Single point load cell
Dimension:
1, Customized is accept
2, Simple structure, convenient to install and maintenance
3, Good long-term stability
4, Each product have a track no
MODEL
HMD7001
COMPREHENSIVE ERROR
0.02
0.03
OUTPUT SENSITIVITYmV/V
2.0±0.25%
NonLINEARITY %F.S.
±0.02
±0.03
REPEATABILITY %F.S.
0.02
0.02
HYSTERESIS%F.S.
±0.02
±0.03
CREEP(30min) %F.S
±0.02
±0.03
TEMP. EFFECT ON ZERO %F.S/10
≤0.002
≤0.003
TEMP. EFFECTOUTPUT%F.S/10
≤0.002
≤0.003
ZERO OUTPUT %FS
±1
±1
INPUT RESISTANCE Ω
400±30
OUTPUT RESISTANCEΩ
350±3
INSULATION RESISTANCE MΩ
≥5000
EXCITATION VOLTAGE VDC/AC
512
OPERATION TEMP. RANGE
-30+80
OVERLOAD CAPACITY %F.S.
150
CAPACITY
100-2000kg
IP67