kV Medium Voltage Underground XLPE Power Cables
Application:
Media Voltage XLPE Insulated power cable is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable.
Prpperty:
1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.
2.In short circuit (Max long term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degrees.
3.The cable is laid without horizontal drop limit. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.
4.Excellent electrical performance, resistance to chemical corrosion.
5.They can stand advisable traction when laid.They can stand traction from Outside.Left low smoke halogen-free after burned.Retard the burning of the cable.
Specification:
Standard:
IEC60502,designing and manufacturing special power cable according to the other standards required by the customers.
1)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable


Normal Cross Section of Conductor
Normal Diameter of Conductor
Normal Thickness of Insulation
Normal Thickness of
Copper Tape
Normal Thickness of Outer Sheath
Approx.
Overall Dia.
Approx. Net Weight
Max. D.C. Resistance of Conductor at 20ºC
Al Conductor
Cu Conductor
Al Conductor
Cu Conductor
mm2
mm
mm
mm
mm
mm
kg/m
kg/m
Ω/km
Ω/km
25
6.0
2.5
0.12
1.5
17.6
0.34
0.49
1.2000
0.7270
35
7.0
2.5
0.12
1.5
18.5
0.39
0.60
0.8680
0.5240
50
8.3
2.5
0.12
1.6
20.0
0.46
0.74
0.6410
0.3870
70
9.7
2.5
0.12
1.6
21.5
0.55
0.96
0.4430
0.2680
95
11.3
2.5
0.12
1.7
23.3
0.66
1.23
0.3200
0.1930
120
13
2.5
0.12
1.7
24.8
0.77
1.48
0.2530
0.1530
150
14.6
2.5
0.12
1.8
26.4
0.87
1.77
0.2060
0.1240
185
15.9
2.5
0.12
1.8
28.1
1.01
2.13
0.1640
0.0991
240
18.3
2.6
0.12
1.9
30.9
1.23
2.71
0.1250
0.0754
300
20.4
2.8
0.12
2.0
33.6
1.48
3.32
0.1000
0.0601
400
23.2
3.0
0.12
2.1
37.0
1.81
4.16
0.0778
0.0470
500
26.4
3.2
0.12
2.2
41.1
2.24
5.27
0.0605
0.0366
630
30.1
3.2
0.12
2.3
45.0
2.73
6.62
0.0469
0.0283


2)6/10(12)kV,6.35/11(12)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable


Normal Cross Section of Conductor
Normal Diameter of Conductor
Normal Thickness of Insulation
Normal Thickness of
Copper Tape
Normal Thickness of Outer Sheath
Approx.
Overall Dia.
Approx. Net Weight
Max. D.C. Resistance of Conductor at 20ºC
Al Conductor
Cu Conductor
Al Conductor
Cu Conductor
mm2
mm
mm
mm
mm
mm
kg/m
kg/m
Ω/km
Ω/km
25
6.0
3.4
0.12
1.5
19.4
0.40
0.55
1.2000
0.7270
35
6.9
3.4
0.12
1.6
20.5
0.45
0.66
0.8680
0.5240
50
8.2
3.4
0.12
1.6
21.8
0.52
0.80
0.6410
0.3870
70
9.7
3.4
0.12
1.7
23.5
0.62
1.03
0.4430
0.2680
95
11.3
3.4
0.12
1.7
25.1
0.73
1.30
0.3200
0.1930
120
12.8
3.4
0.12
1.8
26.8
0.85
1.56
0.2530
0.1530
150
14.2
3.4
0.12
1.8
28.2
0.95
1.85
0.2060
0.1240
185
15.9
3.4
0.12
1.9
30.1
1.10
2.22
0.1640
0.0991
240
18.3
3.4
0.12
2.0
32.7
1.33
2.80
0.1250
0.0754
300
20.4
3.4
0.12
2.0
34.8
1.54
3.39
0.1000
0.0601
400
23.2
3.4
0.12
2.2
38.0
1.87
4.22
0.0778
0.0470
500
26.4
3.4
0.12
2.2
41.5
2.26
5.29
0.0605
0.0366
630
30.1
3.4
0.12
2.4
45.6
2.78
6.67
0.0469
0.0283


3)8.7/10(15)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable


Normal Cross Section of Conductor
Normal Diameter of Conductor
Normal Thickness of Insulation
Normal Thickness of
Copper Tape
Normal Thickness of Outer Sheath
Approx.
Overall Dia.
Approx. Net Weight
Max. D.C. Resistance of Conductor at 20ºC
Al Conductor
Cu Conductor
Al Conductor
Cu Conductor
mm2
mm
mm
mm
mm
mm
kg/m
kg/m
Ω/km
Ω/km
25
6.0
4.5
0.12
1.6
21.8
0.48
0.63
1.2000
0.7270
35
6.9
4.5
0.12
1.7
22.9
0.54
0.75
0.8680
0.5240
50
8.2
4.5
0.12
1.7
24.2
0.61
0.89
0.6410
0.3870
70
9.7
4.5
0.12
1.8
25.9
0.72
1.13
0.4430
0.2680
95
11.3
4.5
0.12
1.8
27.5
0.84
1.40
0.3200
0.1930
120
12.8
4.5
0.12
1.9
29.2
0.96
1.67
0.2530
0.1530
150
14.2
4.5
0.12
1.9
30.6
1.06
1.96
0.2060
0.1240
185
15.9
4.5
0.12
2.0
32.5
1.22
2.34
0.1640
0.0991
240
18.3
4.5
0.12
2.1
35.1
1.46
2.93
0.1250
0.0754
300
20.4
4.5
0.12
2.1
37.2
1.68
3.52
0.1000
0.0601
400
23.2
4.5
0.12
2.2
40.2
2.00
4.35
0.0778
0.0470
500
26.4
4.5
0.12
2.3
43.9
2.43
5.45
0.0605
0.0366
630
30.1
4.5
0.12
2.4
47.8
2.93
6.83
0.0469
0.0283


4)12/20(24)kV, 12.7/22(24)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable


Normal Cross Section of Conductor
Normal Diameter of Conductor
Normal Thickness of Insulation
Normal Thickness of
Copper Tape
Normal Thickness of Outer Sheath
Approx.
Overall Dia.
Approx. Net Weight
Max. D.C. Resistance of Conductor at 20ºC
Al Conductor
Cu Conductor
Al Conductor
Cu Conductor
mm2
mm
mm
mm
mm
mm
kg/m
kg/m
Ω/km
Ω/km
25









35
6.9
5.5
0.12
1.7
24.9
0.62
0.83
0.8680
0.5240
50
8.2
5.5
0.12
1.8
26.4
0.70
0.98
0.6410
0.3870
70
9.7
5.5
0.12
1.8
27.9
0.80
1.21
0.4430
0.2680
95
11.3
5.5
0.12
1.9
29.7
0.94
1.50
0.3200
0.1930
120
12.8
5.5
0.12
1.9
31.2
1.05
1.77
0.2530
0.1530
150
14.2
5.5
0.12
2.0
32.8
1.17
2.07
0.2060
0.1240
185
15.9
5.5
0.12
2.0
34.5
1.33
2.45
0.1640
0.0991
240
18.3
5.5
0.12
2.1
37.1
1.57
3.04
0.1250
0.0754
300
20.4
5.5
0.12
2.2
39.4
1.81
3.66
0.1000
0.0601
400
23.2
5.5
0.12
2.3
42.4
2.14
4.49
0.0778
0.0470
500
26.4
5.5
0.12
2.4
46.1
2.58
5.61
0.0605
0.0366
630
30.1
5.5
0.12
2.4
49.8
3.10
6.99
0.0469
0.0283


5)18/30(36)kV,19/33(36)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable


Normal Cross Section of Conductor
Normal Diameter of Conductor
Normal Thickness of Insulation
Normal Thickness of
Copper Tape
Normal Thickness of Outer Sheath
Approx.
Overall Dia.
Approx. Net Weight
Max. D.C. Resistance of Conductor at 20ºC
Al Conductor
Cu Conductor
Al Conductor
Cu Conductor
mm2
mm
mm
mm
mm
mm
kg/m
kg/m
Ω/km
Ω/km
25









35









50
8.2
8.0
0.12
2.0
31.8
0.95
1.23
0.6410
0.3870
70
9.7
8.0
0.12
2.0
33.3
1.07
1.47
0.4430
0.2680
95
11.3
8.0
0.12
2.1
35.1
1.21
1.78
0.3200
0.1930
120
12.8
8.0
0.12
2.1
36.6
1.34
2.05
0.2530
0.1530
150
14.2
8.0
0.12
2.2
38.2
1.47
2.37
0.2060
0.1240
185
15.9
8.0
0.12
2.2
39.9
1.64
2.76
0.1640
0.0991
240
18.3
8.0
0.12
2.3
42.5
1.90
3.37
0.1250
0.0754
300
20.4
8.0
0.12
2.4
44.8
2.16
4.01
0.1000
0.0601
400
23.2
8.0
0.12
2.4
47.6
2.52
4.87
0.0778
0.0470
500
26.4
8.0
0.12
2.5
51.3
2.98
6.01
0.0605
0.0366
630
30.1
8.0
0.12
2.6
55.2
3.54
7.43
0.0469
0.0283


6)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable


Normal Cross Section of Conductor
Normal Diameter of Conductor
Normal Thickness of Insulation
Normal Thickness of
Copper Tape
Normal Thickness of Outer Sheath
Approx.
Overall Dia.
Approx. Net Weight
Max. D.C. Resistance of Conductor at 20ºC
Al Conductor
Cu Conductor
Al Conductor
Cu Conductor
mm2
mm
mm
mm
mm
mm
kg/m
kg/m
Ω/km
Ω/km
25
6.0
2.5
0.1
2.0
34.6
1.13
1.58
1.2000
0.7270
35
6.9
2.5
0.1
2.1
36.8
1.29
1.92
0.8680
0.5240
50
8.2
2.5
0.1
2.2
39.8
1.51
2.36
0.6410
0.3870
70
9.7
2.5
0.1
2.3
43.2
1.81
3.04
0.4430
0.2680
95
11.3
2.5
0.1
2.4
46.9
2.17
3.87
0.3200
0.1930
120
12.8
2.5
0.1
2.4
50.1
2.53
4.69
0.2530
0.1530
150
14.2
2.5
0.1
2.5
53.3
2.90
5.60
0.2060
0.1240
185
15.9
2.5
0.1
2.6
57.2
3.40
6.77
0.1640
0.0991
240
18.3
2.6
0.1
2.8
63.2
4.12
8.55
0.1250
0.0754
300
20.4
2.8
0.1
3.0
69.0
4.89
10.46
0.1000
0.0601
400
23.2
3.0
0.1
3.4
76.7
6.10
13.18
0.0778
0.0470
500
26.4
3.2
0.1
3.6
85.7
8.10
16.55
0.0605
0.0366


7)6/10(12)kV,6.35/11(12)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable


Normal Cross Section of Conductor
Normal Diameter of Conductor
Normal Thickness of Insulation
Normal Thickness of
Copper Tape
Normal Thickness of Outer Sheath
Approx.
Overall Dia.
Approx. Net Weight
Max. D.C. Resistance of Conductor at 20ºC
Al Conductor
Cu Conductor
Al Conductor
Cu Conductor
mm2
mm
mm
mm
mm
mm
kg/m
kg/m
Ω/km
Ω/km
25
6.0
3.4
0.1
2.1
38.7
1.30
1.75
1.2000
0.7270
35
6.9
3.4
0.1
2.2
40.9
1.47
2.22
0.8680
0.5240
50
8.2
3.4
0.1
2.3
43.9
1.70
2.50
0.6410
0.3870
70
9.7
3.4
0.1
2.4
47.3
2.02
3.25
0.4430
0.2680
95
11.3
3.4
0.1
2.5
51.0
2.42
4.12
0.3200
0.1930
120
12.8
3.4
0.1
2.6
54.4
2.79
4.95
0.2530
0.1530
150
14.2
3.4
0.1
2.7
57.6
3.17
5.87
0.2060
0.1240
185
15.9
3.4
0.1
2.8
61.5
3.69
7.06
0.1640
0.0991
240
18.3
3.4
0.1
2.9
66.9
4.38
8.82
0.1250
0.0754
300
20.4
3.4
0.1
3.1
71.8
5.11
10.68
0.1000
0.0601
400
23.2
3.4
0.1
3.3
78.3
6.24
13.32
0.0778
0.0470
500
26.4
3.4
0.1
3.5
86.4
7.63
16.50
0.0605
0.0366


8)8.7/10(15)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable


Normal Cross Section of Conductor
Normal Diameter of Conductor
Normal Thickness of Insulation
Normal Thickness of
Copper Tape
Normal Thickness of Outer Sheath
Approx.
Overall Dia.
Approx. Net Weight
Max. D.C. Resistance of Conductor at 20ºC
Al Conductor
Cu Conductor
Al Conductor
Cu Conductor
mm2
mm
mm
mm
mm
mm
kg/m
kg/m
Ω/km
Ω/km
25
6.0
4.5
0.1
2.3
43.9
1.57
2.02
0.9270
0.7270
35
6.9
4.5
0.1
2.4
46.0
1.75
2.38
0.6680
0.5240
50
8.2
4.5
0.1
2.4
48.8
2.00
2.85
0.4936
0.3870
70
9.7
4.5
0.1
2.5
52.3
2.34
3.57
0.3420
0.2680
95
11.3
4.5
0.1
2.6
55.9
2.75
4.45
0.2464
0.1930
120
12.8
4.5
0.1
2.7
59.4
3.16
5.32
0.1955
0.1530
150
14.2
4.5
0.1
2.8
62.6
3.57
6.27
0.1587
0.1240
185
15.9
4.5
0.1
2.9
66.4
4.07
7.45
0.1271
0.0991
240
18.3
4.5
0.1
3.1
72.0
4.82
9.25
0.0976
0.0754
300
20.4
4.5
0.1
3.3
77.0
5.71
11.28
0.0778
0.0601
400
23.2
4.5
0.1
3.4
83.2
6.78
13.86
0.0615
0.0470
500
26.4
4.5
0.1
3.5
91.1
8.20
17.32
0.0487
0.0366


9)12/20(24)kV, 12.7/22(24)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable


Normal Cross Section of Conductor
Normal Diameter of Conductor
Normal Thickness of Insulation
Normal Thickness of
Copper Tape
Normal Thickness of Outer Sheath
Approx.
Overall Dia.
Approx. Net Weight
Max. D.C. Resistance of Conductor at 20ºC
Al Conductor
Cu Conductor
Al Conductor
Cu Conductor
mm2
mm
mm
mm2
mm
mm
kg/m
kg/m
Ω/km
Ω/km
25
-








35
6.9
5.5
0.1
2.4
50.3
2.00
2.63
0.8680
0.6680
50
8.2
5.5
0.1
2.5
53.3
2.26
3.11
0.6410
0.4936
70
9.7
5.5
0.1
2.6
56.8
2.62
3.85
0.4430
0.3420
95
11.3
5.5
0.1
2.8
60.6
3.07
4.77
0.3200
0.2464
120
12.8
5.5
0.1
2.9
64.1
3.49
5.65
0.2530
0.1955
150
14.2
5.5
0.1
3.0
67.3
3.91
6.61
0.2060
0.1587
185
15.9
5.5
0.1
3.1
71.2
4.44
7.81
0.1640
0.1271
240
18.3
5.5
0.1
3.3
76.8
5.21
9.64
0.1250
0.0976
300
20.4
5.5
0.1
3.3
81.3
6.10
11.66
0.1000
0.0778
400
23.2
5.5
0.1
3.5
87.7
7.20
14.28
0.0778
0.0615
500
26.4
5.5
0.1
3.8
96.0
9.15
17.80
0.0605
0.0487


10)18/30(36)kV,19/33(36)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable


Normal Cross Section of Conductor
Normal Diameter of Conductor
Normal Thickness of Insulation
Normal Thickness of
Copper Tape
Normal Thickness of Outer Sheath
Approx.
Overall Dia.
Approx. Net Weight
Max. D.C. Resistance of Conductor at 20ºC
Al Conductor
Cu Conductor
Al Conductor
Cu Conductor
mm2
mm
mm
mm
mm
mm
kg/m
kg/m
Ω/km
Ω/km
25









35









50
8.2
8.0
0.1
2.9
64.9
3.02
3.87
0.6410
0.4936
70
9.7
8.0
0.1
3.0
68.4
3.42
4.65
0.4430
0.3420
95
11.3
8.0
0.1
3.1
72.0
3.89
5.59
0.3200
0.2464
120
12.8
8.0
0.1
3.3
75.7
4.39
6.54
0.2530
0.1955
150
14.2
8.0
0.1
3.3
78.7
4.85
7.55
0.2060
0.1587
185
15.9
8.0
0.1
3.4
82.6
5.42
8.79
0.1640
0.1271
240
18.3
8.0
0.1
3.5
88.0
6.22
10.66
0.1250
0.0976
300
20.4
8.0
0.1
3.7
92.9
7.20
12.77
0.1000
0.0778
400
23.2
8.0
0.1
3.9
99.3
8.38
15.46
0.0778
0.0615
500
26.4
8.0
0.1
4.2
107.6
10.15
18.85
0.0605
0.0487