Business Type:
Manufacturer/Factory
Establishment:
2012
R&D Capacity:
ODM, OEM, Other
OEM/ODM Service
Sample Available

7kw EV Charger, Power Supply, Adapter manufacturer / supplier in China, offering 7kw EV Charger Power Supply, 30kw & Power Module, 15kw & Power Module and so on.

1
    YRS
General Supplier
Supplier Homepage Electrical & Electronics Inverter Power Inverter China 3000va off-Grid Solar PV Inverter for Energy Storage

China 3000va off-Grid Solar PV Inverter for Energy Storage

Get Latest Price
Min. Order / Reference FOB Price
1 Pieces Contact Supplier
Local Area: Shenzhen, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Nature of Source Flow: Solar PV Inverter
Certification: CCC, UL, CE
Output Power: 3kw
GPDA3000VA-I is one model from Goldpower Off-Grid inverter series, with AC bypass input and RS485 communication
1. Flexible and efficient
2. Easy installation
3. Safe and reliable
1. Emergency ESS
Residential ESS
3. Commercial ESS

ModelGPDA3000VA-CRemarkItem Parameter DC InputDC operating voltage range40~58Vdc DC startup
voltage range42~56Vdc Rated input voltage48Vdc Input current80Arated input,rated output.Startup Max. inrush input150A AC outputRated output voltage220Vac Rated output current1091Apower factor 0.8Output stabilized voltage precision±5% Rated output frequency50Hz Rated capacity3000VA Rated output power2400W output efficiency88%Under rated operating conditionsoutput power factor0.8Under rated operating conditionsDynamic transient recovery time100ms Voltage waveformSine wave
THD<3%Linear loadSine wave
THD<8%Non-linear loadOver load ability105 ~ 125% sustained no less than 60s, 125 ~ 150% sustained no less than 10sOutput current peak coefficient3:1Output methodTwo national standard socket, a wiring output, each output of a single pole open controlInverse conversion bypass conversion time<5ms Power supply priority modeInversion priority ProtectionDC input under voltage protection point37~40 Vdcwith half load testDC input under voltage recovery point40~42 VdcReached to the recovery value,auto recovery.DC input over voltage protection point58~60 Vdcwith half load testDC input over voltage recovery point56~58 VdcReached to the recovery value,auto recovery.Over temp. protectionWhen the main radiator temperature is too high, up to over-temperature protection point, turn off the output, the temperature hysteresis is about 10 ºC.Anti-reverse protectionWhen the input reverse, the power does not work, and no damageShort circuit protectionWhen a short circuit is detected, the power is turned off and an alarm signal is issued. It is automatically restarted every 30 seconds. After the fault is removed, it can be restored. Long-term short circuit, the power off lock, re-boot can work properly.Over current protectionWhen overcurrent is detected, the power is turned off and an alarm signal is issued. When the load returns to the rated value, it can be restored. Long-term overload, the power off lock, re-boot can resume normal work.Alarm function(sharp alarm)DC input abnormal, overload, short circuit, inverter failure, the wind alarm, while warning lights.AmbientOperating temp.-5~+40ºC Storage inverter temp.-25~+70ºC Relative humidity0~95% Altitude3000m CoolingForced air cooling Operating ambientNo conductive explosion of dust, no corrosion and damage to the gas and steam, no severe vibration and shock.InsulationParameterStandard requirementRemarkDielectric strengthInput-output:2000Vac/10mA//1minNo flash, no breakdownInput-earth:500Vdc/10mA//1minOutput-earth:1500Vac/10mA//1miInsulation resistanceAt normal atmospheric pressure, the relative humidity of 95%, the test voltage is DC 500V, the power input to the output, input to the ground, the output to the ground insulation resistance of not less than 10MΩ.EMCConductioncomply to standard YD/T983-1998 ARadiationcomply to standard YD/T983-1998 AImmunitycomply to standard YD/T983-1998 ANoise<55dB(1meter)The shell protection levelIP20(indoor)SmellNo smell and other harmful smell to healthMechanicalDimension481.6*270*88.1 mm Weight≤4KG