Lab Vacuum Glove Box with H2O, Vacuum Glove Box, Stainless Steel Vacuum Glove Box manufacturer / supplier in China, offering Laboratory Vacuum Glove Box with H2O&O2 Purification System, Nickel Ni Foam for Lithium Battery Cathode Materials, 4-30mm Thickness 10-130ppi Aluminum Al Foam Customized and so on.
Min. Order / Reference FOB Price | |
---|---|
1 Piece | US $1080.00/ Piece |
Local Area: | Xiamen, Fujian, China |
---|---|
R&D Capacity: | OEM, ODM, Other |
Payment Terms: | LC, T/T, PayPal |
Certification: | CE, ISO |
---|---|
Warranty: | 2 Years |
Trademark: | TMAX |
5V12A 8 Channel Battery Tester for Pouch Cell/Polymer Battery
1. This tester can analyze polymer and cylindrical batteries from 0.1mA to 12A, up to 5V.
2 The battery tester system provides most applications in battery testing fields such as electrode materials research, battery performance test, small-scale battery formation, capability grading, battery pack testing and etc.
Specifications.Items
Values
Input AC
AC 220V/110V ±10% / 50Hz
Input power
851 W
Resolution
AD:16bit;DA:16bit
Input impendence
≥1MΩ
CV output range
25mV~5V
Min discharge voltage
1.0V for universial holder,1.5V for 2m cable
Voltage
Accuracy
± 0.05% of FS
Stability
± 0.05% of FS
Output range/channel
Range1: 5mA-1A; Range2: 1A-12A
Accuracy
± 0.05% of FS
Current
CV cut-off current
Range1: 2mA; Range2: 24mA
Stability
± 0.05% of FS
Output power/channel
60
W
Power
Stability
± 0.1% of FS
Current rsponse time
Max rising time:1ms
Time
Working step time
≤(365*24)h/step Time format-00:00:00.000(h,m,s,ms)
Min data record interval:100ms
Data record conditions
Min voltage change:10mV
Data record
Min current change:Range1: 2mA; Range2: 24mA
Frequency
10Hz
Charge modes
CC,CV,CCCV,CP
Charge
Cut-off condition
Voltage,Current,Time,Capacity,-△V
Discharge modes
CC,CP,CR,CV
Discharge
Cut-off condition
Voltage,Current,Time,Capacity,-△V
Charge
CC,CP
Discharge
CC,CP
Min pulse width
500ms
Pulse
Pulse counts
Up to 32
Chg and Dischg switch
Supported
Cut-off condition
Voltage,Time
DCIR
Supported
Max cycles
65535
Cycle
Max steps
254
Cycle nest
3
Power-off data protection
Off-line operation mode
Protection
Safety protection
User-defined protection conditions, such as upper and lower limited current/voltage, delay time, temperature, etc.
Channels feature
Independent pairs of closed loop for constant
Channels control mode
Independent control
Data acquisition method
Kelvin connection
Noise
<85dB
Database
MySQL
Communicatin
TCP/IP
Operating system
Windows 7/8/10 64 bit
Data export
EXCEL,TXT,CSV,PDF,Plot/Graph
Disk drive
500GB
Communication port
Ethernet port
Leak Current
0.0000005mA
Channels per unit
8
Operation and storage environment requirement
Items
Values
Operation environment humidity
≤70% RH(no moisture condensation)