Flow Sensor, Ultrasonic Flow Sensor, Portable Flow Meter manufacturer / supplier in China, offering Hot! ! High Accutacy Portabl Ultrasonic Flow Sensor, Electric / Pneumatic Ball Valve Switch (on-off) , Control Valve (4~20mA control) , Q641 Pneumatic on-off Ball Valve (with solenoid valve, limit switch), Gas Flow Controller-Gas Flow Measurement-Digital Gas Flow Meter and so on.
Min. Order / Reference FOB Price | |
---|---|
1 Piece | US $500.00/ Piece |
Local Area: | Xingtai, Hebei, China |
---|---|
R&D Capacity: | OEM, ODM, Other |
Payment Terms: | LC, T/T, PayPal |
Environmental Temperature: | - 30 Degrees C ~ + 60 Degree C |
---|---|
Medium Temperature: | - 20 Degree C ~ + 350 Degree C |
Atmospheric Pressure: | 106kpa~70kpa |
Vortex Flow Meter
1. Product DescriptionLUGB series Vortex flow meters are designed for measuring the volume/mass flow of liquids, gases and steam based on Karman vortex principle.Application range(1) Gas; (2) Liquid; (3) SteamMeasured Value Primary measured valueFlow RateSecondary measured valueVolume flow ; (Pressure and Temperature is available for model with compensation)
DesignFeatures Modular constructionThe measurement system consists of a flow sensor and a signal converter. It is available as compact and as separate version.Compact version converterN Type: Pulse output without local displayA Type: 4-20mA Output without local displayB Type: Local Display; Lithium Battery Power; No Output (Battery Part No.:
ER26500)C Type: Local Display; 24V DC Power; 4-20mA
Output;
Optional Function:Backup Power Supply: Lithium BatteryModbus RS485Pulse OutputConnection Flange: DN15-DN300Wafer: DN15-DN300Measurement RatioStandard - 10:1
Reference conditionsFlow conditions similar to EN 29104Medium: Water / GasElectrical conductivity: ≥ 300 μS/cmTemperature: +10...+30°C / +50...+86°FInlet section: ≥ 10 DNOperating pressure: 1 bar / 14.5 psigFlow Meter Accuracy For Liquid: 1.0% of rate
For Gas and Steam: 1.5% of rate
Temperature Process temperatureT1 Level: -20...+70°CT2 Level: -20...+250°CT3 Level: -20...+350°CAmbient temperature
(all versions)Standard (with aluminum converter housing):-10…+55°CStorage temperature-20...+70°Pressure EN 1092-1DN200…DN300: PN10DN100…DN200: PN 16DN15…DN80: PN 25Other pressures on requestASME B16.51/2"...8": 150 lb RFOther pressures on requestJIS1/2"...8": 10 KOther pressures on request
InstallationTake care that flow sensor is always fully filledFor detailed information see chapter
"Cautions for Installation"Flow directionForwardArrow on flow sensor indicates flow direction.Inlet run≥ 10 DNOutlet run≥ 5 DN
Sensor housingSS304Other materials on requestFlangesSS304Other materials on requestConverter HousingStandard: polyurethane coated die-cast aluminum
Process connectionsFlange EN 1092-1DN15...300 in PN 6...25ASME1/2"…12" in 150 lb RFJIS1/2"…12" in 10...20KDesign of gasket surfaceRF Other sizes or pressure ratings on requestWaferDN15…DN300
Nominal DiameterLiquidGas(mm)(in.)Flow (m3/h)Flow (m3/h)151/2"1.2 to 6.25 to 25203/4"1.5 to 108 to 50251"1.6 to 1610 to 70401-1/2"2.5 to 2522 to 220502"3.5 to 3536 to 320652-1/2"6.5 to 6550 to 480803"10 to 10070 to 6401004"15 to 150130 to 11001255"25 to 250200 to 17001506"36 to 380280 to 22402008"62 to 650580 to 496025010"140 to 1400970 to 800030012"200 to 20001380 to 11000
3. Model and SelectionTable 1: Model Selection Guidance for Vortex FlowmeterModel Suffix Code DescriptionLUGB- Connection1Flange2WaferFluid0Gas1Liquid2SteamDiameter Three Digitals; for example:
010: 10 mm; 015: 15 mm;
080: 80 mm; 100: 100 mmStructureZCompact TypeFRemote TypeConverterNNo display; 24V DC; Pulse OutputANo display; 24V DC; 4-20mA OutputBLocal display; Lithium Battery Power; No outputC1Local display; 24V DC Power; pulse output & RS485
Optional backup power: Lithium BatteryC2Local display; 24V DC Power; 2 - wire 4-
20mA Output
Optional backup power: Lithium BatteryC3Local display; 24V DC Power; 3 - wire 4-
20mA and pulse Output, with RS485
Optional backup power: Lithium BatteryDTemperature / Pressure Compensation
D1_1: 24V DC Power, LCD+pulse+2wire 4-20mA;
D1_3: battery+DC24V power, LCD+ pulse,
3-wire 4-20mA, Modbus RS485
D1_4: DC24V power, 2-wire 4-20mA + Hart;
Explosion Rating NSafety Field without ExplosionEExdIIBT6Flange Standard -DXXDXX: D06, D10, D16, D25, D40
D06: DIN PN6; D10: DIN PN10
D16: DIN PN16; D25: DIN PN25
D40: DIN PN40-AXAX: A1, A3, A6
A1: ANSI 150#; A3: ANSI 300#
A6: ANSI 600#-JXJX: J1, J2, J4
J1: JIS 10K; J2: JIS 20K; J4: JIS 40K-WFWafer Connection; Mating Flange included.Fluid Temperature-T1-20...+70°C-T2-20...+250°C-T3-20...+350°CSpecial requirements NIf no special requirements.