Sectionalizer, Auto Circuit Breaker, Distribution manufacturer / supplier in China, offering 15kv/27kv/38kv Recloser Wtith IEC61850 and DNP3.0 for Distribution and Substation, Pasgt Tactical M88 U. S. Army Steel Replica Anti-Riot Helmet Full Head Coverage with Adjustable Chin Strap for Personal Safety of Airsoft Hunting Paint Ball Bb, Od8mm Stainless Steel Bowfishing Line Guiding Rod with Ceramic Eyelet Accessory Fit Reel Seat Mount for Fishing Bow Fishing Slingshot and so on.

1
    YRS
General Supplier

China 38kv Pole Mounted 630A 60z Recloser

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $10000.00/ Piece
Local Area: Ningbo, Zhejiang, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Breaking Capacity: High Voltage Circuit Breakers
Operation: Electric Type
Speed: High-Speed Circuit Breaker


A.- THREE PH ASE RECLOSER 33 KV ITEMDEscriptIONUNITREQUIREDGUARANTEED1RECLOSER1.01COUNTRY TO INDICATECHINA1.02MANUFACTURER TO INDICATEHEMG1.03MODEL TO INDICATECHZ41.04STANDARD ANSI C-37.60YES1.05TYPE OUTDOORYES1.06SYSTEM THREE PHASEYES1.07OPERATION TYPE AUTOMATIC AND MANUALYES1.08ALTITUDE OF OPERATIONMO.S.L2500 OR MOREYES ELECTRIC CHARACTERISTICS YES1.09OPERATION VOLTAGEKV33YES1.10MAX, VOLTAGE OF THE EQUIPMENTKV38YES1.11NOMINAL FREQUENCYHZ60YES1.12NOMINAL CURRENTA630YES1.13NOMINAL SYMETRIC INTERRPTION CURRENTKA12.5YES1.14SPECIFIC LEAKAGE DISTANCEmm/KV31YES1.15BILKV170YES1.16DISCHARGE VOLTAGE, DRY, 60 HZ, 1 MINUTEKV70YES1.17DISCHARGE VOLTAGE, WET, 60 HZ, 10 SECONDSKV60YES1.18CYCLE OF WORK ACCORD ANSI C-37.60 YESYES1.19INTERRUPTIION WAY VACUUMYES1.20INSULATION WAY SOLID DIELECTRIC OR GAS SF6YES1.21NUMBER OF ELECTRIC OPERATIONS 10000YES1.22CURRENT MEASURE WITH CURRENT SENSORSYES INSTALLATION INDOORYES SYSTEM SINGLE PHASEYES1.23RELATION OF TRANSFORMATIONA400/1.YES1.24PRECISION%1%YES1.25VOLTAGE MEASURE VOLTAGE SENSORS INTERNALYES1.26TYPE CAPACITIVEYES1.27INSTALLATION IN BUSHINGYES1.28PRECISION%2.5YES1.29QUANTITY 6YES1.3SENSITIVE GROUND FAULT CURRENT DETECTION. CURENT TRANSFORMERYES INSTALLATION. IN THE TANK (INSIDE THE TANK )IN ConTROL TANK QUANTITY. 1YES TRANSFORMATION RELATION.Ma200/1.5YES MECHANIC CHARACTERISTICS1.3metaLLIC HARDWARE MATERIAL STAINLESSYES STANDARD OF THE MATERIAL ASTM A575YES STANDARD OF HOT GALVANIZED ASTM A 153YES THICKNEES OF GALAVANIZATION MINgr/CM2800YES1.31MOUNTING ON CIRCULAR POLEYES1.32MECHANISM OF OPERATION MAGNETIC ACTUATORYES1.33POSITION INDICATOR VISIBLE FROM THE SOILYES1.34OPERATION BETWEEN POLE WITH HOOK YESYES1.35MANUAL LOCKING EMERGENCY (ATTACHED DRAWING) YESYES1.36TOOL PROVIDED WITH MANUAL CONTROL YESYES1.37 WITH LIFTING HOOKS YESYES1.38INDICATES THE LIFE OF CONTACTS YESYES1.39NUMBER OF MECHANICS OPERATION 10000 OR MOREYES1.40FULLY ASSEMBLED YESYES1.41WEIGHT YES PRINCIPAL TANKKGTO INDICATE75KG ConTROL BOXKGTO INDICATE35KG2TANK2.01MATERIAL STAINLESS STEELYES ConSTRUCTION REQUIREMENTS INDICATE THE STANDARDYES2.02 COATING OF TIN IN TERMINALS AND ConDUCTIVE PARTS. 8 umYES2.03PROTECTION DEGREE Able to withstand pressure fresh water cleaning insulators.YES3BUSHINGS3.01COUNTRY TO INDICATEZSW3.02MANUFACTURER TO INDICATEHM3.03STANDARD ASTM D624, DIN 63504,IEC 60587,ASTM G154, AST G 155.
YES3.04CHARACTERISTICS OF MANUFACTURE MATERIAL OF CORE FIBER GLASS OR RESYNYES INSULATION MATERIAL OF COVER HOUSING AND SHEDS Cycloaliphatic EPOXY RESINYES ELonGATION AT BREAK%450 ( ACCORD STANDARD DIN 53504 )YES3.05TEAR RESISTANCE.N/MMAJOR OF 20 ( Standard ASTM D624)YES3.06TRACKING AND EROSION RESISTANCE. CLASS 2A,4.5 ( IEC 60587 )YES3.07TESTING OF RESISTANCE TO UV RAYS. ACCORDING ASTM G154 AND ASTM G155YES3.08RANGE OF SECTION OF DRIVERS. 16 TO 120 MM2YES3.09ConDUCTOR MATERIAL OF ELIGIBLE. CU/AL , CU/CU , AL/ALYES4SYSTEM OF ConTROL AND PROTECTION 4.01COUNTRY SAME COUNTRY INDICATE POINT 1.1YES4.02STANDARD OF MANUFACTURE ANSI / IEEE 37.90YES4.03INSTALLATION OUTDOORYES4.04MANUFACTURER SAME MANUFACTURER INDICATE POINT 1.2YES4.05CATALOGUE TO INDICATEYES4.06MODEL OF ELECTRonIC SYSTEM TO INDICATECHK4 ConTROLBOX4.07MATERIAL STAINLESS STEELYES4.08THICKNESS 2 MMYES4.09SURFACE BRIGHT PASSIVATINGYES4.10COLOUR TO INDICATEGREY4.11PROTECTION DEGRE OF THE BOX CLOSE OPEN IP65CLOSE IP65 INSULATION VOLTAGE TO 1 MINUTE 2 KVYES INSULATION VOLTAGE TO IMPULSE 6 KVpYES SUPPORT TO INTERFERENCE TESTING ACCORDING TO STANDARDS: SWC ANSI C37.90.1, IEC 61000-4-4-YES IMMUNITY TO INTERFERENCE RADIO WAVES. IEC 255-22-3 CLASS, ANSI C37.90.2YES4.12WITH NAMEPLATE YESYES CHARACTERISTICS 4.13FUNCTION WITH MICROPROCESSORYES4.14PRINCIPAL PROTECTIONS 50/51,50N/51N,SEF,25,27,59,59N, 67YES4.15SEConDARY PROTECTIONS 46.81YES4.16ADJUSTEMENT GROUPS 2 MINYES4.17MIN CURRENT OF SHOOT YES FAILURE BETWEEN PHASESA20 or minorYES FAILURE TO GROUNDA10 or minorYES SENSITIVY FAILUREA1 or minorYES4.18SETTING ALLOWS PARAMETERS PROTECTION YESYES IEC STANDARD CURVES YESYES CUSTOM CURVES YESYES4.19FAILURE TO GROUND YESYES4.20MINIMUN VOLTAGES YESYES4.21OVER VOLTAGE YESYES4.22STATUS INDICATOR OF RECLOSERS YES PARAMETERS YESYES POSITION OF THE EQUIPMENTS YESYES4.23ALLOWS STORAGE OPERATING EVENTS YES OPEN OR CLOSE YESYES LOSS VOLTAGE YESYES OPERATION CURRENT YESYES4.24REPORT FUNCTIONS YES EVENT REGISTRATION NUMBER SYSTEM 2048YES EVENT REGISTRATION NUMBER OF DIAGNOSIS 512YES EVENT OF PERFIL LOAD REGISTRATION 512YES REGSITER OF NUMBER OF SHOOTS YESYES REGISTER OF COUNTER OF FAILURES YESYES NUMER OF REGISTER WAVE FORM 32YES REGISTRATION FORM COMTRADE or software applicationYES 4.25REPORT FUNCTIONS ERROR IN THE MEASUREMENT BEFORE FAILURE 1% OR MINORYES AFTER FAILURE 3% OR MINORYES MEASSUREMENTS OF INSTANTANEOUS VALUES V,I,F,P,QYES ACTIVE AND REACTIVE POWER YESYES4.26 THE ConTROL MUST HAVE TO DISPLAY DATA AND ADJUSTMENT YESYES4.27COMMUNICATIONS PROTOCOL (READY FOR INTEGRATION WITH SYSTEMS SCADA) DNP 3.0YES4.28COMMUNICATION PORTS YES ETHERNET YESYES COMMUNICATION WITH PERSonAL COMPUTER RS232, ETHERNETYES COMMUNICATION READ DATA RS232, ETHERNET, RS485YES4.29OPTION be commanded remotely WITH RADIO MODEM OR GSM MODEM. YESYES EFFORTS TO SAFE OPERATION. YESYES INPUT AND OUTPUT NEEDED FOR THIS EFFECT. YESYES4.3ConFIURATION SOFTWARE ENVIROMENT WINDOWSYES SECURITY SYSTEM WITH PASSWORDYES INFORMATION DISCHARGE YESYES PROGRAMMING IN REMOTELY YESYES5AUXILIAR ENERGY FEEDER SYSTEM YES SYSTEM SINGLE PHASEYES INCLUDE AUXILIAR TRANSFORMER FOR ConTROL BOX YESYES5.01BATTERY COUNTRY TO INDICATECHINA MANUFACTURER TO INDICATELEOCH TYPE TO INDICATELEAD ACID NOMINAL VOLTAGE TO INDICATE12VX2 NUMBER OF UNIT OPERATING VOLTAGE TO FAILURES. 10 OR MORE24 MEASURING THE ConDITION OF THE BATTERY. YESYES BATTERY LIFE IN FAILURE OF LACK OF VOLTAGE. 48 HOURS48 INCLUDED IN THE CABINET OF CONTROL YESYES5.02SYSTEM OF CHARGE OF THE BATTERIES COUNTRY TO INDICATECHINA MANUFACTURER TO INDICATEBEJINAG AUXILIAR VOLTAGE 220 VACYES SYSTEM SINGLE PHASEYES COMPATIBLE WITH SPECIFIED BATTERIES YESYES INCLUDED IN THE CABINET OF CONTROL YESYES