Nesting software, nest software, cutting software manufacturer / supplier in China, offering NESTWIN Automatic Nesting Software for CNC sheet metal processing, YZ50/30 digital display motor-driven stress direct shearing apparatus, YZW30/50/100/200 computer-controlled rock stress direct shear apparatus and so on.
Min. Order / Reference FOB Price | |
---|---|
1 set | US $1272.00/ set |
Local Area: | Shijiazhuang, Hebei, China |
---|---|
R&D Capacity: | OEM, ODM, Other |
Payment Terms: | LC, T/T, PayPal |
Certification: | ISO9001, CCC, CE |
---|---|
Protection: | IP 20 |
Installation: | Wall-mount, Frame-mount |
Product Description
Unbalance compensationfor harmonics or reactive power first;The protection level of the system reaches IP20;Can withstand 2.5 times overload of 10ms.The CT can be installed on the load side or the grid side according to the user's choice. The device can be automatically compatible with the CT phase sequence.By setting, you can choose whether to compensateOther basic functionsBalance the three-phase current of the system to avoid single-phase overload of the transformer and improve the effective use capacity;Harmonic filtering functionUp to 51 harmonics can be filtered out;Within the capacity range, the effective filtering ability of the target harmonics reaches 97%;Select and filter all the harmonics within 51 times at the same time, and set the filtering ratio of each harmonic;;With fast harmonic compensation, response time ≤5ms;Reactive compensation functionWith reactive power compensation capability, that is power factor adjustment capability;Provide two reactive power compensation modes : 1) constant reactive power mode; 2)constant power factor mode;Rated compensation conventional capacity50A80A100A120A150A200ARated overload capacity1.2 times rated current /1 min, 2.5 times rated current /10msWiring modeThree-phase four-wire system (three-phase three-wire system can be customized) under AC380V Voltage class Three-phase three-wire system under AC690V Voltage classCooling methodAir coolingAmbient temperature40°C , up to 55°C , 2%/K over-temperature automatic deratingParallel operationSupport multi-machine parallel connection, can not equal capacity parallelCommunications protocolRS-485, Modbus-RTU communication protocolRated operating voltageAC380V±20%AC690V±15%Air cooling requirements (full load)≥330m3/h≥600m3/h≥1000m3/h≥1200m3/h≥1200m3/h≥1000m3/hNoise level≤ 60dB≤ 65dBHarmonic filtering range2-51 timesFunction setCombination of harmonic compensation, reactive compensation, unbalance compensation and free compensation with priorityDry contactOne input contact: control switch machine; three output contacts: running power failureAltitude≤ 3000 mVoltage classAC380V±20%,AC690V±20%Rated operating frequency50Hz±5%Response time< 5msTransformer installation locationPower side / load sideDimension(mm) Wallmount400x190x570450 x 200 x 620480 x 270 x 707 (width x depth x height) Drawer530x550x190530 x 550x190475 x 600 x 270550x600x270Weight (kg)25 kg35 kg 70 kg70 kg62 kgProtection class Standard IP20CertificationType test report of National Electronic Control and Distribution Equipment Quality Supervision Center, China Taier Laboratory Inspection Report
Packaging & Shipping
By Sea or By air is all availableAfter Sales Service
1) Commissioning/Debugging On-Site;
2) Commissioning/Debugging Remote Online;