Business Type:
Manufacturer/Factory
Establishment:
2012
R&D Capacity:
ODM, OEM, Other
OEM/ODM Service
Sample Available

Sectionalizer, Auto Circuit Breaker, Distribution manufacturer / supplier in China, offering 15kv/27kv/38kv Recloser Wtith IEC61850 and DNP3.0 for Distribution and Substation, Pasgt Tactical M88 U. S. Army Steel Replica Anti-Riot Helmet Full Head Coverage with Adjustable Chin Strap for Personal Safety of Airsoft Hunting Paint Ball Bb, Od8mm Stainless Steel Bowfishing Line Guiding Rod with Ceramic Eyelet Accessory Fit Reel Seat Mount for Fishing Bow Fishing Slingshot and so on.

1
    YRS
General Supplier
Supplier Homepage Electrical & Electronics Capacitor China 300kv Capacitor Voltage Transformer

China 300kv Capacitor Voltage Transformer

Get Latest Price
Min. Order / Reference FOB Price
10 Piece US $100000.00/ Piece
Local Area: Ningbo, Zhejiang, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Type: High Frequency Ceramic Capacitor
Application: Power
Packaging Type: Through Hole

This series of capacitor voltage transformers include the products with the type of TYO 150//'3-0.01 H (TYD161/v3-0.01 H), TYD150~13-0.02H (TYD161/v3-0.02H), TYD220~-0.00SH, TYD220~- 0.01 H, TYD330kv/110v-0.00SH, TYD330kv/115v-0.01H, TYD500kv~110v-0.00SH etc., which can be used for electric measurement and relay protection in the electric power system with a voltage of 150~500kV and frequency of 50Hz. The products are in accordance with the requirements of the standard GB 4 703 "Capacitor Voltage Transformers",GB19749 "Coupling capacitors and capacitor voltage dividers" & IEC 60044-5 "Capacitor Voltage Transformers".

TECHNICAL DATA SCHEDULE
CAPACITOR VOLTAGE TRANSFORMER 330 kV
CODE NO: 4132ITEMDEscriptIONUNITSREQUIREDGUARANTEED1.01.1Type--Capacitive1.2
1.3Model no
Country of Origin-
--
TYD330/√3-0.0044H 2.02.1Voltage2.1.1Rated voltagekV3303302.1.2Rated voltage classKV3623622.2Rated frequencyHz50502.3Network neutral grounding-EffectiveEffective2.4Rated voltage factor for 30 s-1,51.52.5Rated lightning impulse withstandkV117511752.6Chopped lighting impulse withstand (3 ms)kV129012902.7Switching impulse withstand (wet)kV9509502.8Power frequency withstand voltage (1 min)kV4504502.9Creepage distancemm/kV31312.10Max. radio interference voltage at 0,5 MHz per IEC 694mV250025002.11Capacitance C1 and C2pf440044002.12Series reactor
- inductance range
- resistance range
mH
ohms
0.2
-0.2

4002.13Transformation ratio- 330kV/Ö3
: 0,11kV/Ö3
: 0,11kV/Ö3
(: 0,11kV/Ö3)330kV/√3
: 0,11kV/√3
: 0,11kV/√3 2.14Transformer characteristics
- HV/LV turn ratio range
- Normal operating flux density
-
tesla
-
-
3000:1
0.5T2.15Primary voltagekV330/Ö3330/Ö32.16Secondary voltageV110/Ö3110/Ö32.17Winding accuracy: - metering class-0,20,2 - protection class-3P3P - burden ( on each winding)VA50502.18Number of secondary winding-2 (3)22.19Winding conductor-CuCU2.20Circuit Diagram-To be enclosed with bidTo be enclosed with bid2.21HV Terminal connector for-TBA3.03.1Weight for operationkg-9503.2Weight for transportkg-10003.3Heightm-43703.4Shipping dimensions (H x W x D)m-800*700*26003.5Outline drawing number-To be enclosed with bidTo be enclosed with bid4.0-To be enclosed with bidTo be enclosed with bid5.0-IEC 60044-5
IEC 60694
IEC 60947-1IEC 60044-5
IEC 60694
IEC 60947-16.0-ISO -----------ISO9001 7.0-Outdoor, Substation SwitchyardOutdoor, Substation Switchyard8.0-Outdoor in substation switchyard