Business Type:
Manufacturer/Factory
Business Range:
Power Transformer
Establishment:
2013
R&D Capacity:
ODM, OEM
Terms of Payment:
LC, T/T
Main Markets:
South America, Southeast Asia, Middle East, Africa
OEM/ODM Service
Sample Available

Ring Main Unit, Load Break Switch, Load Switch manufacturer / supplier in China, offering 12kV/24kV/36kV Ring Main Unit (SM66), Rps-Improvement Type Gas Insulated Lbs/Sectionalizer/Pole Mount Type Sf6 Gas Insulated Load Break Switch, 38kv Gas Insulated Lbs/ Sectionalizer and so on.

1
    YRS
General Supplier
Supplier Homepage Electrical & Electronics Power Supply & Distribution Switchgear China 33kv High Voltage Sf6 Gas Fully Insulated Ring Main Unit

China 33kv High Voltage Sf6 Gas Fully Insulated Ring Main Unit

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $30000.00/ Piece
Local Area: Wenzhou, Zhejiang, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T
Certification: ISO9001
Shell Material: Aluminum Alloy
Voltage Level: Medium Voltage
Product Description
iSafering SF6 insulated Ring Main Unit
Gas Insulated Ring Main Unit
iSafeRing is a SF6 insulated ring main unit for the secondary distribution network. iSafeRing can be supplied in 10 different configurations suitable for most switching applications in 12/24/36 kV distribution networks. As an option, iSafeRing can be delivered as extendable ring main unit.
Together, iSafeRing represent a complete solution for 12/24/36 kV secondary distribution networks.

C - Cable switch moduleF - Cable switch moduleV - Cable switch moduleD - Direct cable connection moduleDe - Direct cable connection module with earthing switchM - Metering module


Modularity and external busbar
All modules except the metering module and circuit-breaker module are only 325 mm wide.
Transformer protection
iSafering offers a choice between a switch fuse combination and circuit breaker with relay for transformer protection. The switch fuse combination offers optimal protection against short-circuits, while the circuit breaker with relay option offers better protection against low overcurrents. Circuit breaker with relay is always recommended for larger transformers.
Normal operation conditions
The rated characteristics of the switchgear are valid under the following ambient conditions:
minimum ambient temperature: - 25 °C
maximum ambient temperature: + 40 °C
For different temperature ranges, please contact your UNISUN sales representative.
Standards
iSafeRing/iSafePlus is tested according to following
IEC-standards:
IEC 62271-1/IEC 62271-100/IEC 62271-102/IEC 62271-103/IEC 62271-105/IEC 62271-200/IEC 60529:

SF6 insulated Ring Main Unit Outer assembly


iSafering outer assemblyUpper front cover
1. Manometer
2. Nameplate module
3. Short circuit indicator
4. Capacitive voltage indication
5. Load break / earthing switch position indicator
6. Push buttons close/open operation
7. Charged spring indicator
8. Self-powered protection relay
9. Vacuum circuit-breaker position
10. Operation shaft
11. Padlock device
Lower front cover
12. Nameplate switchgear
13. Fuse blown indicator
14. Disconnector / earthing switch position indicator
15. Capacitive voltage indication
Cable compartment cover
16. Cable compartment cover standard
17. Cable compartment cover with inspection window
18. Support bar (removable)
Side cover
19. Lifting lug
20. Operating handle (standard on right hand side)

Inner assembly


1. Mechanism compartment
2. SF6 gas tank
3. Cable compartment
4. Pressure relief area


Technical data

SafeRingC-moduleF-moduleV-moduleSwitch disconnectorEarthing switchSwitch-fuse disconnectorDownstream earthing switchVacuum circuit-breakerEarthing switch/ disconnectorRated voltageKv12/17,5/2412/17,5/2412/17,5/2412/17,5/2412/17,5/2412/17,5/24Rated frequency 5)Hz50/50/5050/50/5050/50/5050/50/5050/50/5050/50/50Power frequency withstand voltagekV28/38/5028/38/5028/38/5028/38/5028/38/5028/38/50Lightning impulse withstand voltagekV95/95/12595/95/12595/95/12595/95/12595/95/12595/95/125Rated normal currentA630/630/630 2001) 200/200/200 Breaking capacities: active loadA630/630/630 closed loopA650/650/650 off load cable chargingA140/140/140 off load transformerA 20/20/20earth-faultA205/160/160 earth-fault cable chargingA117/91/91 short-circuit breaking currentkV see2) 16/16/16 Making capacitykV52,5/40/4052,5/40/40see2)12,5/12,5/12,540/40/4040/40/40Short time current 3 sec. 3)kV21/16/1621/16/16 16/16/1616/16/16