Business Type:
Trading Company
Business Range:
X ray machine, Ultrasound, Vet items, Dental items
Establishment:
2012
R&D Capacity:
ODM, OEM, Other
Terms of Payment:
LC, T/T, WesternUnion
Main Markets:
Southeast Asia, Middle East, Africa, Others
OEM/ODM Service
Sample Available

Hospital Equipment, Medical Equipment, Medical Supply manufacturer / supplier in China, offering Ysenmed One-Station Shopping Medical Hospital Equipment, Hospital Ysav200A Built-in Oxygen Air Blender Baby Neonatal Ventilator, Medical Ysvv500 Blood Locator Detector Finder Portable Vein Viewer and so on.

1
    YRS
General Supplier
Supplier Homepage Health & Medicine Medical Equipment Medical Diagnosis Equipment China 50kw Medical Hospital High Frequency X-ray Equipment

China 50kw Medical Hospital High Frequency X-ray Equipment

Get Latest Price
Min. Order / Reference FOB Price
1 Set Contact Supplier
Local Area: Guangzhou, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, WesternUnion
Classification: Imaging Diagnostic Equipment
Type: X Ray Equipment
Certification: ISO13485

20/50kw high frequency medical chest x-ray machine
(YSX200G/YSX500G)


YSX200G/YSX500G x ray machine is ok for all body parts checking.

Product Configuration:

No

Part Name

Qty

1

X-ray tube

1

2

Radiographic Table

1

3

Collimator

1

4

Microcomputer console

1

5

High-voltage generator,

1

6

High voltage cable

2

7

Vertical bucky stand

1

Standard Accessories:

No

Part Name

Qty

1

Lateral cassete holder with clamp

1

2

Bucky wall stand handgrip

1

3

Compression belt

1

4

Lead screen

1

5

Lead apron

2

6

Cassettes (8" x 10, 10" x 12", 12" x 15", 14" x 14")

4

7

Intensifying screen (8" x 10, 10" x 12", 12" x 15", 14" x 14")

4

Technical parameters of main components:


CONTENTS

YSX200G

YSX500G

Intermittent mode

100kV ,200mA,20kW

100kV ,500mA,50kW

Power Voltage

380V±10% 50Hz±10%

tube current

Radiography16mA~200mA

Radiography32mA~630mA

Output Voltage

Radiography 40-125KV step 1kV;

resistance power

less than 0.5Ω

Output power

20kW

50kw

Exposure Time

Radiography 0.0025s~6.4s adjustable

Radiography 3ms~6sadjustable

Nominal Frequency

30kHz

Speed of anode rotating

2800r/min

Anode heat capacity

140KHU

150KHU

Focus

Small focus:1.0mm Big focus:2.0mm

Length*width*height of bed surface

2000mmx750mmx690mmDeviation:±10mm

Horizontal movement distance of table

≥200mm

Vertical movement distance of table

≥900mm

Distance from table surface to film

50mm±2mm

Distance of vertical movement

770mm±10mm;

800mm-1100mm

Moving crosswise (left & right)

+180°~-180°deviation<±2°

Moving lengthways (along ground railway)

≥1300mm

600mm

Fixed beam filtration grid density

≥40 lines/cm.

grid ratio

10:01

Focus Distance

100cm

Cassette size