Business Type:
Manufacturer/Factory,Trading Company
Business Range:
Ultraviolet Sterilizer, Water Descaling Equipment, Water Filter, Sand Filter, Water ..
Establishment:
2004
R&D Capacity:
OwnBrand, OEM
Terms of Payment:
LC, T/T, PayPal, WesternUnion
Main Markets:
North America, South America, Europe, Southeast Asia, Middle East, Africa, East Asia(Japan, South Korea), Australia, Domestic
OEM/ODM Service
Sample Available

Water Treatment Plant, Water Treatment, Water Softener manufacturer / supplier in China, offering 5000 Liter/Hour Automatic Water Softener with Duty / Standby, Contaminants and Chlorine Removed From Water by Activated Carbon Filter, Skid Installation 4000L/Hr Water Softener System Effectively Reduced Scale Build-up in Pipes and so on.

1
    YRS
General Supplier
Supplier Homepage Industrial Equipment & Components Environment Protection Device Water Disinfection System China 5000m3 Day Open Channel Ultraviolet Sterilizer System for Aquaculture Recirculating

China 5000m3 Day Open Channel Ultraviolet Sterilizer System for Aquaculture Recirculating

Get Latest Price
Min. Order / Reference FOB Price
1 Set US $5000.00/ Set
Local Area: Jian, Jiangxi, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal, WesternUnion
Certification: ISO9001, CE
Application: Water Treatment
Voltage: 220V

5000m3/day Open Channel Ultraviolet Sterilizer System For Aquaculture Recirculating
Open Channel Ultraviolet Sterilizer System Key components:
1. UV module;
2. Manual/automatic cleaning system;
3. Power cabinet;
4. Electronic ballast;
5. US imported UV lamps from LIGHTSOURCE with a power of 320W and lifetime up to 12,000 hours;
6. Air cooling system;
7. Electric wiring and accessories;
8. Support rack;
9. System capacity is 5,000 T/D
10. Automatic water level control, UV intensity monitor, central PLC controller from Siemens with color touch screen.

Typical ApplicationsWide range of clean / waste water treatmentLamp TypeLow-pressure, high-efficiency amalgam (monochromatic)Ballast TypeElectronic, high-efficiency, variable output (60~100% power)Input Power Per Lamp320, 550 Watts/pcLamp ConfigurationHorizontal, parallel to flow; Vertical to flow; 65°with the folowLamp Brand & OriginLightsource/Philip/Heraeus/Domestic brandModule Configuration8, 10 or 12 lamps per moduleLevel Control Device OptionsAutomatic Level Controller, Fixed weir or motorized weir gateWater Level Sensor1 electrode low water level sensor per channelUV Intensity Sensor1 UV detector for one sterilizer moduleWorking Temperature4~60ºC/39.2~140ºFWorking Pressure6 bar / 100psiEnclosure RatingsModule frame/Ballast EnclosureTYPE 6P (IP68) / TYPE 6P (IP67)All Other EnclosuresTYPE 4X (IP56)Ballast Cooling MethodConvection / Air conditioning / Forced air requiredInstallation LocationIndoor or outdoorModule frame/ChamberSS304/SS316, Internal finish - Ra(max)0.8umSleeve Cleaning SystemAuto-Cleaning SystemAutomatic Chemical/Mechanical (optional)Auto-Cleaning WW GelNon-corrosive, operator-friendly, food-gradeSleeve SpecQuartz sleeves, UV transmittance >92%ControllerPLC-based (Siemens/ Schneider PLC Standard Platform)Electrical RequirementsPower Supply220V, 50Hz (can be customized )Electrical CabinetWorking temperature 4~50ºC/39.2~122ºF, with power cord(2.5M)


Open Channel Ultraviolet Sterilizer System To customers details
Deatils:
01. What is the source of raw water to be treated?
--is it underground water or well water?or river water ,other source?
02. What is the capacity(m3/hour) you required for this sterilizer?
--most importANT requirement.
03. What will the treated water be used for?
--for human drinking or industry purpose?
04. What is the power supply in your country?
Open channel UV water sterilizer systems are mainly used at the municipal water/wastewater treatment plants for water recycling and effluent disinfection to ensure a better level of environmental protection.
UV disinfection is an effective and environmentally friendly alternative to the conventional chlorine effluent disinfection. Nowadays more than 15% of 2000 waste water treatment plants in North America have chosen the UV as the primary disinfection method. UV disinfection has proved its safety, reliability, efficiency, and economical characteristics over the years.
Open channel UV sterilziers GT series have been used for waste water, sewage water desinfection in order to achieve a lower envirionment pollution drainage.
Water quality factors that affect the disinfection efficiency and performance of the sewer UV water sterilizer system
1. Industrial waste water components of the incoming wale
2. The upstream treatment process and the chemical agents used
3. The UV light transmittance of the incoming flow
4. Content of the suspended matters
5. Particle size distribution

Design of the concise and lightweight bent frame
1. IP68 or equal grade of sealing protection. High-efficient secure multi-level sealing waterproof design.
2. The module adopts the push-in connectors with the less water resistance so as to guarantee the water incoming before disinfection and water discharge after disinfection.
3. There is little change in water level as to guarantee a stable sterilization effect.
4. It does not need any special tools to disassemble and assemble the disinfection module.

Attentions:
1.UV glasses must be worn for all the maintenance work
2.It is strictly prohibited to see ultraviolet lamp light with naked eyes in case that eyes hurt by ultraviolet light.
3.UV disinfection systems must have a good grounding to prevent electric shock accidents
4.Non-authorized electricians are not allowed to open the system control cabinet.
5.It is prohibited to change the configuration of the equipment' modulator tube
6.Non-specialty staff or non-professional technical personnel is strictly prohibited to disassemble the equipment in the event of accidents.
7.Before working on maintenance, first cut off the main power supply

System maintenance
1, UV lamp, quartz tube and sealing ring, the cleaning ring to replace or clean the above parts, first pull out the cable and the trachea of module and ballast wiring cabinet.

1.1 quartz tube cleaning

1.1.1 modules hanging out canals, placed in a flow or cleaning slot on the bracket, you can begin the manual pneumatic cleaning.
1.1.2 Diluted detergent or citric acid is available when cleaning, clean the dirt of quartz tube's outer wall with clean cloth.
2. Electronic ballast
2.1 disconnect control panel's power supply.
2.2 unscrew the two ends of the ballast electrical connection screws, remove the wire, loosen the screws. Remove the ballast, ballast.
2.3 replace the new ballast, connect the power and electricity.
3, air compressor - please refer to the air compressor manual
4, the water level sensor, please refer to the sensor instructions



Our services:We provide 24 hours online customer service.
Any inquiry about water treatment system, please feel free to contact me for further details!
Contact information:
Mobile phone: +86 13585066069
Alibaba website: http://yldwater.en.made-in-china.com
Official website: www.zgyld.com
Guarantee period:1 year
After-sale service:800-827-87-226