Business Type:
Manufacturer/Factory
Establishment:
2012
R&D Capacity:
ODM, OEM, Other
OEM/ODM Service
Sample Available

Current Transformer, Split Core Current Transformer, Split Current Transformer manufacturer / supplier in China, offering Waterproof Outdoor Split Core CT Current Transformer for Power Meter, 500/5A Split Core CT Current Transformer, 2500 AMP Accu CT Split Core Current Transformer 333mv Sensor and so on.

1
    YRS
General Supplier

China 61850 Conformance Test Set

Get Latest Price
Min. Order / Reference FOB Price
10 Set Contact Supplier
Local Area: Chaoyang, Liaoning, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Type: Software
Application: Test Software
Software Function: Monitoring+Control
GF4600 - IEC61850 conformance testing system is in the electric power system in intelligent power grid, intelligent substation test to research and development of test tool. Conform to the international IEC61850 and national standard DL/T860 technical requirements. GF4600-IEC61850 conformance testing system uses friendly interactive graphical interface, easy to use flexible, which is based on the power system to engage in scientific research, measurement, automation, protection professional engineer development tools, users need to grasp the concept of a few IEC61850, he can use the test tool. The test system can fully comparable with the Netherlands KEMA IEC61850 conformance testing software, and better compatibility.

> IEC 61850 Protocol Analyzer
> IEC 61850 Client Simulator
> IEC 61850 GOOSE Simulator
> IEC 61850 SCL Checker
> IEC 61850 SCL Multi IED Simulator
> IEC 61850 MU Test
> IEC 61850 IED Test
> IEC 61850 Double Network Redundancy Test
FunctionsTEST SOFTWARE MODELSERIAL NUMBER: 1
IEC61850MMS CLIENT SIMULATIonSERIAL NUMBER: 2
IEC61850MMS AUTOMATED TESTINGSERIAL NUMBER: 3
SIMULATION TERMINAL (MMS SERVER) EMULATION SOFTWARESERIAL NUMBER: 4
GOOSE PUBLISH SIMULATIonSERIAL NUMBER: 5
GOOSE SUBscriptION SIMULATIonSERIAL NUMBER: 6
SMV PUBLISH SIMULATIonSERIAL NUMBER: 7
SMV SUBscriptION SIMULATIonSERIAL NUMBER: 8
MOTION TESTING SOFTWARE MODELSERIAL NUMBER: 9
MNETWORK COMMUNICATION MESSAGE ANALYSIS SOFTWARESERIAL NUMBER: 10
TIME SYNCHRonIZATION SNTP SIMULATIonSERIAL NUMBER: 11


Intelligent substation has widely adopted IEC 61850 standard communication, the standardization of information model is the basis for intelligent substation equipment (or system) to achieve IEC 61850 communication. This module can test if the information model meet the requirements of DL/T860 standard, national network and related model specifications. It can test and control unit model, protection unit model, econometric model, condition monitoring model. It is selectable to test according to IEC61850-6 SCL grammatical rules, IEC61850-7 logic nodes and common data, the national network model standards and custom models.
According to 61850-10 rules, this software is to confirm whether the tested product meet the standards on consistency requirements.
Simulated client IEC61850, testing intelligent electronic devices IED (the control unit, the protection unit etc.). Testing the IED directory tree, IED associated equipment, servers, logical devices, logical nodes and data, data sets, replacing, reporting, setting the group control, recording, controlling and other functions.
Simulated client IEC61850, automatic testing intelligent electronic devices IED (the control unit, the protection unit etc.), according to predetermined test (IEC61850-10), exporting the test results to a variety of file formats (word, pdf, html, xml).
Can automated test based on ICD / CID files.
Simulated server IEC61850, testing back-office systems and far motivation systems of intelligent substation. According IED and ICD files, simulating MMS server to achieve the directory tree, logical devices, logical nodes, data reading and writing, data sets, valuation, reporting, replacing and other functions.
Simulation issue event message IEC61850-GOOSE, testing if the operation of the IED is correct. You can configure Priority, Dest MAC Address, VLanID, Source MAC Address, APPID, timetoLive, gocbRef, datSet, goID, test, confRev, numEntries, GOOSE data formats and other parameters.
Simulation receive event message IEC61850-GOOSE, testing if the issued GOOSE of the digital device IED is correct.
Recognition IEC61850-GOOSE message, setting the message format, displaying Goose in graphical data
Simulation issue sampled value message IEC61850-9-1 or IEC61850-9-2 (LE), testing the digital device IED. You can configure Priority, Dest MAC Address, VLanID, Source MAC Address, APPID, datSet, svID, confRev, SMV data formats and other parameters.
Simulation receive sampled value message IEC61850-9-1 or IEC61850-9-2 (LE), testing if the issued message of digital merger unit is correct.
Recognition IEC61850-9-2 (LE) message, setting the message format, displaying SMV in graphical data
Software test if the CID / ICD files and intelligent substation IED device implementation model is consistent, simple and flexible, the features are following:
1) Use the XML parser reads and parses the CID / ICD files and extract model information;
2) import the IP address of MMS server at the interface, use the MMS client mode to communicate with the tested IED device, read layers of the model information of the tested IED device online by ACSI model service
3) Compared the information from 1) and 2), you can check if the CID / ICD files and intelligent substation IED device implementation model is consistent.
Monitoring network interfaces, in-depth analysis of network protocol message such as MMS, goose, SMV etc., showing the real MMS interaction.
Monitoring substation network, capturing and analyzing IEC 61850 information, and can be used for acceptance testing, interoperability testing, conformance testing, error logs and network performance monitoring, support IEC 61850 products development.
Testing 61850 time synchronous with SNTP service.