Business Type:
Manufacturer/Factory
Establishment:
2012
R&D Capacity:
ODM, OEM, Other
OEM/ODM Service
Sample Available

Current Transformer, Split Core Current Transformer, Split Current Transformer manufacturer / supplier in China, offering Waterproof Outdoor Split Core CT Current Transformer for Power Meter, 500/5A Split Core CT Current Transformer, 2500 AMP Accu CT Split Core Current Transformer 333mv Sensor and so on.

1
    YRS
General Supplier
Supplier Homepage Instruments & Meters Electronic Instrument Clamp Meter China AC Double Clamp Digital Phase Angle Tester

China AC Double Clamp Digital Phase Angle Tester

Get Latest Price
Min. Order / Reference FOB Price
2 Set US $200.00/ Set
Local Area: Chaoyang, Liaoning, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Brand: Gfuve
Customized: Customized
Certification: CE, ISO, RoHS
GF211B AC double clamp Digital Phase Angle Tester
Application
GF211B double clamp phase volt-ampere meter is a multi-functional portable instrument. It can measure not only alternating voltage, but also alternating current. Its important function is to measure phase angle between two voltages, between two current or between voltage and current. The current signal is obtained by the clamp current transformer without cutting off current wire. It can discern inductive circuit and capacitive circuit; Can directly read differential protection phase among every unit of CT; Can check connection of transformer; Measure three way voltage phase sequence; Can check whether the meter connection is right or not; Can evaluate the running speed of electric kWh meter. It has high resolution of current, so can be used as a leakage current meter. It is an ideal choice for electric power bureau, factories, mine, petroleum -chemistry enterprises, metallurgy factories and so on.
Specifications
2.1 Scale
2.1. 1 Phase: 0-360°
2.1. 2 AC Voltage: 500V
2.1. 3 AC Current: 200mA / 2A / 10A
2.2 Fundamental error (under standard operating environment)
2.2.1 Standard Condition
2.2. 2 Phase accuracy 1.0% FS
2.2.3 Voltage accuracy
2.2.4 Current accuracy
2.3 Input impedance:
2.3. 1 1MΩ When measure voltage
2.3. 2 input voltage impedance>120KΩ When measure phase
2.4 operation condition
2.5 additional error
2.5. 1 When measure phase angle, the voltage and the current are in the range of the operating conditions, the additional error is less than the fundamental error.
2.5. 2 When measure current, the error LED by wires away from center of clamps is less than the fundamental error.
2.6 Safety specification
2.6. 1 Resistance to voltage
The meter can resist 1000V (AC sinewave, 50Hz or 60 Hz) for 1 minute both between the meter circuit and the meter case; Between input joint U1 and U2 can resist 500V(AC sinewave, 50Hz or 60 Hz) for 1 minute.
2.6. 2 Insulation resistance
The resistance both between the meter circuit and the meter surface and between the terminals U1 and U2 is greater than 100MΩ .
2.7 Power supply Two 9V batteries.
2.8 Size and Weight: 85mmx 167mmx 35mmm 0.5Kg

TemperatureMoistureWave FormFrequencyWire PositionPhase measurementvoltagecurrent23±5degrees<65%Sine wave Distortion ≤1%50± 2Hz, 60± 2Hzcenter of clamp100V± 25V1A±0.2A

ScaleAccuracyResolution200V1.0FS0.1V500V1.0FS1V

ScaleAccuracyResolution10A2.0FS10mA2A2.0FS1mA200mA2.0FS0.1mA

TemperatureMoisturePhase measurementvoltage rangeCurrent range0±40degrees≤80%3V-500V0.01A-10A

NoNameNumber1Double clamp phase volt-ampere meter12Clamps 10A23Clamp wire24Voltage wire25User's manual16Certification of quality17Box1