PSA Series Air Driven Gas Booster
Air Driven Gas Boosters involve PSA Series are another type of high pressure reciprocating pumps used for gas boosting, driven of compressed shop air. PSA Seires are single acting, single air head driven type. Compared with STA series gas booster, they have smaller driven piston.
PSA Series Gas Boosters are suitable for the oil free compression of air and industrial gases like Nitrogen, Helium as well as flammable and risk gases like Hydrogen, Oxygen and natural gas. Air drive pressure from 1bar(14.5psi. ) to 8bar(116psi. ). Provide for operating pressures up to 48Mpa.
PSA Series Oxygen Booster is specially designed for oxygen gas, including industrial oxygen gas, breathing air/oxygen, medical oxygen etc. With stainless steel pressurizing chamber and stainless steel end cover.
PSA Series oxygen booster is mainl used for filling up oxygen cylinder.
Key features
No electricity required. Safe operation, ex-proof
More appropriate ratios for meeting higher flowrates and faster fill times
No airline lubricator required
Hydrocarbon free-seperation between air drive and gas booster sections
Suitable for most gases
Built-in cooling
High quality seals, long life service available
All components in contact with the gas are made of aluminium or resp. Stainless steel
Wide range of models. There are six models for your option
Standard and custom systems available
Reliable, easy operation and maintenance
Technical parameters
Type
Pressure
ratio
Min. gas inlet pressure
PA ( bar )
Max. gas
Inlet
pressure
PA ( bar )
Max.gas
outlet
pressure
PB ( bar )
Formula to
calculate gas
outlet pressure
PB
Connection:
Gas Drive /
Gas Inlet /
Gas outlet
Max. flow at air drive pressure of 6 bar (L/min)
PSA02
2:1
2.1
16
16
2PL
G1/2 /
NPT 3/8/ NPT 3/8
206(at PA of 6 bar)
PSA06
5:1
4.3
48
48
6 PL
G1/2 /
NPT 3/8/ NPT 3/8
84(at PA of 8 bar)
PSA15
15:1
6.8
120
120
15 PL
G1/2 /
NPT 1/4/ NPT 1/4
196(at PA of 20 bar)
PSA25
25:1
12.5
200
200
25 PL
G1/2 /
NPT 1/4/ NPT 1/4
48(at PA of 20 bar)
PSA40
40:1
18.5
320
320
40 PL
G1/2 /
NPT 1/4/ NPT 1/4
49(at PA of 20 bar)
PSA60
60:1
31
480
480
60PL
G1/2 /
NPT 1/4/ NPT 1/4
61(at PA of 40 bar)
Note: PL: air drive pressurePA: gas inlet pressurePB: gas outlet pressure