Nesting software, nest software, cutting software manufacturer / supplier in China, offering NESTWIN Automatic Nesting Software for CNC sheet metal processing, YZ50/30 digital display motor-driven stress direct shearing apparatus, YZW30/50/100/200 computer-controlled rock stress direct shear apparatus and so on.

1
    YRS
General Supplier

China AC380V400V50Hz ACTIVE HARMONIC FILTER

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $1280.00/ Piece
Local Area: Shijiazhuang, Hebei, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Certification: ISO9001, CCC, MA AL CNAS
Protection: Shock Resistance
Installation: wall mounted, frame-mounted, cabinet

Product Description

The WBAPF three-level series active filter can directly or indirectly measure the current injected into the grid by a non­linear load through a connected external current transformer. The detection and operation of harmonic and reactive compensation are performed in the digital control unit. The active filter generates a compensation current that cancels the harmonic components and the load reactive current, so that there is only a fundamental current in the grid. The active filter is able to adapt the changes in the magnitude of the load and system harmonic content in real time so that it can be treated at any time

Product Features

Harmonic filtering functionUp to 51 harmonics can be filtered out;Within the capacity range, the effective filtering ability of the target harmonics reaches 97%;Select and filter all the harmonics within 51 times at the same time, and set the filtering ratio of each harmonic;;With fast harmonic compensation, response time ≤5ms;Reactive compensation functionWith reactive power compensation capability, that is power factor adjustment capability;Provide two reactive power compensation modes : 1) constant reactive power mode; 2)constant power factor mode;Unbalance compensationBalance the three-phase current of the system to avoid single-phase overload of the transformer and improve the effective use capacity;Other basic functionsThe CT can be installed on the load side or the grid side according to the user's choice. The device can be automatically compatible with the CT phase sequence.By setting, you can choose whether to compensatefor harmonics or reactive power first;The protection level of the system reaches IP20;Can withstand 2.5 times overload of 10ms.

Product Model

Product Parameters

Rated compensation conventional capacity50A80A100A120A150A200ARated overload capacity1.2 times rated current /1 min, 2.5 times rated current /10msWiring modeThree-phase four-wire system (three-phase three-wire system can be customized) under AC380V Voltage class Three-phase three-wire system under AC690V Voltage classCooling methodAir coolingAmbient temperature40°C , up to 55°C , 2%/K over-temperature automatic deratingParallel operationSupport multi-machine parallel connection, can not equal capacity parallelCommunications protocolRS-485, Modbus-RTU communication protocolRated operating voltageAC380V±20%AC690V±15%Air cooling requirements (full load)≥330m3/h≥600m3/h≥1000m3/h≥1200m3/h≥1200m3/h≥1000m3/hNoise level≤ 60dB≤ 65dBHarmonic filtering range2-51 timesFunction setCombination of harmonic compensation, reactive compensation, unbalance compensation and free compensation with priorityDry contactOne ut contact: control switch machine; three output contacts: running power failureAltitude≤ 3000 mVoltage classAC380V±20%,AC690V±20%Rated operating frequency50Hz±5%Response time< 5msTransformer installation locationPower side / load sideDimension(mm) Wallmount400x190x570450 x 200 x 620480 x 270 x 707 (width x depth x height) Drawer530x550x190530 x 550x190475 x 600 x 270550x600x270Weight (kg)25 kg35 kg 70 kg70 kg62 kgProtection classStandard IP20CertificationType test report of National Electronic Control and Distribution Equipment Quality Supervision Center, China Taier Laboratory Inspection Report

An Actual Case of the AHF/APF:

Before the APF/AHF switch on: There are harmonic and reactive losses in the grid, resulting in power quality problemsAfter the APF/AHF switch on: generating reverse harmonic current and reactive current, dynamically compensating for harmonics and reactive power, guaranteed power quality



Packaging & Shipping




After Sales Service

1) Debugging and Commissioning on Customer's site;
2) online Romote Commissioning and Debugging;
3) Spare parts and CT available;