Industrial Plug Socket, Plug Socket, Industrial Plug manufacturer / supplier in China, offering PC Plug Socket Coupling, Hand Crimping Tool for Non-Insulated Terminal 10-120mm, AC Contactor for Motor Control and so on.
Min. Order / Reference FOB Price | |
---|---|
100 Piece | US $15.00/ Piece |
Local Area: | Beijing, China |
---|---|
R&D Capacity: | OEM, ODM, Other |
Payment Terms: | LC, T/T, PayPal, WesternUnion |
Type: | Power Source Arrester |
---|---|
Structure: | Protective Gap |
Installation: | Parallel Arrester |
Application
TSU1 surge protector is mainly applied to limiting amplitude value of transient over voltage, absorbing, consuming, discharging surging current energy in the electric wiring of AC 50/60Hz, rated working voltage 230V, surging through flow capacity not more than 50A.
It is used in the occasion of higher type of over voltage which can make the protected electrical component transferring from one type of over voltage to another lower type of over voltage.
It is adapted for composing combined electrical equipment with other module terminal electrical equipment so that it can increase installation types and expand range of using, or further step down over voltage on using terminals to protect TV set, hi-fi sound and such kinds of electrical appliances or the facilities like computer, microcomputer.
Protector applies to power utilization for household and the similar places, facilities for inputting circuit in the thunder direct stroke or protecting from the damage of the surging current caused by outdoor arrester. The products comply with IEC61643.
Specification
Number of Poles1P, 1P+N, 3P, 3P+NThermal Setting In (A)6, 10, 16, 20, 25, 32, 40Tripping CharacteristicB, SRated Voltage AC Un(V)240Minimum Operating Voltage UBmin(V)100Mechanical Electrical Endurance20000/10000Terminal Capacity Flexible/rigid Cable(mm2)Bottom terminal: 16-25Nuisance Tripping Resistance250A 8/20μsAmbient Temperature (ºC)-5~+55Weight (g)350
Class of Protectionclass Bclass Cclass DRated Current (kA)40-6515-408-15Reaction Time (tr)< 25ns< 25ns< 25nsProtection Voltage Level (Up)< 2.0kV< 1.8kV< 1.5kVMax persistent Working Voltage (Ue)275/440VAC275/440VAC275/440VACNominal Discharge Current (In)25kA
(10/350)μs10kA,15kA
(8/20)μs2.5kA,5kA
(8/20)μsMax Discharge Current (Imax)50kA
(8/80)μs30kA,40kA
(8/20)μs5kA,10kA
(8/20)μsMax Reserve Protection Fuse250A gl125A gl63A glShort Circuit Tolerance10kA10kA10kAWorking Ambient Temperature Range-40ºC~70ºCRated Operating Voltage (V)230, 400